If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA CA-310. We hope that this KONICA MINOLTA CA-310 user guide will be useful to you.
Lastmanuals help download the user guide KONICA MINOLTA CA-310.
Manual abstract: user guide KONICA MINOLTA CA-310DATASHEET
Detailed instructions for use are in the User's Guide.
[. . . ] Specifications
Item Receptor Measurement area Acceptance angle Measurement distance Display Luminance range Chromaticity Luminance Measurement range Accuracy (for white)*1 Repeatability(2) *1 CA-310 (LED Universal Measuring Ø27 Probe) CA-310 (LED Universal Measuring Ø10 Probe) Detector: Silicon photo cell Ø10 mm Ø27 mm ±2. 5° ±5° 30±10 mm 30±5 mm 2 0. 0001 to 3000 cd/m2 0. 0001 to 1000 cd/m Displayed in 4 or 3-digit value (Can be chosen) 0. 0150 to 3000 cd/m2 0. 0050 to 1000 cd/m2 0. 0050 to 0. 0999 cd/m2 ±4%±0. 0015 cd/m2 0. 0150 to 0. 2999 cd/m2 ±4%±0. 0045 cd/m2 0. 1000 to 9. 999 cd/m2 ±3%±0. 0010 cd/m2 0. 3000 to 29. 99 cd/m2 ±3%±0. 0030 cd/m2 10. 00 to 1000 cd/m2 ±2%±0. 0010 cd/m2 30. 00 to 3000 cd/m2 ±2%±0. 0030 cd/m2 0. 0050 to 0. 0999 cd/m2 1% + 0. 0010 cd/m2 0. 0150 to 0. 2999 cd/m2 1% + 0. 0030 cd/m2 0. 1000 to 0. 9999 cd/m2 0. 2% + 0. 0010 cd/m2 0. 3000 to 2. 999 cd/m2 0. 2% + 0. 0030 cd/m2 1. 000 to 1000 cd/m2 0. 1%+0. 0010 cd/m2 3. 000 to 3000 cd/m2 0. 1% + 0. 0030 cd/m2 0. 0500 to 1000 cd/m2 0. 1500 to 3000 cd/m2 0. 0500 to 4. 999 cd/m2 ±0. 005 for white 0. 1500 to 14. 99 cd/m2 ±0. 005 for white 5. 000 to 19. 99 cd/m2 ±0. 004 for white 15. 00 to 59. 99 cd/m2 ±0. 004 for white 20. 00 to 1000 cd/m2 ±0. 003 for white 60. 00 to 3000 cd/m2 ±0. 003 for white 120 cd/m2 ±0. 002 for white 120 cd/m2 ±0. 002 for white (±0. 004 for monochrome)*2 (±0. 004 for monochrome)*2 0. 0500 to 0. 0999 cd/m2 0. 010 0. 1500 to 0. 2999 cd/m2 0. 010 0. 1000 to 0. 1999 cd/m2 0. 004 0. 3000 to 0. 5999 cd/m2 0. 004 2 0. 2000 to 0. 4999 cd/m 0. 002 0. 6000 to 1. 499 cd/m2 0. 002 0. 5000 to 1000 cd/m2 0. 001 1. 500 to 3000 cd/m2 0. 001 CA-310 (LED Flicker Measuring Ø27 Probe) CA-310 (LED Flicker Measuring Ø10 Probe) Ø27 mm ±2. 5° 30±10 mm 0. 0001 to 1000 cd/m2 Ø10 mm ±5° 30±5 mm 0. 0001 to 3000 cd/m2
NEW
Display Color Analyzer
Support for LED backlights
Chromatcity
Measurement range Accuracy *1 (temperature:23°±2°, relative humidity: (40±10)%)) Repeatability(2) *1
Flicker Contrast method
Measurement range Display range Accuracy
Repeatability(2) Flicker JEITA Measurement range method *3 Accuracy Repeatability(2) xyLV Measurement speed*4 Flicker Contrast Flicker JEITA *3 Digital Analog LCD
Display
SYNC mode Object under measurement Memory channel Analyzer function Interface Multi-point Measurement
Operating temperature/humidity range Storage temperature/humidity range
Input voltage range Size/weight Main body Probe
0. 0050 to 1000 cd/m2 0. 0150 to 3000 cd/m2 0. 0050 to 0. 0999 cd/m2 ±4%±0. 0015 cd/m2 0. 0150 to 0. 2999 cd/m2 ±4%±0. 0045 cd/m2 0. 1000 to 9. 999 cd/m2 ±3%±0. 0010 cd/m2 0. 3000 to 29. 99 cd/m2 ±3%±0. 0030 cd/m2 10. 00 to 1000 cd/m2 ±2%±0. 0010 cd/m2 30. 00 to 3000 cd/m2 ±2%±0. 0030 cd/m2 0. 0050 to 0. 0999 cd/m2 1% + 0. 0010 cd/m2 0. 0150 to 0. 2999 cd/m2 1% + 0. 0030 cd/m2 0. 1000 to 0. 9999 cd/m2 0. 2% + 0. 0010 cd/m2 0. 3000 to 2. 999 cd/m2 0. 2% + 0. 0030 cd/m2 1. 000 to 1000 cd/m2 0. 1%+0. 0010 cd/m2 3. 000 to 3000 cd/m2 0. 1% + 0. 0030 cd/m2 0. 0500 to 1000 cd/m2 0. 1500 to 3000 cd/m2 0. 0500 to 4. 999 cd/m2 ±0. 005 for white 0. 1500 to 14. 99 cd/m2 ±0. 005 for white 5. 000 to 19. 99 cd/m2 ±0. 004 for white 15. 00 to 59. 99 cd/m2 ±0. 004 for white 20. 00 to 1000 cd/m2 ±0. 003 for white 60. 00 to 3000 cd/m2 ±0. 003 for white 120 cd/m2 ±0. 002 for white 120 cd/m2 ±0. 002 for white (±0. 004 for monochrome)*2 (±0. 004 for monochrome)*2 0. 0500 to 0. 0999 cd/m2 0. 010 0. 1500 to 0. 2999 cd/m2 0. 010 0. 1000 to 0. 1999 cd/m2 0. 004 0. 3000 to 0. 5999 cd/m2 0. 004 2 0. 2000 to 0. 4999 cd/m 0. 002 0. 6000 to 1. 499 cd/m2 0. 002 0. 5000 to 1000 cd/m2 0. 001 1. 500 to 3000 cd/m2 0. 001 5 cd/m2 or higher 15 cd/m2 or higher 0. 0 ~ 999. 9 % ±1 % (Flicker frequency: 30 Hz AC/DC 10% sine wave) ±2 % (Flicker frequency: 60 Hz AC/DC 10% sine wave) 1 % (Flicker frequency: 20 to 65 Hz AC/DC 10% sine wave) 15 cd/m2 or higher 5 cd/m2 or higher ±0. 5 dB (Flicker frequency: 30 Hz AC/DC 10% sine wave) 0. 3 dB (Flicker frequency: 30 Hz AC/DC 10% sine wave) 0. 0050 to 0. 0999 cd/m2 4(3. 5) times/sec. 0. 0150 to 0. 2999 cd/m2 4(3. 5) times/sec. [. . . ] Screens shown are for illustration purpose only. The specifications and drawings given here are subject to change without prior notice.
Uniformity
3D television
108 98 88
28 208 136 126 116
213
10
70 110 127
30. 2 44 L = 2000 or 5000
L
47. 5
30. 2 44 L = 2000 or 5000
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. Improper connection may cause a fire or electric shock.
17
47. 5
L
236
Certificate No : YKA 0937154 Registration Date : March 3, 1995
Certificate No : JQA-E-80027 Registration Date : March 12, 1997
©2010 KONICA MINOLTA SENSING, INC.
9242-4885-16 BAIAPK Printed in Japan
Enables high-accuracy adjustment of LED-backlit LCD TVs white balance and greatly improves work efficiency.
White balance adjustment has advanced even further!
Our previous Display Color Analyzer CA-210 could adjust the white balance of LED-backlit LCD TVs to xy=0. 010, but the new Display Color Analyzer CA-310 enables adjustment to xy=0. 003 so colors are even more true, as can be seen below. White balance adjustment of LED -backlit LCD TVs
Reduces errors due to LED emission distribution variations to less than 1/3.
Variations in the emission distribution of LED backlights result in individual differences of about 10nm in peak intensity wavelength. If LED-backlit LCD TVs with such individual differences are adjusted using conventional color analyzers, color differences of close to 0. 010 on the xy chromaticity diagram may occur. But the CA-310 has sensor sensitivities that more closely match the CIE 1931 color-matching functions, enabling the color difference in the same case to be reduced to around 0. 003, suppressing errors to less than 1/3. 0. 008
Relative Intensity
Variations in the emission distribution of LED backlights
0. 006 0. 004 0. 002
Measurement errors for LED backlights
0. 008 0. 006 0. 004 0. 002 0. 000 -0. 002 -0. 004
LED wavelength variation
CA-310 adjustment results CA-210 adjustment results
xy=0. 010 xy=0. 003 xy=0. 000 xy=0. 003 xy=0. 010
LED wavelength variation
Relative Intensity
Target color
Wavelength (nm)
-9 nm -6 nm -5 nm -0. 006 -4 nm 0. 000 -3 nm -2 nm -0. 008 -0. 002 -1 nm -0. 008 -0. 006 -0. 004 -0. 002 0. 000 0. 002 0. 004 0. 006 0. 008 1 nm -0. 004 2 nm 4 different peak *Errors (differences from true values) for white LEDs withnm
-9 nm -6 nm -5 nm -4 nm -3 nm -2 nm -1 nm 1 nm 2 nm 4 nm
-0. 006 -0. 008
Wavelength (nm)
wavelengths when measured using CA-310. User calibration to standard LED performed.
-0. 008 -0. 006 -0. 004 -0. 002 0. 000 0. 002 0. 004 0. 006 0. 008
Enables high-speed measurement of even extremely low luminances down to 0. 005 cd/m2
Sensor noise reduction technology has been used to enable measurements even in the extremely low luminance region around 0. 005 cd/m2 at speeds as fast as 4 times per second. This allows the high-speed high-accuracy measurement essential for manufacturing high-grade displays. [. . . ] CA-310 Standard Hood for CA-210/310 CA-H10 (Standard) or Small Hood for CA-210/310 CA-HS10 (Standard) Standard Lens Cap for CA-210/310 CA-H11 (Standard) or Small Lens Cap for CA-210/310 CA-HS11 (Standard) PC Software for Color Analyzer CA-SDK (Standard)*2
Sample software Color
Ø10 Probe Ø27 Probe CA-PSU32 (2m) CA-P32 (2m) CA-PSU35 (5m) CA-P35 (5m)
Applicability for different display types
Transmissive / semi-transmissive LCD LCD Rear Screen Projector DLP CRT
AC Power Cord (Standard)
Active Matrix Driven Passive Matrix Driven Active Matrix Driven Passive Matrix Driven
* × * × × × * × × ×
* × * × × × * × × ×
Select the desired probe from the Probe Variations table at right. (Illustration shows the LED Universal Measuring Ø27 Probe. )
OLED PDP FED
Active Matrix Driven Passive Matrix Driven
(LED Flicker Measuring Probes are unsuitable for measurements of CRTs. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA CA-310 Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service. Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA MINOLTA CA-310 will begin.