User manual JBSYSTEMS LIGHT SUPER SOLAR WHITE V1.0
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JBSYSTEMS LIGHT SUPER SOLAR WHITE. We hope that this JBSYSTEMS LIGHT SUPER SOLAR WHITE user guide will be useful to you.
Lastmanuals help download the user guide JBSYSTEMS LIGHT SUPER SOLAR WHITE.
Manual abstract: user guide JBSYSTEMS LIGHT SUPER SOLAR WHITEV1.0
Detailed instructions for use are in the User's Guide.
[. . . ] 3. 8--ID. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 9--FAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3. 10--EDIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11. 3. 11--SETTINGS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12. [. . . ] 4. 3--BASIC INSTRUCTIONS FOR DMX512 OPERATION (STAGE 1). . . . . 16.
PART 5 APPENDIX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17.
5. 1--TROUBLE SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17. 5. 2--MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18.
1
1. 1
PRODUCT (GENERAL)
PRODUCT INTRODUCTION
This product is designed for indoor use. Suitable applications include wash or effect lighting for architectural, stage or nightclub applications. This product can also be installed for use in signage and advertising using the dynamic functions available with DMX512 control. Direct input of DMX512 signal allows the units to be controlled from any DMX512 controller. This product can be operated as a single unit or in multiple units for large applications. The specially developed controller that allows the product to be controlled independent of the DMX512 controller enables the user to create and edit a wide range of custom programs. All programs can be touch-button displayed or scheduled to START and END at scheduled times. When programs have been created or edited in the controller, it is also possible to trigger these programs using the DMX IN function when connected to a DMX512 controller.
1. 2
PRODUCT FEATURES
LED FIXTURE
* RGB Dimmer 0-100% * Strobe * Automatic programs * LCD display * Display control 'lock-out' * Direct DMX512 input * Independant ID address * Stand-alone/ Slave
1 PRODUCT(GENERAL)
1
2009. 12. 9
1. 3
TECHNICAL SPECIFICATIONS
LED MODULE
LED MODULE: Voltage Rated Power LED/Unit Output/LED 100~240V. . . 50/60Hz 30W 18pcs (6 x RED / 6 x GREEN / 6 x BLUE) 1W ~40
Environment Temperature -20 Cooling Dimensions Weight
Forced air convection 240 x 210 x160mm 2. 5Kg
1 PRODUCT(GENERAL)
2
2009. 12. 9
1. 4
PHOTOMETRIC DATA
PHOTOMETRIC DATA
1 PRODUCT(GENERAL)
3
2009. 12. 9
1. 5
SAFETY WARNING
IMPORTANT
ALWAYS READ THE USER MANUAL BEFORE OPERATION. Each unit has 9 DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) The ID address has not been set so therefore when using the controller Ch9 must be inactive ( CH9=0 ). Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used.
Example:
The figure above shows a simple DMX512 layout with the starting address of the first unit set at 1, with the second set at 10 and so on. . . (Note that when used in this way, the CH9 ID function must be inactive (CH9=0))
2. 3-2 DMX512 ADDRESSING WITH ID ADDRESS (STAGE 1 MODE)
Connect the DMX512 controller to the units in series Each unit has 9DMX channels so the DMX Addresses should increase by increments of 9 (e. g. 1, 10, 19, 28. . . ) Each DMX Address may be used as many times as required. Any DMX address in the range from 001 to 512 may be used. Each DMX address may carry up to 66 separate ID addresses. ID should be set in the menu on each unit in ascending values (i. e. 1, 2, 3. . . ) ID addresses are accessible from Ch9 on the DMX512 controller.
2 INSTALLATION
6
2009. 12. 9
Example:
The figure above shows a simple DMX layout which has used three units at each DMX address. The three units have different ID addresses which allows the user to collectively control the whole group of units at that DMX address by setting CH9 to 0, or to control each unit independently by first selecting the DMX address and then by using Ch9 to locate the target ID address.
2 INSTALLATION
7
2009. 12. 9
3
3. 1
DISPLAY PANEL OPERATION
BASIC
MENU
scroll through the main menu or exit from the current menu or function
ENTER Enter the currently selected menu or confirm the current function value UP DOWN scroll 'UP' through the menu list or increase the value of the current function scroll 'DOWN' through the menu list or decrease the value of the current function
2 INSTALLATION
8
2009. 12. 9
3. 2
MENU
3 DISPLAY PANEL OPERATION
9
2009. 12. 9
3. 3
STATIC
STATIC Select RED / GREN / BLUE / STRB to set the value
3. 4
AUTO
AUTO Select the target AUTO program and press ENTER Programs AUTO 1 to AUTO 10 are fully pre-programmed and will not be altered Programs Custom 1 to Custom 10 are fully pre-programmed and can be edited
3. 5
ADDRESS
ADDRESS Enter ADDRESS and set the DMX address 001~512
3. 6
RUN
RUN Enter RUN to choose SLAVE or DMX working mode
3 DISPLAY PANEL OPERATION
10
2009. 12. 9
3. 7
PERSON
PERSON Enter PERSON and select STAGE1 / ARC1 / ARC1+D DMX mode
3. 8
ID
ID Enter ID and set the ID address 001~066
3. 9 FAN
FAN Enter Fan and select the working mode of fan: High Normal , Auto or Low . [. . . ] to upload the custom programs from the current MASTER unit to the SLAVE units COLOR is f ora ctivate/unactivatet hec olorc alibrationf unctions. When [UC] is selected, the RGB output are adjusted to a standard preset universal color which balances fixtures from different generations. . The factory default setting is [UC] on.
3. 12
PASSWORD
PASSWORD Enter the PASSWORD mode to select whether the access password is on or off. When the fixture is set as PASS ON , after 30 seconds or turn on the fixture next time, the fixture will need an access password to enter the display menu control. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JBSYSTEMS LIGHT SUPER SOLAR WHITE
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JBSYSTEMS LIGHT SUPER SOLAR WHITE will begin.