If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA AUTO METER IVF. We hope that this KONICA MINOLTA AUTO METER IVF user guide will be useful to you.
Lastmanuals help download the user guide KONICA MINOLTA AUTO METER IVF.
Manual abstract: user guide KONICA MINOLTA AUTO METER IVF
Detailed instructions for use are in the User's Guide.
[. . . ] With the latitude display function, the Flash Meter VI can simultaneously display the results of both incident light measurement and spot light measurement. It provides a clear and simple graphical decision process for determining the exposure suited to the nature of the photograph. With the analyze scale, you can determine the proportion of flash light and ambient light in a single flash light measurement. The Flash Meter VI provides a memory function capable of storing up to 10 measured values; an averaging function that calculates an average exposure from stored measurement data; and a brightness difference function that displays deviation from the standard exposure. [. . . ] The reading is also displayed on the analog scale. The proportion of flash light illuminating the composition is shown on the analyze scale. Pressing the CLR button clears the measurement data. If no flash is connected to the sync terminal, or if the flash does not fire normally because it is not fully charged, the meter cannot take a flash light measurement. Before starting measurement, make sure that the flash is connected to the sync terminal and the flash has been fully charged. The f-number corresponding to the shutter speed set in step 4 is displayed on the digital readout as well as on the analog scale with a pointer ( ). The proportion of flash light illuminating the composition is shown on the analyze scale. Example: The display shows a reading of F8. 0 + 0. 9 stops, and the proportion of ambient light to flash light is about 1:1.
E28
E29
Basic Operation
Basic Operation
When measuring flash light using a sync cord (CORD mode), the flash may fail to fire (e. g. if the trigger voltage of the flash is too low). In this case, take a reading without sync firing the flash (NON CORD mode).
If the f-number reading is outside the meter's display range, "FNo. " blinks and the display shows either " O " (over-range error) or " U " (under-range error). At the same time, the over-range/under-range error indicator ( or ) appears on the analog scale.
If the f-number reading exceeds or falls below the meter's measuring range, the display shows "E. o. " (over-range error) or "E. u. " (under-range error).
E30
E31
Basic Operation
Basic Operation
2. At the same time, the over-range/under-range error indicator ( or ) appears on the analog scale.
E34
If the f-number reading exceeds or falls below the meter's measuring range, the display shows "E. o. " (over-range error) or "E. u. " (under-range error). E35
Basic Operation
Basic Operation
Using the up/down dial to change the shutter speed to 1/15, we can see how this change will affect the mix of ambient and flash light. The aperture has changed to F4. 03 and now, only one quadrant is lit up. This indicates that the proportion of flash light is now only 25% (ambient:flash ratio =3:1). A photograph taken under these conditions will be influenced more strongly by the tungsten light (orange) and less strongly by the flash light (white).
Light Ratio Analyze function
For flash light measurement, the Flash Meter VI uses a method of measuring flash light/ambient light separately. The proportion of ambient light and flash light to the total exposure is indicated on the quadrant analyze scale.
How to read the flash/ambient light ratio
: 0 ~ 16% :17 ~ 41% :42 ~ 58% :59 ~ 83% :84 ~ 100%
Whenever you take a flash light reading, the analyze scale is displayed on the LCD data panel. After a reading, you can also do a simulation to see how changes to the shutter speed affect the proportions of ambient light and flash light. The analyze scale shows the proportion of flash light in the total exposure reading as one of five levels.
On the other hand, increasing the shutter speed (within the range of sync) will have the opposite effect-photos will be more strongly influenced by flash light (white) than ambient light.
Example of reading, display and simulation Assume that a tungsten lamp is used as the ambient light source. Reading of F2. 80 at a shutter speed of 1/60 sec. Two quadrants are lit up on the display, indicating that the proportion of flash light is approx. 50% (ambient:flash ratio =1:1).
A photograph taken under these conditions will not be strongly influenced by either the tungsten light (orange) or the flash light (white).
This simulation is based on controlling the ambient light by varying the shutter speed. [. . . ] Nothing particular
Only the accessories shown above may be used with the Flash Meter VI.
E74
E75
Handling Instructions
1) If the meter is used in the rain, at the seashore, or near a volcano, it may become rusty or corroded due to water or corrosive gas. In such situations, be careful to protect the meter as much as possible. 2) Do not subject the meter to shock or vibration. For protection, store the meter in its case when carrying it. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA AUTO METER IVF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.