[. . . ] CA3140, CA3140A
Data Sheet September 1998 File Number 957. 4
4. 5MHz, BiMOS Operational Amplifier with MOSFET Input/Bipolar Output
The CA3140A and CA3140 are integrated circuit operational amplifiers that combine the advantages of high voltage PMOS transistors with high voltage bipolar transistors on a single monolithic chip. The CA3140A and CA3140 BiMOS operational amplifiers feature gate protected MOSFET (PMOS) transistors in the input circuit to provide very high input impedance, very low input current, and high speed performance. The CA3140A and CA3140 operate at supply voltage from 4V to 36V (either single or dual supply). These operational amplifiers are internally phase compensated to achieve stable operation in unity gain follower operation, and additionally, have access terminal for a supplementary external capacitor if additional frequency roll-off is desired. [. . . ] This technique is necessary because the voltage follower configuration approaches unity gain rather than the zero gain required to shape the sine wave at the two extremes.
Meter Driver and Buffer Amplifier
Figure 11 shows the CA3140 connected as a meter driver and buffer amplifier. Low driving impedance is required of the CA3080A current source to assure smooth operation of the Frequency Adjustment Control. This low-driving impedance requirement is easily met by using a CA3140 connected as a voltage follower. Moreover, a meter may be
9
CA3140, CA3140A
CENTERING -15V 10k 62k 5 2 11k 11k 10k 0. 1 µF EXTERNAL OUTPUT 3
+15V
7. 5k 360 3 360 2 2M SYMMETRY -15V +15V 100k FROM BUFFER METER DRIVER (OPTIONAL) 39k -15V +
+15V 7 15k 6 7-60 pF HIGH FREQ. SHAPE 4 5 -15V 51 pF 3 2
+15V 0. 1 µF 6
7 + CA3140
HIGH FREQUENCY LEVEL 910k 7-60pF
10k EXTERNAL OUTPUT 6 2. 7k -15V TO OUTPUT AMPLIFIER
CA3080A
-
-
7
4 -15V 2k
CA3080 + 4 13k
120
10k +15V
FREQUENCY ADJUSTMENT
5. 1k
TO SINE WAVE SHAPER
THIS NETWORK IS USED WHEN THE OPTIONAL BUFFER CIRCUIT IS NOT USED
OUTPUT AMPLIFIER
1N914
FIGURE 10A. CIRCUIT
FREQUENCY ADJUSTMENT
Top Trace: Output at junction of 2. 7 and 51 resistors; 5V/Div. , 500ms/Div. Center Trace: External output of triangular function generator; 2V/Div. , 500ms/Div. Bottom Trace: Output of "Log" generator; 10V/Div. , 500ms/Div. FIGURE FUNCTION GENERATOR SWEEPING
METER DRIVER AND BUFFER AMPLIFIER FUNCTION GENERATOR
+15V M POWER SUPPLY ±15V -15V
SINE WAVE SHAPER
WIDEBAND LINE DRIVER
51 GATE DC LEVEL SWEEP ADJUST OFF INT. EXTERNAL INPUT
FINE RATE
SWEEP GENERATOR
1V/Div. , 1s/Div. Three tone test signals, highest frequency 0. 5MHz. Note the slight asymmetry at the three second/cycle signal. This asymmetry is due to slightly different positive and negative integration from the CA3080A and from the PC board and component leakages at the 100pA level. FUNCTION GENERATOR WITH FIXED FREQUENCIES
SWEEP LENGTH V-
FIGURE 10D. FUNCTION GENERATOR
10
CA3140, CA3140A
FREQUENCY CALIBRATION MAXIMUM 620k 7 51k 3 + CA3140 3M 2 6 4. 7k 4 2k +15V 0. 1µF 12k FREQUENCY 2. 4k CALIBRATION MINIMUM 2. 5 k 510 8 2k 6 7 METER POSITION ADJUSTMENT 12 3. 6k 13
500k FREQUENCY ADJUSTMENT 10k SWEEP IN
-
TO CA3080A OF FUNCTION CA3080A GENERATOR (FIGURE 10) 4 5 METER SENSITIVITY ADJUSTMENT 620 1k 200µA M METER 11 9 510 10 14
+15V
-15V 0. 1µF
3 5. 1k 2
+
7 6
5. 6k 7. 5k SUBSTRATE OF CA3019 TO WIDEBAND OUTPUT AMPLIFIER 10k EXTERNAL OUTPUT
CA3140
-
4
0. 1µF +15V 100 k -15V 1M D1 9. 1k 6 D3 R1 10k
7 -15V R3 10k D4 5 D6 9 1 8 D2 2
430 R2 1k
3/ OF CA3086 5
-15V
3 4 D CA3019 5 DIODE ARRAY
FIGURE 11. METER DRIVER AND BUFFER AMPLIFIER
FIGURE 12. SINE WAVE SHAPER
750k "LOG" SAWTOOTH 18M 1N914 1M 22M SAWTOOTH SYMMETRY 100k 100k FINE RATE 8. 2k
1N914 0. 47µF 0. 047µF 4700pF 470pF
+15V SAWTOOTH AND RAMP LOW LEVEL SET (-14. 5V) 50k 75k
COARSE RATE
2 3
-
7
+15V 0. 1 µF 6 0. 1 µF
SAWTOOTH "LOG"+15V TRIANGLE 30k 50k LOG RATE ADJUST 10k -15V 36k 3 100k TO OUTPUT 2 AMPLIFIER
51k +15V
CA3140 + 4
-
7 6 10k GATE PULSE OUTPUT
CA3140 + 4
-15V
43k
-15V
10k
EXTERNAL OUTPUT
TO FUNCTION GENERATOR "SWEEP IN" SWEEP WIDTH +15V
3 2 LOGVIO
+
CA3140
7 6 4 51k 6. 8k 91k
1 25k 3. 9 -15V 5
10k TRIANGLE
5 4 3 2
1 TRANSISTORS FROM CA3086 ARRAY
SAWTOOTH "LOG"
100 390
FIGURE 13. SWEEPING GENERATOR
11
CA3140, CA3140A
This circuit can be adjusted most easily with a distortion analyzer, but a good first approximation can be made by comparing the output signal with that of a sine wave generator. The initial slope is adjusted with the potentiometer R1, followed by an adjustment of R2. The final slope is established by adjusting R3, thereby adding additional segments that are contributed by these diodes. Because there is some interaction among these controls, repetition of the adjustment procedure may be necessary. Sweeping Generator Figure 13 shows a sweeping generator. [. . . ] Bottom Trace: Input Signal; 5V/Div. , 2µs/Div. LARGE SIGNAL RESPONSE AND SETTLING TIME
SAMPLING RESPONSE Top Trace: Output; 100mV/Div. , 500ns/Div. Bottom Trace: Input; 20V/Div. , 500ns/Div. SAMPLE AND HOLD SYSTEM DYNAMIC CHARACTERISTICS WAVEFORMS
16
CA3140, CA3140A
R2 5k +15V 0. 1µF R1 2 10k 3 0. 1µF 10k INPUT 3 2 10k R3 100k OFFSET ADJUST PEAK ADJUST 10k + CA3140 6 4 1N914 6 100pF 2k 7 SIMULATED LOAD +15V
CA3140 + 8 1 5
7
4 0. 1µF -15V 2k 0. 05µF
BW (-3dB) = 4. 5MHz SR = 9V/µs
R2 R3 GAIN = ------ = X = ---------------------------R1 R1 R2 + R3 X+X R 3 = ---------------- R 1 1X R2 5k FOR X = 0. 5 -------------- = -----10k R1 0. 75 R 3 = 10k ---------- = 15k 0. 5
2
FIGURE 28A. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE INTERSIL CA3140AM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.