User manual JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS E SERIES END-OF-LIFE MODULE GUIDE 6-10-2010

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS. We hope that this JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS user guide will be useful to you.

Lastmanuals help download the user guide JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS.


Mode d'emploi JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS
Download
Manual abstract: user guide JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERSE SERIES END-OF-LIFE MODULE GUIDE 6-10-2010

Detailed instructions for use are in the User's Guide.

[. . . ] E SeriesTM Broadband Services Routers E SeriesTM End-of-Life Module Guide Published: 2010-10-06 Copyright © 2010, Juniper Networks, Inc. E Series End-of-Life Module Guide This guide provides an overview and description of E Series modules that are end-of-life (EOL) and can no longer be ordered for the following routers: · · · · · ERX7xx models ERX14xx models ERX310 router E120 router E320 router Depending on the EOL schedule of a module, new software releases might not support the module. Table 1 on page 3 lists EOL modules alphabetically. It lists EOL modules for ERX routers first and then for E120 and E320 routers. NOTE: Any future JunosE release number provided in the Actual or Predicted Last JunosE Support field of Table 1 on page 3 is based on the current JunosE release schedule. If the release schedule changes in the future, Juniper Networks will update the associated Product Support Notification (PSN) Technical Bulletin for any affected EOL modules. For more information about E Series routers and modules, refer to the following guides: · · · · ERX module installation and maintenance--ERX Hardware Guide E120 and E320 module installation and maintenance--E120 and E320 Hardware Guide Managing E Series routers--JunosE System Basics Configuration Guide Configuring E Series modules--JunosE Link Layer Configuration Guide To obtain the most current list of EOL modules, see the End-of-Life Products page on the Juniper Networks Web site at http://www. juniper. net/support/eol. 2 Copyright © 2010, Juniper Networks, Inc. Table 1: End-of-Life Modules Actual or Predicted Last JunosE Support Combination Name ERX ROUTER MODULES CE1 CE1 Line Module Label I/O Module Label First JunosE Support Page CE1 CE1 FULL I/O 1. 1. 0 7. 3. x 8 Channelized OC3/STM1 cOC3/STM1 multimode cOCx/STMx F0 cOC3 STM1 F0 I/O MULTIMODE cOC3/STM1 single-mode intermediate reach cOCx/STMx F0 cOC3 STM1 F0 I/O SINGLE MODE cOC3/STM1 single-mode long reach cOCx/STMx F0 cOC3 STM1 F0 I/O LONG HAUL 2. 2. 0 15. 0. x 13 2. 2. 0 15. 0. x 11 2. 2. 0 15. 0. x 9 Channelized OC12/STM4 cOC12/STM4 multimode without APS/MSP redundancy cOCx/STMx F0 cOC12 STM4 F0 I/O MULTI MODE cOC12/STM4 single-mode intermediate reach without APS/MSP redundancy cOC12/STM4 single-mode intermediate reach with APS/MSP redundancy cOC12/STM4 single-mode long reach cOCx/STMx F0 cOC12 STM4 F0 I/O SINGLE MODE 2. 2. 0 15. 0. x 17 2. 2. 0 15. 0. x 15 cOCx/STMx F0 COC12 F0 APS SINGLE MODE 6. 1. 3, 7. 0. 2, 7. 2. 0 15. 0. x 19 cOCx/STMx F0 cOC12 STM4 LONG HAUL 2. 2. 0 15. 0. x 21 Channelized T1 CT1 CT1 CT1 FULL I/O 1. 1. 0 7. 3. x 23 Channelized T3 Copyright © 2010, Juniper Networks, Inc. 3 E Series End-of-Life Module Guide Table 1: End-of-Life Modules (continued) Actual or Predicted Last JunosE Support 7. 0. x 14. 0. x Combination Name CT3 (3 ports) CT3/T3 12 (12 ports) Line Module Label CT3 CT3/T3-F0 I/O Module Label CT3/T3 I/O CT3/T3 12 I/O First JunosE Support 1. 0. 0 3. 2. 0 Page 24 25 E3 E3 ATM E3 Frame (3 ports) E3 Frame (12 ports) E3 ATM E3 FRAME COCX-F3 E3 I/O E3 I/O E3-12 FRAME I/O 1. 1. 0 1. 1. 0 4. 0. 2 7. 1. x 7. 0. x 14. 0. x 26 27 28 Fast Ethernet FE-2 (2 ports) FE-8 (8 ports) (128 MB) Only line module is EOL. [. . . ] See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release 8. 0. x and earlier. LEDs Alarms, errors, and events 32 Copyright © 2010, Juniper Networks, Inc. GE 1000Base-SX Module Combination (1 Port) (128 MB) GE 1000Base-SX Module Combination (1 Port) (128 MB) This module combination is no longer supported because the line module has reached end-of-life. However, the I/O module is still supported. Line module label I/O module label Number of I/O ports Software release GE/FE GE I/O SFP · · · · · · 1 active, 1 redundant First supported: 2. 0. 0 Final supported: 5. 2. x 130 W Gigabit Ethernet The GE SFP I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cable lengths. The transceivers on this GE I/O module are 1000Base-SX compliant. ASIC Ethernet (IEEE 802. 3z) 1000Base-SX See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX14xx models ERX310 router SRP-5G+ SRP-10G SRP-40G SRP-40G PLUS SRP-SE10G Not applicable Description · · · · · Type Capability Software features Model compatibility · · · · · · · · · SRP module compatibility Module redundancy support Copyright © 2010, Juniper Networks, Inc. 33 E Series End-of-Life Module Guide Cables and connectors · · LC full duplex Tx power: · · min: ­9. 5 dBm max: ­4 dBm · · Center wavelength: 850 nm Rx input power: · · min: ­17 dBm max: ­3 dBm · · · · · Rated for 275 m (300 yards) over 62. 5-micron core cable Rated for 550 m (601 yards) over 50-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information. See ERX Module Guide, Appendix B, Module LEDs. See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release 8. 0. x and earlier. LEDs Alarms, errors, and events 34 Copyright © 2010, Juniper Networks, Inc. GE 1000Base-ZX Module Combination (1 Port) (128 MB) GE 1000Base-ZX Module Combination (1 Port) (128 MB) This module combination is no longer supported because the line module has reached end-of-life. However, the I/O module is still supported. Line module label I/O module label Number of I/O ports Software release GE/FE GE I/O SFP · · · · · · 1 active, 1 redundant First supported: 2. 0. 0 Final supported: 5. 2. x 130 W Gigabit Ethernet The GE SFP I/O module uses a range of small form-factor pluggable (SFP) transceivers to support different modes and cable lengths. The transceivers on this GE I/O module are 1000Base-ZX compliant. ASIC Ethernet (IEEE 802. 3z) 1000Base-ZX See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX14xx models ERX310 router SRP-5G+ SRP-10G SRP-40G SRP-40G PLUS SRP-SE10G Not applicable Description · · · · · Type Capability Software features Model compatibility · · · · · · · · · SRP module compatibility Module redundancy support Copyright © 2010, Juniper Networks, Inc. 35 E Series End-of-Life Module Guide Cables and connectors · · LC full duplex Tx power: · · min: ­3 dBm max: 2 dBm · · Center wavelength: 1550 nm Rx input power: · · min: ­23 dBm max: ­3 dBm · · · · Rated for 70 km (43. 4 miles) over 10-micron core cable See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information. See ERX Module Guide, Appendix B, Module LEDs. See Monitoring Ethernet Interfaces in the Configuring Ethernet Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release 8. 0. x and earlier. LEDs Alarms, errors, and events 36 Copyright © 2010, Juniper Networks, Inc. HSSI Module Combination HSSI Module Combination Line module label I/O module label Number of I/O ports Software release HSSI-3F HSSI-3 I/O · · · · · · · · · 3 First supported: 3. 1. 0 Final supported: 7. 3. x 60 W High-speed serial interface Non-ASIC Up to 44. 736 MHz data rate HDLC Framing See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX1410 router SRP-5G SRP-5G+ SRP-10G Not applicable Standard HSSI connector: 2-row, 50-pin, receptacle header with rails and latch blocks 50 feet (15. 24 m) maximum cable length See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information. See ERX Module Guide, Appendix B, Module LEDs. See Monitoring Interfaces in the Configuring HSSIs chapter of the JunosE Physical Layer Configuration Guide for Release 8. 0. x and earlier. Description Type Capability Software features Model compatibility · · · · · · · SRP module compatibility Module redundancy support Cables and connectors · · LEDs Alarms, errors, and events · · Copyright © 2010, Juniper Networks, Inc. 37 E Series End-of-Life Module Guide IPSec Service Module Combination Line module label I/O module label Number of I/O ports Software release IPSEC SERVICE No I/O module · · · · · · · · Not applicable First supported: 4. 0. 2 Final supported: 14. 0. x 130 W IPSec Tunnel Service EFA ASIC IPSec tunnels See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX14xx models ERX310 router SRP-5G+ SRP-10G SRP-40G SRP-40G PLUS SRP-SE10G Multiple IPSec Service modules provide redundancy. Not applicable See ERX Module Guide, Appendix B, Module LEDs. See Monitoring Tunnel-Service Interfaces in JunosE Physical Layer Configuration Guide, Chapter 6, Managing Tunnel-Service and IPSec-Service Interfaces. Description Type Capability Software features Model compatibility · · · · · · · · · · · · SRP module compatibility Module redundancy support Cables and connectors LEDs Alarms, errors, and events 38 Copyright © 2010, Juniper Networks, Inc. OC3 (Dual-Port) Multimode Module Combination OC3 (Dual-Port) Multimode Module Combination Line module label I/O module label OC3 OC3 I/O MULTI MODE Software release · · · First supported: 1. 0. 0 Final supported: 4. 1. x Obsolete, no longer supported Description Copyright © 2010, Juniper Networks, Inc. 39 E Series End-of-Life Module Guide OC3 (Dual-Port) Single-Mode Module Combination Line module label I/O module label OC3 OC3 I/O SINGLE MODE Software release · · · First supported: 1. 0. 0 Final supported: 4. 1. x Obsolete, no longer supported Description 40 Copyright © 2010, Juniper Networks, Inc. OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (128 MB) OC3/STM1 ATM Multimode Without APS/MSP Redundancy Module Combination (128 MB) This module combination is no longer supported because the line module has reached end-of-life. However, the I/O module is still supported. Line module label I/O module label OCx/STMx ATM or OCx/STMx /DS3-ATM OC3-4 I/O MULTI MODE Number of I/O ports Software release · · · · · · · · · 4 First supported: 2. 0. 0 Final supported: 5. 2. x 130 W Unchannelized, concatenated OC3/STM1 for ATM ASIC OC3/STM1 ATM:AAL5 See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX14xx models ERX310 router SRP-5G+ SRP-10G SRP-40G SRP-40G PLUS SRP-SE10G 1:N redundancy NOTE: Line module redundancy is not supported on the ERX310 router. Description Type Capability Software features Model compatibility · · · · · · · · · · SRP module compatibility Module redundancy support Copyright © 2010, Juniper Networks, Inc. 41 E Series End-of-Life Module Guide Cables and connectors · · SC full duplex connector Tx power: · · min: ­19 dBm max: ­14 dBm · · Center wavelength: 1310 nm Rx input power: · · min: ­30 dBm max: ­14 dBm · Rated for 2 km (1. 2 miles) over 62. 5-micron core cable with an optical loss of 0­9 dB or 50-micron core cable with an optical loss of 7 dB See ERX Hardware Guide, Chapter 5, Cabling ERX Routers for more information. See ERX Module Guide, Appendix B, Module LEDs. [. . . ] Not applicable See ERX Module Guide, Appendix B, Module LEDs. See Monitoring Tunnel-Service Interfaces in the Managing Tunnel-Service and IPSec-Service Interfaces chapter of the JunosE Physical Layer Configuration Guide for Release 8. 0. x and earlier. Description Type Capability Software features Model compatibility · · · · · · · · · · SRP module compatibility Module redundancy support Cables and connectors LEDs Alarms, errors, and events · · · Copyright © 2010, Juniper Networks, Inc. 65 E Series End-of-Life Module Guide X. 21/V. 35 Module Combination Line module label I/O module label Number of I/O ports Software release X. 21/V. 35 X. 21/V. 35 I/O · · · · · · · · 16 First supported: 2. 10. 1, 3. 3. 2 Final supported: 7. 3. x 60 W X. 21/V. 35 synchronous serial interface Non-ASIC HDLC framing See ERX Module Guide, Appendix A, Module Protocol Support for information about the layer 2 and layer 3 protocols and applications that this module combination supports. ERX7xx models ERX1410 router SRP-5G SRP-5G+ SRP-10G Not applicable 200-pin proprietary socket on I/O module DB15 X. 21 or DB34 V. 35 at remote end Serial signals can travel a limited distance without significant degradation. Slower serial signals can travel farther without degradation than faster serial signals. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual JUNIPER NETWORKS E SERIES BROADBAND SERVICES ROUTERS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag