User manual KENWOOD TS-480HX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KENWOOD TS-480HX. We hope that this KENWOOD TS-480HX user guide will be useful to you.

Lastmanuals help download the user guide KENWOOD TS-480HX.


Mode d'emploi KENWOOD TS-480HX
Download

You may also download the following manuals related to this product:

   KENWOOD TS-480HX (6571 ko)

Manual abstract: user guide KENWOOD TS-480HX

Detailed instructions for use are in the User's Guide.

[. . . ] PC CONTROL COMMAND REFERENCE FOR THE TS-480HX/ SAT TRANSCEIVER © 2003/11/28 09 08 07 06 05 04 03 02 01 00 PC CONTROL COMMAND ABOUT THIS REFERENCE All descriptions in this PC CONTROL COMMAND reference are for the users convenience only. KENWOOD will not support or warrantee this documentation in any way. CONTROL OPERATION Most computers handle data in the form of "bits" and "bytes". A bit is the smallest piece of information that a computer can handle. This is the most convenient form for most computer data. [. . . ] 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 ; 7 8 9 10 4 P1 4 5 P1 5 6 ; 6 7 8 9 10 7 8 9 10 Parameters: P1 010 (min. ) ~ 060 (max. ) [in WPM] K 1 S 2 Read K 1 S 2 Answer K S 11 PC CONTROL COMMAND KY Converts the characters into Morse code. 1 2 3 P1 13 P2 23 P2 3 ; 3 P1 4 ; 5 6 7 8 9 4 P2 14 P2 24 P2 4 5 P2 15 P2 25 P2 5 6 P2 16 P2 26 P2 6 7 P2 17 P2 27 P2 7 8 P2 18 P2 28 ; 8 9 9 P2 19 P2 29 K 11 Se t P2 21 P2 1 Read Y 12 P2 22 P2 2 Parameters: P1 0: Character buffer is available 10 1: Character buffer is not available (Answer command only. A space must be used for the Set P2 command. ) P2 20 Enter characters and numbers. Available characters are: P2 ABCDEFGHIJKLMNOPQRSTUVWXYZ " " (space) 0123456789 30 "'()*+, ­. /:=?Special characters: The following ASCII characters can be used in place of the special CW codes. 10 BT=[, AR=_, AS=<, HH=#, SK=>, KN=], BK=\, SN=% The fixed 24-byte length is used for the P2 parameter. " " (space) character must be used for the unused characters. These space characters will not be converted. If all P2 parameter characters are spaces, the transceiver stops sending the message. K 1 Y 2 10 Answer K Y LK Se t Sets and reads the key lock function status. 1 2 3 P1 3 ; 3 P1 4 P2 5 ; 6 7 8 9 10 4 P2 4 5 ; 5 6 7 8 9 10 6 7 8 9 10 L 1 K 2 Parameters: P1 0: Frequency lock function OFF 1: Frequency lock function ON P2 0: Tuning control lock function OFF 1: Tuning control lock function ON Read L 1 K 2 Answer L K LM Set Sets and reads the VGS-1 or electric keyer recording status. 1 2 3 P1 3 ; 3 P1 4 P2 5 P3 6 P3 7 P3 8 ; 9 10 4 P2 4 5 ; 5 6 7 8 9 10 6 7 8 9 10 L 1 M 2 Read L 1 M 2 Answer L M Parameters: P1 1 ~ 3: CH (Recording Channel) number P2 0: Stop recording (Set command only) 0: Recording function is inactive 1: Ready for recording 2: Start recording (Busy status while recording) P3 000 ~ 060: Remaining recording time in seconds (Voice mode) 000 ~ 100: Recorded message capacity as a percentage (CW) Parameters: P1 0: Always 0 for the TS-480 (Memory bank number). P2 00 ~ 99: Channel number MC Se t Recalls or reads the Memory channel. 1 2 3 P1 3 ; 3 P1 4 P2 5 P2 6 ; 7 8 9 10 4 P2 4 5 P2 5 6 ; 6 7 8 9 10 7 8 9 10 M 1 C 2 Read M 1 C 2 Answer M C MD Set Recalls or reads the operating mode status. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 M 1 D 2 Read M 1 D 2 Answer M D Parameters: P1 0: No mode (Not used for the TS-480) 1: LSB 2: USB 3: CW 4: FM 5: AM 6: FSK 7: CWR (CW Reverse) 8: Tune (Not used for the TS-480) 9: FSR (FSK Reverse) 12 PC CONTROL COMMAND MF Set Sets or reads Menu A or B. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 Parameters: P1 0: Menu A 1: Menu B M 1 F 2 Read M 1 F 2 Answer M F MG Set Sets or reads the Microphone gain status. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 ; 7 8 9 10 4 P1 4 5 P1 5 6 ; 6 7 8 9 10 7 8 9 10 Parameters: P1 000 (min. ) ~ 100 (max. ) M 1 G 2 Read M 1 G 2 Answer M G ML Set Sets or reads the TX Monitor function output level. 1 2 3 P1 3 ; 3 P1 4 P1 5 P1 6 ; 7 8 9 10 4 P1 4 5 P1 5 6 ; 6 7 8 9 10 7 8 9 10 Parameters: P1 000: TX Monitor function OFF 001 (min. ) ~ 009 (max. ) M 1 L 2 Read M 1 L 2 Answer M L MR Set Reads the Memory channel data. 1 2 3 4 5 6 7 8 9 10 1 Read 2 3 P1 3 P1 13 P4 23 P9 33 P13 43 P16 4 P2 4 P2 14 P4 24 P9 34 P13 44 P16 5 P3 5 P3 15 P4 25 P10 35 P13 45 P16 6 P3 6 P3 16 P4 26 P10 36 P13 46 P16 7 ; 7 P4 17 P4 27 P10 37 P13 47 P16 8 9 10 M 1 R 2 8 P4 18 P5 28 P11 38 P13 48 P16 9 P4 19 P6 29 P12 39 P14 49 P16 10 P4 20 P7 30 P13 40 P14 50 ; M 11 P4 21 Answer P8 31 P13 41 P15 R 12 P4 22 P8 32 P13 42 P16 Parameters: P1 0: RX frequency, 1: TX frequency P2 Always 0 for the TS-480. P3 00 ~ 99: Memory channel number P4 Frequency in Hz (11-digit). P7 0: OFF, 1: TONE, 2: CTCSS P8 Tone Number. Memory channel 90 ~ 99: P1=0 (start frequency), P1=1 (end frequency) 13 PC CONTROL COMMAND MW Store the data to the Memory channel. 1 2 3 P1 13 P4 23 P9 33 P13 43 P16 3 4 P2 14 P4 24 P9 34 P13 44 P16 4 5 P3 15 P4 25 P10 35 P13 45 P16 5 6 P3 16 P4 26 P10 36 P13 46 P16 6 7 P4 17 P4 27 P10 37 P13 47 P16 7 8 P4 18 P5 28 P11 38 P13 48 P16 8 9 P4 19 P6 29 P12 39 P14 49 P16 9 10 P4 20 P7 30 P13 40 P14 50 ; 10 M 11 P4 21 Set P8 31 P13 41 P15 1 Read W 12 P4 22 P8 32 P13 42 P16 2 1 Answer 2 3 4 5 6 7 8 9 10 Parameters: P1 0: RX frequency, 1: TX frequency P2 Always 0 for the TS-480. P3 00 ~ 99: Memory channel number P4 Frequency in Hz (11-digit). 0: Lockout OFF, 1: Lockout ON P7 0: OFF, 1: TONE, 2: CTCSS P8 Tone Number. [. . . ] 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 Parameters: P1 0: Tone function OFF 1: Tone function ON T 1 O 2 Read T 1 O 2 Answer T O TS Set Sets or reads the TF-SET function status. 1 2 3 P1 3 ; 3 P1 4 ; 5 6 7 8 9 10 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 Parameters: P1 0: TF-SET function OFF 1: TF-SET function ON T 1 S 2 Read T 1 S 2 Answer T S TX Set Sets the transceiver in TX mode. 1 2 3 P1 3 4 ; 4 5 6 7 8 9 10 5 6 7 8 9 10 T 1 X 2 Parameters: P1 0: Normal (SEND) transmission using MIC input 1: DTS transmission using ANI input 2: TX Tune transmission If no P1 parameter is specified, P1=0 is used. P2 Always 0 for the TS-480. Read 1 Answer 2 3 P2 4 ; 5 6 7 8 9 10 T X 21 PC CONTROL COMMAND TY Set Sets or reads the microprocessor fimware type. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KENWOOD TS-480HX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KENWOOD TS-480HX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag