If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA DI551 DI650 ADD INFO UTILITIES. We hope that this KONICA MINOLTA DI551 DI650 ADD INFO UTILITIES user guide will be useful to you.
Lastmanuals help download the user guide KONICA MINOLTA DI551 DI650 ADD INFO UTILITIES.
Manual abstract: user guide KONICA MINOLTA DI551 DI650 ADD INFO UTILITIES
Detailed instructions for use are in the User's Guide.
[. . . ] Table of Contents
Di551/Di650 Additional Information for Web Utilities The following items refer to the to the Di551/Di650 User Manual, Section: Network Function and Section: Key Operator Mode. Please use the web browser of Internet Explorer 5. 5 / Netscape 4. 7 or later to access the Web Utilities.
1 2
Revised
1. 1 Setting E-Mail Transmission Function (Environment Setup) . . . Function (Environment Setup). . . . . . . . . . . . . . . . . . . . . . . . . . . . Function Setting menu window . . . . . . . . . . . . . . . . . . . . . . . . . 2-2 To add E. K. C. [. . . ] Function Setting menu item to jump to the desired window.
5 Click on [Apply].
The Count Reset Confirmation window will be displayed.
6 Click on [Apply] to immediately reset the counters to zero.
The message "Setting was changed" will be displayed. If an error message is displayed after clicking on [Apply], a counter has not been reset due to a machine operation in progress. The machine must be in an idle state when you click on [Apply].
7 Click on [Back] to return to the E. K. C. Data List window.
Di551/Di650 Additional information
2-9
2
To delete E. K. C. Function Setting menu window
or from the menu in any subsequent window. Data List window will be displayed.
3 Click on the check box(es) to select the E. K. C. If
all the data are to be cleared, click on [SelectAll]. The "Another user count" in the list indicates the count accumulated for the jobs performed by non-registered users. This data cannot be edited other than resetting the counter.
2-10
Di551/Di650 Additional information
Added
2
4 Click on the radio button (a white circle) heading the "Delete selected
item(s) (Except for Another user count). " To cancel deleting the E. K. C. Function Setting menu item to jump to the desired window.
5 Click on [Apply].
The Delete Confirmation window will be displayed.
6 Click on [Apply] to immediately delete the data.
The message "Setting was deleted" will be displayed. If an error message is displayed after clicking on [Apply], a data has not been deleted due to a machine operation in progress. The machine must be in an idle state when you click on [Apply].
7 Click on [Back] to return to the E. K. C. Data List window, or any menu
item to jump to the desired window.
Di551/Di650 Additional information
2-11
2
To set the E. K. C. function
Added
1 Display the E. K. C. Function Setting menu
window or from the menu in any subsequent window. Function Setting window will be displayed.
3 Click on the radio button (white circle) of the desired selection item(s)
so that a black dot appears in it. To restore the previous setting, click on [Reset]. function setting, click on [Back].
2-12
Di551/Di650 Additional information
Added
2
4 Click on [Apply].
The change made in the settings will be transmitted immediately for the user operations. If an error message is displayed after clicking on [Apply], a setting has not been completed due to a machine operation in progress. The machine must be in an idle state when you click on [Apply].
5 Click on [Back] to return to the E. K. C. Function Setting menu window
or any menu item to jump to the desired window.
Di551/Di650 Additional information
2-13
2
2. 2
Added
Setting Scan Transmission Function (Environment Setup)
Perform the Key Operator setting concerning the transmission of the scanned image data using the web browser. For details of the Scan Transmission Setting, contact your service representative.
NOTE Specifications for Scan Transmission Setting ! [. . . ] # Use numbers, letters (capital letters only), and four symbols: (, ), , and / only to specify NAME. # Use up to 6 digits numbers (0 - 9) only to specify LIMIT (0 999, 999). E-mail data setting file: Begin the file with #IP_EMAIL. # A line should include ENTRY NAME and E-MAIL ADDRESS, being separated by a tab. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA DI551 DI650 ADD INFO UTILITIES
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.