Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JETWAY 603TCR1C. We hope that this JETWAY 603TCR1C user guide will be useful to you.
Lastmanuals help download the user guide JETWAY 603TCR1C.
Detailed instructions for use are in the User's Guide.
[. . . ] 603TCF/603TCFL
Socket 370
G03-603TCR1C
2002 8
: *
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
603TCF/603TCFL
1-1 1-2 1-3 1-4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Capability Video BIOS Shadow :Move Enter:Select F5:Previous Values [Disabled] Enabled Enabled Disabled Disabled Enabled Floppy HDD-0 CDROM Enabled Disabled Enabled On Normal Disabled 6 250 Setup Non-OS2 Disabled Enabled +/-/PU/PD:Value F10:Save F6:Optimized Defaults Item Help Menu Level > Allows you to choose the VIRUS warning feature for IDE Hard disk boot sector protection. If this function is enabled and someone attempt to write data into this area, BIOS will show a warning message on screen and alarm beep enabled copies Video BIOS to shadow RAM improves performance
ESC:Exit F1:General Help F7:Standard Defaults
Virus Warning Allows you to choose the VIRUS Warning feature for IDE Hard Disk boot sector protection. If this function is enabled and someone attempt to write data into this area, BIOS will show a warning message on screen and alarm beep. Disabled (default) No warning message to appear when anything attempts to access the boot sector or hard disk partition table. Enabled Activates automatically when the system boots up causing a warning message to appear when anything attempts to access the boot sector of hard disk partition table.
3-6 Advanced Chipset Features
The Advanced Chipset Features Setup option is used to change the values of the chipset registers. These registers control most of the system options in the computer.
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Advanced Chipset Features
24
Advanced DRAM Control Advanced AGP Control Memory Hole System BIOS Cacheable Video RAM Cacheable Memory Parity/ECC Check
[Press Enter] Press Enter Disabled Disabled Disabled Disabled
Item Help Menu Level >
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
Note: Change these settings only if you are familiar with the chipset. Advanced DRAM Control Please refer to section 3-6-1
3-6-1 Advanced DRAM Control
The "Advanced DRAM Control" includes settings for the chipset dependents features. These features are related to system performance. Make sure you fully understand the items contained in this menu before you try to change anything. You may change the parameter settings to improve system performance. However, it may cause your system to be unstable if the setting is not correct for your system configuration.
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Advanced DRAM Control Auto Configuration Precharge Command [Optimized] 3T Item Help
25
Active to CMD Command Write Recovery Time SDRAM Cycle Length Bank Interleave DRAM Drive Strength Delay DRAM Read Latch Memory Data Drive Memory CMD Drive DDSKEW/REFCLK Delay In-Order Queue P2C/C2P Concurrency Fast R-W Turn Around I/O Recovery Time CPU to PCI Write Buffer PCI Dynamic Bursting PCI Master 0 WS Write PCI Delay Transaction PCI#2 Access #1 Retry :Move Enter:Select F5:Previous Values
6T 2T By SPD By SPD Auto 1. 0 ns Normal Strong No Delay 1-Level Disabled Disabled Disabled Enabled Disabled Disabled Disabled [Disabled] +/-/PU/PD:Value F10:Save F6:Optimized Defaults
Menu Level >>
ESC:Exit F1:General Help F7:Standard Defaults
Precharge Command If an insufficient number of cycles is allowed for the RAS to accumulate its charge before DRAM refresh, the refresh may be incomplete and the DRAM may fail to retain date. Fast gives faster performance; and Slow gives more stable performance. This field applies only when synchronous DRAM is installed in the system. Active Command This field let's you insert a timing delay between the CAS and RAS strobe signals, used when DRAM is written to, read from, or refreshed. Fast gives faster performance; and Slow gives more stable performance. This field applies only when synchronous DRAM is installed in the system. Active to CMD Command Select the number of SCLKs for an access cycle. SDRAM Cycle Length When synchronous DRAM is installed, the number of clock cycles of CAS latency depends on the DRAM timing. PCI Delay Transaction The chipset has an embedded 32-bit posted write buffer to support delay transactions cycles. Select Enabled to support compliance with PCI specification version 2. 1. The settings are: Enabled and Disabled.
3-7 Integrated Peripherals
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Integrated Peripherals > OnChip IDE Function > OnChip DEVICE Function [Press Enter] Press Enter Item Help
26
> OnChip SUPERIO Function Init Display First
Press Enter PCI Slot
Menu Level >
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
OnChip IDE Function
Please refer to section 3-7-1 OnChip DEVICE Function Please refer to section 3-7-2 OnChip SUPERIO Function Please refer to section 3-7-3 Init Display First This item allows you to decide to activate whether PCI Slot or AGP VGA first. The settings are: PCI Slot, AGP Slot.
3-7-1 OnChip IDE Function
CMOS Setup Utility Copyright(C) 1984-2002 Award Software OnChip IDE Function OnChip IDE Channel0 OnChip IDE Channel1 [Enabled] Enabled Item Help
27
IDE 32bit Transfer Mode Primary Master PIO Primary Slave PIO Secondary Master PIO Secondary Slave PIO Primary Master UDMA Primary Slave UDMA Secondary Master UDMA Secondary Slave UDMA IDE HDD Block Mode IDE Prefetch Mode
Disabled Auto Auto Auto Auto Auto Auto Auto Auto Enabled Disabled
Menu Level >>
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
3-7-2 OnChip DEVICE Function
CMOS Setup Utility Copyright(C) 1984-2002 Award Software OnChip DEVICE Function OnChip AUDIO Function RealTak LAN Function OnChip USB USB Keyboard Support [Press Enter] Enabled Enabled Disabled
(For 603TCFL)
Menu Level >>
:Move
Enter:Select
+/-/PU/PD:Value
F10:Save
ESC:Exit
F1:General Help
F5:Previous Values
F6:Optimized Defaults
F7:Standard Defaults
3-7-3 OnChip SUPERIO Function
CMOS Setup Utility Copyright(C) 1984-2002 Award Software OnChip SUPERIO Function
28
Onboard FDD Function Onboard Serial Port 1 Onboard Serial Port 2 UART 2 Mode IR Duplex Mode TX, RX Inverting enable Onboard Parallel Port Onboard Parallel Mode ECP Mode Use DMA Parallel Port EPP Type :Move Enter:Select
[Enable] Auto Auto Normal Half Ho, Yes 378/IRQ7 SPP 3 EPP1. 9 +/-/PU/PD:Value F10:Save
Item Help Menu Level >>
ESC:Exit
F1:General Help
F5:Previous Values
F6:Optimized Defaults
F7:Standard Defaults
3-8 Power Management Setup
The Power Management Setup allows you to configure your system to most effectively save energy saving while operating in a manner consistent with your own style of computer use.
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Power Management Setup ACPI Function > Power Management PM Control by APM Video off Option Video Off Method MODEM Use IRQ Soft-Off by PWRBTN > Wake Up Events [Enabled] Press Enter Yes Suspend -> Off V/H SYNC+Blank 3 Instant-Off Press Enter Item Help Menu Level >
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
Wake-Up Events Please refer to section 3-8-2
3-8-1 Power Management
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Power Management
29
Power Management HDD Power Down Doze Mode Suspend Mode
[User Define] Disabled Disabled Disabled
Item Help Menu Level >>
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
3-8-2 Wake Up Events
CMOS Setup Utility Copyright(C) 1984-2002 Award Software Wake Up Events VGA LPT & COM HDD & FDD PCI Master Modem Ring Resume RTC Alarm Resume x Date (of Month) x Resume Time (hh:mm:ss) > IRQs Activity Monitoring [OFF] LPT/COM ON OFF Disabled Disabled 0 0:7:0 Press Enter Item Help Menu Level >>
:Move Enter:Select F5:Previous Values
+/-/PU/PD:Value F10:Save F6:Optimized Defaults
ESC:Exit F1:General Help F7:Standard Defaults
IRQs Activity Monitoring Please refer to section 3-8-2. 1
3-8-2. 1 IRQs Activity Monitoring
CMOS Setup Utility Copyright(C) 1984-2002 Award Software IRQs Activity Monitoring
30
Primary INTR IRQ3 (COM 2) IRQ4 (COM 1) IRQ5 (LPT 2) IRQ6 (Floppy Disk) IRQ7 (LPT 1) IRQ8 (RTC Alarm) IRQ9 (IRQ2 Redir) IRQ10 (Reserved) IRQ11 (Reserved) IRQ12 (PS/2 Mouse) IRQ13 (Coprocessor) IRQ14 (Hard Disk) IRQ15 (Reserved)
[ON] Enabled Enabled Enabled Enabled Enabled Disabled Disabled Disabled Disabled Enabled Enabled Enabled Disabled
Item Help Menu Level >>>
Move Enter:Select Item +/-/PU/PD:Value F10:Save ESC:Exit F5:Previous Values
F1:General Help
F6:Optimized Defaults F7:Standard Defaults
3-9 PnP/PCI Configuration Setup
This section describes configuring the PCI bus system. [. . . ] This would prevent unauthorized use of your computer. You determine when the password is required within the BIOS Features Setup Menu and its Security option. If the Security option is set to "System", the password will be required both at boot and at entry to Setup. If set to "Setup", prompting only occurs when trying to enter Setup.
34
MAGIC INSTALL MAGIC INSTALL
WINDOWS 95/98/98SE/ME/NT4. 0/2000/XP MAGIC INSTALL
MAGIC INSTALL "" "" "" ":\SETUP. EXE" ( )
MAGIC INSTALL 11 1. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JETWAY 603TCR1C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JETWAY 603TCR1C will begin.