User manual ITS TELECOM PANDOOR INSTALLATION RELEASE 1.5 V1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual ITS TELECOM PANDOOR. We hope that this ITS TELECOM PANDOOR user guide will be useful to you.

Lastmanuals help download the user guide ITS TELECOM PANDOOR.


Mode d'emploi ITS TELECOM PANDOOR
Download
Manual abstract: user guide ITS TELECOM PANDOORINSTALLATION RELEASE 1.5 V1

Detailed instructions for use are in the User's Guide.

[. . . ] 4 Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Installing the PanDoor Wall Bracket. . . . . . . . . . . . . . . . . . . . . 7 Installing the PanDoor Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Installing the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 LED Indications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The PanDoor can be connected to an external bypass switch for opening the door lock. This switch can be installed inside the residence and should be connected to the SW and /SW terminals on the PanDoor wire connector. Figure 5 illustrates the terminal locations on the wire connector of the outdoor panel. All wiring to the unit should be attached to the wire connector. The wire connector is a screw connector type. In order to attach a wire, you must insert the stripped end of the wire into the appropriate terminal and tighten the terminal screw. This will crimp the wire connection. 8 PanDoor Installation and Programming Manual Installation +12V -12V CMN N. O. DLR -DLR /DLR /SW 12VDC power input from controller Normally open/closed outputs (external device) Door lock relay terminals Switch terminals SW CCTV+ Camera power output CCTVTIP RING Figure 5. Outdoor Panel Wire Connector PanDoor Installation and Programming Manual 9 Installation To install the PanDoor Panel: 1. Remove the PanDoor panel cover and locate the wire connector. Connect the 12V wires from the controller to the +12V and -12V terminals. Connect the audio wires from the controller to the TIP and RING terminals. Connect the door lock relay wires to the DLR and -DLR terminals. Alternatively, if the door lock relay is a poweredlocked-state type lock, connect the door lock relay wires to the /DLR and -DLR terminals. If an external bypass switch is installed, connect its wires to the SW and /SW terminals. Place the PanDoor panel onto its mounting bracket. If required to install another outdoor unit, repeat steps 1 to 6. 2. 3 Installing the Controller The controller is installed indoors. It receives power from a 12VAC transformer supplied with the unit. The controller powers the outdoor units through 12VDC wires connected to its KEYPAD POWER terminals. Figure 6 illustrates the terminal locations on the wire connector of the controller. Note Verify correct connection of the connectors to the controller. The polarity sign (+ or -) appears on the connectors. 10 PanDoor Installation and Programming Manual Installation TIP TELCO RING TIP PSTN phone line HOUSE RING TIP House phone line KEYPAD 1 RING TIP Keypad 1 phone line KEYPAD 2 RING V+ Keypad 2 phone line KEYPAD 1 POWER VV+ 12VDC output to keypad 1 panel KEYPAD 2 POWER VV+ 12VDC output to keypad 2 panel BATTERY VV+ 12V battery input (optional) CHARGER V- 13. 8V charger input (optional) Figure 6. Controller Unit Wire Connector PanDoor Installation and Programming Manual 11 Installation To install the controller: 1. [. . . ] After switching from PSTN to panel and opening the door, I cannot return to the PSTN call. Music during the waiting period is a normal operational situation, with timeout of 20 seconds. This could mean that the person inside the house did not answer the telephone, or that he chose not to accept call waiting. Check that internal access code is defined correctly. Make sure you are connected to the correct panel, and using the correct code. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE ITS TELECOM PANDOOR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual ITS TELECOM PANDOOR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag