[. . . ] MODEL: T21004R
IMPORTANT:
IN RAINPROOF (TYPE 3R) ENCLOSURE FOR INDOOR/OUTDOOR USE
The short circuit rating of this panel is 10000 symmetrical amperes.
CLASS CTL DISTRIBUTION/CONTROL PANEL WITH TIME SWITCH
LR3730 UL 508 UL1563
This control panel must be installed according to the National Electrical Code (including article 680) or Canadian Electrical Code (including section 68) and local code requirements. This installation is subject to the approval by the local inspection authority. [. . . ] When panel is outdoors, a LISTED rainproof cover must be installed over the wiring device in the side knockouts. If this enclosure is used for direct conduit connection to a wet-niche or no niche luminaire, one of the connection kits listed below in Note 5 must be used. This control should not be connected to any equipment which would cause bodily injury or property damage should it be activated unexpectedly. After wiring, install front panel over wiring compartment and close unused breaker openings with filler plates. WIRING INFORMATION - COPPER CONDUCTORS ONLY SUITABLE LISTED BREAKERS MANUFACTURER CUTLER-HAMMER MURRY SIEMENS SQUARE D THOMAS & BETTS CIRCUIT BREAKER SINGLE DOUBLE TWIN QUAD GFCB BR MP-T QP HOM TB BR MP-T QP HOM TB BRD MH-T QT HOMT TBBD BRD MH-T QT HOMT TBBQ FILLER PLATE
SUPPLY WIRE SIZE CIRCUIT 75°C MIN BREAKER INSULATION RATING AWG AMP 14 15 20 12 10 30 8 50 6 60 TERMINAL TORQUE* MAX MOTOR LINE AND LOAD NEUTRAL NEUTRAL (CONTINUOUS MAIN AND DUTY) LUGS GROUND 120V. LB-IN LB-IN HP HP 35 20 1/2 1 35 20 1 2 35 20 1 1/2 3 40 25 2 5 45 35 ----GENERAL PURPOSE BRANCH CIRCUIT BREAKER RATING AMP 15 20 30 40 60 GENERAL PURPOSE BRANCH CIRCUIT MAXIMUM CURRENT CAPACITY AMP 12 16 24 32 44
60 AMP 120/240 VOLT OR 120/208 VOLT SINGLE PHASE, (THREE WIRE) AC
SUITABLE FOR SWIMMING POOL / SPA APPLICATIONS AND FOR DIRECT CONDUIT CONNECTION TO A WET-NICHE OR NO NICHE LUMINAIRE.
NOTES: 1. Any Intermatic T100M or ET100CM series Time Switch, PF1000M Series freeze protection or RC2000M Series air switch mechanism *TORQUE CIRCUIT BREAKER LUGS TO VALUES SPECIFIED ON may be installed in the bracket provided or in the event an existing CIRCUIT BREAKERS mechanism is replaced. If this control panel requires bonding, attach a LISTED bonding terminal of a suitable size using the mounting hole(s) provided on the bottom of the enclosure (156T11047A may be ordered). When a back-fed breaker is used in this control panel, order 22T904A to comply with NEC article 384-16 (g). Wiring devices may be installed in this control panel (order 21T156A (4) Standoffs for mounting). The following kits are available to connect under water luminaires to this enclosure: 1/2" non-metallic - order 156PA13713A 3/4" non-metallic - order 156PA13714A 1" non-metallic - order 156PA13715A 1/2" metallic - order 156PA14336A
TIME SWITCH RATINGS: 30 AMP. RESISTIVE, INDUCTIVE, TUNGSTEN OR 1000 VA PILOT DUTY 120/208/240 VOLT A. C. 2 HP (24 FLA)-120 VOLT A. C. , 5 HP (28 FLA)-240 VOLT A. C. CLOCK MOTOR: 208-277 VOLTS 60 HZ.
(To order clock motor replacement, specify part no. [. . . ] · IN CASE OF POWER FAILURE: Reset CLOCK-DIAL to proper time of day. See step 2 above.
INTERMATIC INCORPORATED
SPRING GROVE ILLINOIS 60081-9698 158TP12178 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERMATIC T21004R
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.