User manual KEYENCE LV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KEYENCE LV. We hope that this KEYENCE LV user guide will be useful to you.

Lastmanuals help download the user guide KEYENCE LV.


Mode d'emploi KEYENCE LV
Download
Manual abstract: user guide KEYENCE LV

Detailed instructions for use are in the User's Guide.

[. . . ] Safety features Laser ON alarm indicator The laser ON alarm indicator will start flashing after power is turned on. The lamp will remain ON for as long as the laser light is emitting. This alarm indicator can be seen even when wearing protective goggles. LASER ON MODE SET Laser ON alarm indicator General Purpose Digital Laser Sensor PH A B BH % LV Series Instruction Manual Laser emission stop input (LV-21A/21AP/51M/51MP/11A) Laser emission can be stopped by short-circuiting between the purple and blue (GND) wires when LV-21A, LV-51M or LV-11A used. When LV-21AP or 51MP is used, short-circuit between the purple and brown (12 to 24 V DC) wires to stop laser emission. 5 V DC Main circuit Purple Blue (Short circuit current 1 mA max. ) Label location ¡LV-H32 Aperture Protect housing label Aperture label TH WI S LIE . 11 MP 1040 CO D T AN . [. . . ] Detect the DOWN edge received light change. State Receive all light MODE SET PH A B MODE SET BH % M once lightly. · DIFFERENTIATION (UP edge detection) PH A B BH % · DIFFERENTIATION (DOWN edge detection) MODE SET PH A B BH % Interrupt half light 250 Interrupt all light 250 Differentiation Mode Detection (page 5) 4. Selecting display shift MODE SET PH A B BH % 4. Switching display shift By pressing S once, the received light intensity display will shift to a value of 0. Also, fine adjustments of display shift can be done using or . Received light intensity after shift MODE SET PH BH % PH A B BH % 0 500 1-2. Registering the standard light intensity MODE SET 1-2. Registering the standard light intensity :( A for both outputs A and B ) B Press the S button in the state that no target is set. When the SET indication flashes quickly, the setting is completed. Press M once lightly. A B Amount of shift NOTE Setting values will also shift. Press M once lightly. *To set the shift value to 0, press together. 5. Selecting hold mode MODE SET PH A B BH % and 1-3. Changing the number of display digits or . PH BH % A B MODE SET 5. Hold mode switching Select a hold mode to use for 1-3. Changing the number of display digits :( A for both outputs A and B ) B The last digit of digital display can be set to non-display. Select a value to be displayed in the digital display (green) by using or . When A-5 is selected in 1-1 · NO HOLD MODE SET PH A B BH Display is not held % PH BH Press M once lightly. · PEAK HOLD MODE SET Press M once lightly. PH A B BH % Peak value is held on the display PH BH MODE SET PH A B BH % MODE SET PH A B BH % · BOTTOM HOLD MODE SET PH A B BH % To "2. Selecting power mode" Minimum value is held on the display PH BH 6. Selecting timer mode MODE SET PH A B BH % 6. Switching timer mode Select a timer mode to use for MODE SET Note or . Set to this mode for regular detection work. Use for output OFF delay Use for output ON delay Use for one-shot output When the standard light intensity is set, the detection mode is fixed to "Standard Detection 1" · NO TIMER · OFF DELAY once lightly. PH A B BH % MODE SET PH A B BH % Press M MODE SET · ON DELAY Selecting no timer PH A B BH % MODE SET · ONE SHOT 7. Timer setting Set the timer for MODE SET PH A B BH % PH A B BH % 7. Timer setting MODE SET PH A B BH % or PH A B BH . MODE SET % Press M once lightly. Min. 9999 ms *It is possible to perform detection work while changing mode settings. [. . . ] (For further information on connecting several units contact KEYENCE) Placing the amplifier cable together in the same conduit with power lines or high voltage lines may cause detection errors due to interference or sensor damage. For this reason, always isolate the amplifier cable from these lines. If using a commercial switching regulator, make sure to ground both the frame ground terminal and ground terminal. Do not use the LV Series outdoors, or in any location where extraneous light can directly enter the light receiving surface. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KEYENCE LV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KEYENCE LV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag