[. . . ] NETWORK CODEC
DMNC40
INSTRUCTIONS
ENCODE
DECODE
HOLD
IN 1
IN 2
POWER
CF
PLAY
STOP
HOLD
SELECT
P inP
This instruction book is mode from 100% recycled paper.
LST0177-001A
SICHERHEITSHINWEISE
WARNUNG: Zur Verringerung des Risikos von Feuer bzw. elektrischem Schlag darf dieses Gert nicht Regen oder Feuchtigkeit ausgesetzt werden.
Dieses Gert sollte nur mit 220 V bis 240 V Wechselstrom verwendet werden. ACHTUNG: Keine andere Stromversorgung verwenden, um elektrischen Schlag und Feuergefhrdung zu verhten. Hinweis:
Das Leistungsschild (Typennummerschild) befindet sich auf der Rckwand.
Warnung zur Lithiumbatterie
Die in diesem Gert verwendete Batterie kann bei falscher Behandlung das Risiko von Feuer oder chemischen Verbrennungen mit sich bringen. [. . . ] However, this is not a malfunction of the unit. Video input is to be inputted in VIDEO IN 1 or VIDEO IN 2 on the camera side. see page 61.
The echo canceller is set to OFF when shipped. To use echo canceller for bidirectional audio communication,
26
(3) Streaming system (ISMA compliant)
When using the unit in the ISMA Server mode, an ISMA-compliant player is required. For details of ISMA compliant player, please consult the person in charge of professional equipment at your nearest JVC authorized service agent.
CH-1 AUDIO LEVEL
CH-2
PROFESSINAL
ND FILTER ON OFF
IRIS
FOCUS
AUTO MANU
DV CAMCORDER GY-DV300
PUSH AUTO
VIDEO OUT AUDIO OUT
OPEN
AUDIO IN
ALARM
RS485 RS232C
VIDEO IN
SERIAL 1 SERIAL 2
SERVICE CONTROL
I S M A S e r ve r mode
( Page 41)
AUDIO OUT IN AC IN L
VIDEO OUT
VIDEO IN 1
VIDEO IN 2
100BASE-TX
LOOP THRU
LOOP THRU
100BASE-TX
R
RESERVED OPEN OPEN
00:02:30
Network
ISMA compliant player
Memo
Make sure to set each IP address differently. Use of a dedicated network is recommended. Up to 5 players can be connected for unicast. Audio is compatible with MPEG-4 AAC-LC stereo.
27
Preparations
Step 1 Connection/Installation (Continued)
1-1 Connection Examples (Continued)
Caution when connecting different modes
For teleconference application, set units to Teleconference mode. For remote monitoring application, set units to Camera/Monitor mode. Connecting units in different application modes will result some problems as following: Teleconference mode - Monitor mode Teleconference side: Audio of the monitor side is played back. Monitor side: Video and audio of the teleconference side are played back. Teleconference mode - Camera mode Teleconference side: Video and audio of the camera are played back. Camera side: Audio of the teleconference side is played back. Teleconference mode - ISMA Server mode Teleconference side: Video is played back and audio will be noise. Streaming side: No playback Monitor mode - ISMA Server mode Monitor side: Video is played back and audio will be noise. Streaming side: No playback Camera mode - ISMA Server mode Camera side: Audio will be noise. Streaming side: No playback Monitor mode - Monitor mode Only audio will be played back. Camera mode - Camera mode Only audio will be played back.
Observing the video and audio using another DM-NC40 unit (observer mode)
Observing stream is available by connecting another DM-NC40 unit to working DM-NC40. Camera mode accepts observing at the time of shipment. For teleconference mode, a setting change using API is required to accept observing. ( Page 66) Remote Monitoring system (Camera mode and Monitor mode)
Observing is available by connecting from Monitor mode to Camera mode that is connected already to another Monitor mode. (At this time, ENCODE display lamp: OFF, DECODE display lamp: ON, SELECT button light: OFF (operation disabled), PinP button light: OFF (operation disabled) on the observing unit. ) * The automatic recovery feature does not work with observing unit. [. . . ] To continue operation from Telnet, perform the connection procedure again after the unit reboot.
Exiting Tenet Enter "exit".
Memo
If Telnet cannot be exited properly due to network or PC problems, reconnection of Tenet will fail since the unit
keeps previous Telnet connection. Reconnection will be possible in 10 minutes by timeout of previous telnet connection. Telnet can be disconnected by rebooting the unit.
67
Operations
About the Alarm
In camera mode, image files are recorded to CF card when the CF button is pressed or alarm is inputted to the ALARM INPUT port. (To see the image, see "Operating the CF Card", page 61)
Settings
Select input video Alarm input settings CF card settings
Select input video for JPEG in the ENCODE PARAMETERS screen. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE JVC DM-NC40
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.