User manual ISEKI KC 350

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ISEKI KC 350. We hope that this ISEKI KC 350 user guide will be useful to you.

Lastmanuals help download the user guide ISEKI KC 350.


Mode d'emploi ISEKI KC 350
Download
Manual abstract: user guide ISEKI KC 350

Detailed instructions for use are in the User's Guide.

[. . . ] Pass them on to possible new owners of the appliance. also be equipped with vents to allow gas to escape in the event of a leak. As a result LPG cylinders, whether partially or completely full, must not be installed or stored in rooms or storage areas that are below ground level (cellars, etc. ). It is advisable to keep only the cylinder being used in the room, positioned so that it is not subject to heat produced by external sources (ovens, fireplaces, stoves, etc. [. . . ] The internal burner has a nozzle, the external burner has two (of the same size). Replace the nozzle with models suited to the new type of gas (see table 1). replace all the components by repeating the steps in reverse order. • Setting the burners to minimum: 1. Remove the knob and adjust the adjustment screw, which is positioned in or next to the tap pin, until the flame is small but steady. GB 3. Having adjusted the flame to the required low setting, while the burner is alight, quickly change the position of the knob from minimum to maximum and vice versa several times, checking that the flame does not go out. Some appliances have a safety device (thermocouple) fitted. If the device fails to work when the burners are set to the low flame setting, increase this low flame setting using the adjusting screw. Once the adjustment has been made, replace the seals on the by-passes using sealing wax or a similar substance.  If the appliance is connected to liquid gas, the regulation screw must be fastened as tightly as possible.  Once this procedure is finished, replace the old rating sticker with one indicating the new type of gas used. Stickers are available from any of our Service Centres. operates the The knob marked by the symbol external burner; operates the The knob marked by the symbol internal burner. To turn on one of the rings, press the relative knob in all the way and turn it anti-clockwise to the high setting . The burner is fitted with an electronic igniter that automatically starts when the knob is pressed in. Since the burner is equipped with a safety device, after lighting the burner keep the knob pressed in for about 2-3 seconds to allow the device which keeps the flame lit automatically to heat up. The selected burner can be regulated using the corresponding knob, as follows: • Off Maximum Minimum To switch off the burner, turn the knob in a clockwise direction until it stops (when reaches the “•” position). Ceramic Glass Module* This cooktop is fitted with dual-ring radiant heating elements located beneath the glass. It is possible to turn on only the circular part of the elemement (identified by the letter "A") or the cooking surface can be enlarged by turning on both "A" and "B". To turn only the circular "A" element, simply turn the knob in the clockwise direction to any one of the 12 available settings. To add the "B" section, turn the knob to setting. Then setting 12 and then click it into the proceed by turning the knob in the counter-clockwise direction to one of the 12 settings. The figure shows the heating zones, which become red when the element is turned on. [. . . ] • It is usually enough to wash the hob with a damp sponge and dry it with absorbent kitchen roll. • The removable parts of the burners should be washed frequently with warm water and soap and any burnt-on substances removed. • For hobs which ligth automatically, the terminal part of the electronic instant lighting devices should be cleaned frequently and the gas outlet holes should be checked for blockages. • Stainless steel can be marked by hard water that has been left on the surface for a long time, or by aggressive detergents containing phosphorus. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ISEKI KC 350

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ISEKI KC 350 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag