[. . . ] 2004
JRC SAW FILTER
NSVS1120
Application
570MHz WLAN IF
Electrical Specification: (Table 1) The device characteristics are measured in the circuit shown in Fig. 1. Electrical Specifications Item Input and Output Impedance Nominal Center Frequency (f0) Insertion Loss 561. 5~578. 5MHz Response Variation 561. 5~578. 5MHz Input and Output VSWR 561. 5~578. 5MHz Group Delay Ripple 561. 5~578. 5MHz Out of Band Rejection 370~548MHz (Relative to 553MHz Through Level) 555MHz 585MHz 587MHz 592~770MHz
Spec. [. . . ] Use this component within operating temperature range. It might not be satisfied with electrical specification without operating temperature range. When it is used less than -20ºC or more than +60ºC, it might be a cause of degradation or destruction of the component. Even if it endures during a short time, it causes degradation of qualification. When soldering iron is used, solder with the temperature at the tip of soldering iron: 350ºC max. , the time of soldering: 10 seconds max. , the power of soldering iron: 30W max. . Notice that the allowed time of soldering with soldering iron is accumulated time, when soldering is repeated. As rapid temperature change for cleaning after reflow soldering might be a cause of destruction clean this component after confirming that temperature of this component goes down to room temperature. Confirm that there are not any influence for qualification to this component in mounting on PCB when this component is cleaned. As it might be a cause of degradation of destruction to apply static electricity to this component, do not apply static electricity or excessive voltage while assembling and measuring. And do not transport this component with bare hand. As it might be a cause of degradation or destruction to apply D. C. voltage between each terminal, apply D. C. [. . . ] 2004
IN 50 O
*27nH
11
10
,
X
,
W , U
,
V
OUT 50 O
39pF
12
SAW
, P , Q ,
, T R
*27nH
, S 33pF
0
S21
FREQUENCY CHARACTERISTICS
*murata LQW18A series
0
Insertion Loss [dB]
10
2
(1)
13. 30±0. 20
20
(a) (b)
(C)
(1. 26±0. 13)
(2)
4
30
6
40
50
CH1 : center 570 span 200 CH2 : center 570 span 200
J4Y1 VS971
6. 5±0. 20
8
10
S11
(3)
S22
(R0. 3) [4×]
Marking (1) Manufacture's Mark (2) Lot Number (a) Year
2. 0 max.
(b) Month *Oct. --- X Nov. --- Y Dec. --- Z (c) Date
(0. 76) VSWR
S11
11 9 7 5 3 1 470
(2. 54)
(2. 54)S22
11 9 7 5 3 670 1 470
1 --- 0 -9 10 -19 --- 1 20 -31 --- 2 (3) Part Number Mark
VSWR
(2. 54±0. 15)
(1. 4)
[12×]
Pin No. Connection 1
670
GND(PKG) GND(PKG) GND(PKG) GND(PKG) OUT/IN GND(signal) GND(PKG) GND(PKG) GND(PKG) GND(PKG) IN/OUT GND(signal)
(0. 8)
Frequency [MHz]
Frequency [MHz]
2 3 4 5 6
GroupDelay [nsec]
250 200 150 100 50 0 470 570
(R0. 3)
[12×]
12
1
2
3
4
5
(2. 54±0. 15)
[12 ×]
7 8
11 10
9
8
7
6
9 10 11 12
670
Fig. 2 Package dimensions(in mm)
Insertion Loss [dB]
Fig. 1 Measuring circuit [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JRC NSVS1120
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.