Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KAWAI EP308S. We hope that this KAWAI EP308S user guide will be useful to you.
Lastmanuals help download the user guide KAWAI EP308S.
Detailed instructions for use are in the User's Guide.
[. . . ] denotes an operation that should be carried out. The example instructs the user to remove the power cord plug from the AC outlet.
Read all the instructions before using the product. WARNING - When using electric products, basic precautions should always be followed, including the following.
potential could result in death WARNING Indicates ainjury if thehazard thathandled incorrectly. or serious product is
The product should be connected to an AC outlet of the specified voltage.
120V
230V
240V
G If you are going to use an AC power cord, make sure that its has the correct plug shape and conforms to the specified power voltage. [. . . ] OVERDRIVE
sense sense intensity drive
0 -100 (%) 0 -100 (%) 0 -100 (%) 0 -100 (%)
wet balance wet balance send level wet balance
REVERB parameter list
REVERB Time rev. time 0. 3 - 5. 0S rev. time rev. time rev. time rev. time rev. time rev. time 0. 3 - 5. 0S 0. 3 - 3. 0S 0. 3 - 3. 0S 0. 3 - 3. 0S 0. 3 - 3. 0S 0. 3 - 3. 0S REVERB Depth send level send level send level send level send level send level send level
1. PLATE
Note: When EFX/REVERB depth is set to 0 while the EFX/REVERB button is active, the EFX/REVERB button will blink to indicate that the EFX/ REVERB is turned ON but the depth is set to 0. EFX rate and REVERB time are effective to internal zone only. EFX type, EFX rate and EFX depth are common to all internal zones. If the selected zone is set to BOTH, changing the value for EFX depth or REVERB depth affects for both internal and external sections. If you want different settings for internal and external sections, first enter the edit mode by pressing the MENU button and press the EFFECT button. Now you can select internal or external zone with ZONE SELECT button. (See page 29 for details. )
5. 2 EQ (EQUALIZER)
The EP308S contains a four-band graphic equalizer to shape the overall tone of the sound. The EQ affects all zones at the same time. However, each SETUP can have its own EQ setting that affects the internal sounds only. Be sure that the EQ button in the CONTROL KNOBS section is lit. Use the CONTROL KNOBS to change the MIDI continuous controller information assigned to each knob as described below. Each parameter of the Control Change has an adjustable range from 0 to 127. When the selected zone is set to INT or BOTH, the display shows the parameter names.
1PAN STN VbR VbD 0 0 0 0
When the selected zone is set to EXT, the display shows the MIDI CC numbers.
3010 070 076 077 64 64 64 64
The default parameters assigned for each knob are as follows.
A: #10 Panpot (PAN) B: #70 Sustain Level (STN) C: #76 Vibrato Rate (VbR) D: #77 Vibrato Depth (VbD) Note: If the selected zone is set to BOTH, changing the MIDI CC# parameters affects for both internal and external sections. If you want different settings for internal and external sections, enter the edit mode by pressing the MENU button and select internal or external section with ZONE SELECT button. (See page 29 for details. )
Changing MIDI CC parameter
Press and hold the MIDI CC# button. The MIDI CC# button starts blinking and the cursor in the display moves up to the parameter name.
1PAN STN VbR VbD 0 0 0 0
Use the CONTROL KNOBS to change the parameters. After changing the parameter, press the MIDI CC# button again. The MIDI CC# button stops blinking and the cursor in the display moves down to the value.
27
Note: When the selected zone is set to INT, only the following parameters can be selected. 10 11 70 71 76 77 78 93 Panpot Expression Sustain Level Resonance Vibrato Rate Vibrato Depth Vibrato Delay Chorus Depth PAN EXP STN RSN VbR VbD VbY ChD
When the selected zone is set to BOTH and the internal section is selected in edit mode, the parameters not available for INT section show as XXX.
1015 STN VbR VbD Ixxx 0 0 0
28
29
6. MENU
The MENU buttons allow access to the edit parameters in the EP308S. This collection of settings together with other editable parameters can be stored as a SETUP. [. . . ] If you have an older Macintosh OS, please use an appropriate MIDI interface and MIDI cables when connecting the EP308S to a Macintosh computer. NOTE: When both MIDI jacks and USB jack are connected, USB has priority. When connecting USB cable to the EP308S, first connect the USB cable and then turn the power of the EP308S on. It may take some time to start communication when the EP308S is connected to the computer via USB. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KAWAI EP308S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KAWAI EP308S will begin.