If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual INTERMATIC SG160 MODULAR. We hope that this INTERMATIC SG160 MODULAR user guide will be useful to you.

Lastmanuals help download the user guide INTERMATIC SG160 MODULAR.


Mode d'emploi INTERMATIC SG160 MODULAR
Download
Manual abstract: user guide INTERMATIC SG160 MODULAR

Detailed instructions for use are in the User's Guide.

[. . . ] H. ) DO NOT CONNECT WITHOUT SECURING POWER FROM THE DISTRIBUTION PANEL. I. ) J. ) CHECK TO ENSURE THAT ALL CONNECTIONS ARE CORRECT AND SECURE BEFORE ENERGIZING. DO NOT ENERGIZE WITH DOOR OPEN. KEEP THIS MANUAL IN A SAFE DRY PLACE FOR FUTURE REFERENCE. APPLICATION or TECHNICAL ASSISTANCE Contact Intermatic at 1-800-391-4555 or on the web at www. intermatic. com 12. 94" (329mm) 14. 75" (375mm) 15. 50" (394mm) (ALL MODULAR SG MODELS) After determining a position to mount the device that will minimize the length of the connecting wires, drill a hole in the cabinet for the conduit to run the wires from the distribution panel to the connecting lugs inside the SPD. [. . . ] RED LED: If a problem develops with the internal monitoring circuitry or, in the unlikely event that there should be a loss or reduction in the protection elements, the RED LED over the words "SYSTEM FAULT" will illuminate. YELLOW LED: If the Yellow LED illuminates, at any time, there could be a hazardous system wiring fault. The YELLOW LED does not indicate a suppressor failure; however, it does signal that there maybe dangerous Neutral to Ground Voltages present. Consult with a qualified electrician to verify the integrity of the installation's wiring. (Not present on Delta Configurations. ) AUDIBLE ALARM: The Alarm will sound if protection should be lost on either the L-N or L-G Modes. Control of the Alarm is managed with a switch located on the front panel next to the Alarm. The switch has three (3) settings: Up (momentary only) for testing, which will sound the alarm. Center, this is the Disable position and turns the Alarm off. Down, this Enables the Alarm and sets it for constant monitoring. COUNTER: The Surge Counter will show the number of transient events that the suppressor encounters. Control of the Surge Counter is managed with a switch located to the left of the counter display. The switch has three (3) settings: Up, (momentary only) for RESET. Center, this is the ENABLE position and turns the Counter on and sets it for constant monitoring. Down, (momentary only) this tests the Counter and will increase the count by 1 increment each time it is activated. TROUBLE SHOOTING GUIDE There is little or no trouble shooting required for this Series of products. However, there are situations where there could arise a scenario where the Front Panel Diagnostics does not operate as intended. In such a case follow these directions. . . PROBLEM: No Front Panel Diagnostics or improper operation: Ensure that SPD unit is properly connected to the AC Service Panel and that all connections are secure. Confirm that the breaker in the AC supply panel is in the ON position. If problem still persists: TURN OFF BREAKER, open the SPD door and verify that all VISIBLE cable connections are properly secured, no loose wires. This is especially critical for the connectors on the Sensor Cable as they interface with the SG modules. When the SG module is properly connected the 2 Green LEDs should be illuminated and the center Yellow LED (not applicable on Delta Units) should not. [. . . ] Condition of ALL Connection Cables and Terminations INSTALLATION, SERVICE OR REMOVAL OF THIS DEVICE SHOULD ONLY BE PERFORMED BY A QUALIFIED LICENSED ELECTRICIAN. ANY ALTERATIONS, TAMPERING, MISUSE OR UNAUTHORIZED REPAIRS OF THIS PRODUCT WILL VOID ITS ORIGINAL FACTORY WARRANTY. IMPORTANT DATA DATE PURCHASED: DATE INSTALLED: DEALER/DISTRIBUTOR'S NAME AND ADDRESS: CONTACT(S): PHONE #: CONTRACTOR'S NAME AND ADDRESS: FAX #: PHONE #: FAX #: PRODUCT IN. ORMATION MODEL #: MANUFACTURED DATE: SERIAL #: Page: 7 FIVE YEAR PRODUCT WARRANTY WARRANTY AND LIMITATION OF LIABILITY If within five (5) years from the date of purchase, this surge protection device fails due to defect in material or workmanship, Intermatic Incorporated will repair or replace it free of charge. The warranty does not apply to: (a) damage caused by accident, abuse, mishandling, dropping; (b) units which have been subject to unauthorized repair, opened, taken apart; (c) units not used in accordance with directions; (d) damages exceeding the cost of the product. Some states do not allow a limitation of damages, so the foregoing limitations may not apply to you. This warranty gives you specific legal rights and you may also have other rights, which vary, from state to state. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC SG160 MODULAR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual INTERMATIC SG160 MODULAR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag