Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JBSYSTEMS LIGHT SUPER SOLAR RGBW. We hope that this JBSYSTEMS LIGHT SUPER SOLAR RGBW user guide will be useful to you.
Lastmanuals help download the user guide JBSYSTEMS LIGHT SUPER SOLAR RGBW.
Manual abstract: user guide JBSYSTEMS LIGHT SUPER SOLAR RGBWV1.0
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 8--ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 9--FAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 10--EDIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. 3. 11--SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. [. . . ] 4. 2--CHANNEL ASSIGNMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13. 4. 3--BASIC INSTRUCTIONS FOR DMX512 OPERATION (STAGE 1). . . . . 16.
PART 5 APPENDIX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.
5. 1--TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17. 5. 2--MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.
1
1. 1
PRODUCT (GENERAL)
PRODUCT INTRODUCTION
This product is designed for indoor use. Suitable applications include wash or effect lighting for architectural, stage or nightclub applications. This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. All programs can be touch-button displayed or scheduled to START and END at scheduled times. It is possible to further adjust the angle of the LED MODULE using the two adjustment knobs located on the side of the fixture.
2. 2
POWER CONNECTIONS
@ 220V: 40 units may be connected in series @120V: 20 units may be connected in series Note: As this fixture's DMX signal cable connection had been changed to Parallel connection, so if over 30 units to be connected, then a DMX signal amplifier is needed.
2 INSTALLATION
5
2009. 12. 9
2. 3
SETTING UP WITH A DMX512 CONTROLLER
2. 3-1 DMX512 ADDRESSING WITHOUT ID ADDRESSING (STAGE 1 MODE)
Connect the DMX512 controller to the units in series. Each unit has 9 DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) The ID address has not been set so therefore when using the controller Ch9 must be inactive ( CH9=0 ). Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used.
Example:
The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 10 and so on. . . (Note that when used in this way, the CH9 ID function must be inactive (CH9=0))
2. 3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAGE 1 MODE)
Connect the DMX512 controller to the units in series Each unit has 9DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used. Each DMX address may carry up to 66 separate ID addresses. ID should be set in the menu on each unit in ascending values (i. e. 1, 2, 3. . . ) ID addresses are accessible from Ch9 on the DMX512 controller.
2 INSTALLATION
6
2009. 12. 9
Example:
The figure above shows a simple DMX layout which has used three units at each DMX address. [. . . ] The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH9 to 0, or to control each unit independently by first selecting the DMX address and then by using Ch9 to locate the target ID address.
2 INSTALLATION
7
2009. 12. 9
3
3. 1
DISPLAY PANEL OPERATION
BASIC
MENU
scroll through the main menu or exit from the current menu or function
ENTER Enter the currently selected menu or confirm the current function value UP DOWN scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function
2 INSTALLATION
8
2009. 12. 9
3. 2
MENU
3 DISPLAY PANEL OPERATION
9
2009. 12. 9
3. 3
STATIC
STATIC Select RED / GREN / BLUE / STRB to set the value
3. 4
AUTO
AUTO Select the target AUTO program and press ENTER Programs AUTO 1 to AUTO 10 are fully pre-programmed and will not be altered Programs Custom 1 to Custom 10 are fully pre-programmed and can be edited
3. 5
ADDRESS
ADDRESS Enter ADDRESS and set the DMX address 001~512
3. 6
RUN
RUN Enter RUN to choose SLAVE or DMX working mode
3 DISPLAY PANEL OPERATION
10
2009. 12. 9
3. 7
PERSON
PERSON Enter PERSON and select STAGE1 / ARC1 / ARC1+D DMX mode
3. 8
ID
ID Enter ID and set the ID address 001~066
3. 9 FAN
FAN Enter Fan and select the working mode of fan: High Normal , Auto or Low . ,
3. 10
EDIT
EDIT Enter EDIT to edit the custom programs custom 1 to custom 10 Each program has 30 steps to edit Each step allows a creation of a scene using RED, GREEN, BLUE, STRUBE, TIME, FADE
3 DISPLAY PANEL OPERATION
11
2009. 12. 9
3. 11
SETTINGS
ID Choose ON / OFF to open or close ID
Reset to Factory?This function will reset all setting to the original factory setting Up load custom?to upload the custom programs from the current MASTER unit to the SLAVE units COLOR is f ora ctivate/unactivatet hec olorc alibrationf unctions. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT SUPER SOLAR RGBW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT SUPER SOLAR RGBW will begin.