User manual KAZ 18150

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KAZ 18150. We hope that this KAZ 18150 user guide will be useful to you.

Lastmanuals help download the user guide KAZ 18150.


Mode d'emploi KAZ 18150
Download
Manual abstract: user guide KAZ 18150

Detailed instructions for use are in the User's Guide.

[. . . ] Arrange cord such that it will not be tripped over. Do not use air cleaner where combustible gases or vapors are present. Do not expose the air cleaner to rain, or use near water, in a bathroom, laundry area or other damp location. The air cleaner must be used in its upright position. [. . . ] The monitors have the ability to indicate the amount of expected filter life used. Once a filter has reached the end of its expected life, its light will remain on until it is RESET. You may unplug the air cleaner without interrupting the filter monitors. The Intelli-CheckTM Filter Monitors count the expected filter life based on an assumed average operating time of 12 hours a day on medium speed. Therefore, it will indicate replacement of the Pre-filter in about 3 months, and the HEPA filter in about 1 year and 9 months. Depending upon your individual usage (environment, hours and speed of operation), you may need to check and replace the filters more or less frequently. To CHECK Expected Filter Life Usage When the unit is turned on, quickly press the filter monitor button. The pre-filter light will flash up to 3 times and the HEPA filter light will flash up to 4 times, depending upon how much expected filter life has been used. PREFILTER: 1 flash 2 flashes 3 flashes Remains on HEPA FILTER: 1 flash 2 flashes 3 flashes 4 flashes Remains on = = = = from new, up to 1/3 expected life used up between 1/3 and 2/3 expected life used up between 2/3 and all of expected life used up time to replace pre-filter = = = = = from new, up to 1/4 expected life used up between 1/4 and 1/2 expected life used up between 1/2 and 3/4 expected life used up between 3/4 and all of expected life used up time to replace HEPA filter To RESET Filter Monitor When the filter monitor light remains on, it is time to replace the filter and reset the filter monitor. With the unit powered on, press and hold the filter monitor button down for approximately 5 seconds until the light turns off. Replacement Filter s. . . Model Number Series HEPA Filter Part Number Carbon Pre-filter Part Number 18150 21500 38002 (contains 8 replacements) Replacement filters may be purchased from the retail store where you purchased the product. If you cannot locate one in your area, please call our Consumer Relations Dept. at (800) 332-1110 for assistance, email us at service@honeywell. com or visit us at www. honeywell. com/yourhome. Filter Replacement Intervals. . . CAUTION: Do not attempt to wash either the activated carbon pre-filter or the HEPA filter. They are not washable and washing will damage the filters. With proper maintenance, your Honeywell air cleaner is designed to provide years of high efficiency air cleaning. Our recommendations regarding filter replacement intervals are intended as guidelines only, as life expectancy of any filter media is dependent on the concentration of the contaminants to which the system is exposed. If there are sources of large amounts of contaminant generation (such as dust from woodworking or heavy smoking) the useful life of the filter media in your air cleaner may be reduced and require early replacement. The primary HEPA filter should remain effective for 1 to 3 years, depending upon the environment in which the air cleaner is operating. Honeywell recommends changing the HEPA filter based upon operation conditions­every 3 years for light usage, 2 years for normal usage and 1 year for heavy usage. The activated carbon pre-filter helps protect the HEPA filter by capturing lint and other large particles, and helps reduce normal household odors. It should be checked monthly and replaced at least every 3 months. If there are heavy concentrations of odors, smoke, or large particles in the home, you may need to change the pre-filter more often. We DO NOT recommend operating the air cleaner without the activated carbon pre-filter or without following the filter replacement guidelines. [. . . ] Do not attempt to repair the unit yourself as it may cause injury, and the warranty does not cover damage resulting from unauthorized attempts to repair or from any use not in accordance with this manual. 5 Year Limited Warranty. . . Honeywell HEPA Air Cleaners Model No. 18150 Series This product has been engineered and crafted with great care for your satisfaction. Be sure to fill out and return the enclosed card within 10 days of purchase. This limited warranty applies to repair or replacement of product found to be defective in material or workmanship within 5 years of the date of purchase. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KAZ 18150

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KAZ 18150 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag