User manual KONICA MINOLTA DIMAGE SCAN SPEED

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA DIMAGE SCAN SPEED. We hope that this KONICA MINOLTA DIMAGE SCAN SPEED user guide will be useful to you.

Lastmanuals help download the user guide KONICA MINOLTA DIMAGE SCAN SPEED.


Mode d'emploi KONICA MINOLTA DIMAGE SCAN SPEED
Download
Manual abstract: user guide KONICA MINOLTA DIMAGE SCAN SPEED

Detailed instructions for use are in the User's Guide.

[. . . ] Thank you for purchasing the Minolta Dimâge Scan Speed. The Dimâge Scan Speed is a dual format film scanner capable of scanning 35mm and, with the optional AD-10 APS Adapter, Advanced Photo System film. This manual has been designed to help you understand the operation of your scanner. Please read this manual thoroughly to realize all the benefits of your scanner. [. . . ] Click on to view the histograms for the preview image. and hold Click on in the prescan window. The Histogram Dialog Box -- Names of Parts Control image White point button Black point button Gray point button Output histogram button RGB synchro button Load settings button Save settings button Shadow sliders Midtone slider Highlight sliders Output level sliders Input level sliders Preview image Dimâge Scan Speed 35 IMAGE CORRECTION ­ HISTOGRAM Setting the White, Black, and Gray Points Properly setting an image's white and black points will usually correct the colour cast and midtone distribution. Properly setting the gray point will correct the colour balance. · Changes are automatically applied to the preview image. 1. Click on , then click on the tone in the control or prescan image that should be scanned as the brightest neutral white in your image. · The pointer will change to . · The RGB brightness values of the selected tone will be changed to 255. 2. Click on , then click on the tone in the control or prescan image that should be scanned as the darkest neutral black in your image. · The pointer will change to . · The RGB brightness values of the selected tone will be changed to 0. 3. Click on , then click on the tone in the control or prescan image that should be scanned as a neutral tone. · The pointer will change to . · The colour balance of the image is shifted to make the selected tone neutral. · The selected tone's brightness value does not change. Setting the gr ay point is not necess ary for most images. 36 IMAGE CORRECTION ­ HISTOGRAM Brightness and Contrast Changes - RGB Synchro When RGB synchro is selected, moving the levels sliders remaps the pixel values without changing the colour balance. Correcting the highlight and shadow values with the histogram sliders, may produce better results on images without neutral highlights or shadows. If the histogram contains large flat line areas. . . Click on . · Changes applied to one colour channel will be reflected in the other two. 2. Click on and move the input level highlight and shadow sliders to the edges of the flat line area. · Changes are automatically applied to the preview image. · Values to the right of the highlight slider will be scanned as pure white (level 255). Values to the left of the shadow slider will be scanned as pure black (level 0). Input Level Histograms Input level highlight sliders moved to the edge of the flat line area. 3. Click on and slide the output level sliders until the preview image has the desired image contrast. · Click on to view a full screen display of the control and preview windows. 4. Click on and hold to view the output level histograms. Output Level Histograms The brightness level for the curren tly selected slide r is displayed nex t to the histogram. Pixel values have been spread to better utilize the brightness range. Continued on the following page. Dimâge Scan Speed 37 IMAGE CORRECTION ­ HISTOGRAM Colour Balance Adjustment - Individual Channels Changing the slider positions for individual channels affects the colour balance of the output image. 1. Click on to deselect RGB Synchro. Input Level Histograms 2. Click on and move the R, G, and B sliders to the desired locations. · Changes are automatically applied to the preview image. · Click on to view a full screen display of the control and preview windows. The red input level highlight slider is moved to the edge of the red flat line area. 3. Click on and hold to view the output level histograms. Output Level Histograms Only the red pixel values have been remapped. [. . . ] Drag the DS_Speed Profile into the ColorSyncTM Profiles folder in the Preferences folder. Drag the ColorSyncTM filter to the Adobe Photoshop Filters folder located inside the Plug-ins folder. 66 TROUBLE SHOOTING SYMPTOM or MESSAGE The computer will not start up after connecting the scanner. SOLUTION · Shut down the computer and all the devices in your SCSI chain, then check the SCSI cables, SCSI ID connection, power cord, and SCSI ID. · Make sure the plug-in module has been placed in the correct folder. See page 12. DS_Speed does not appear in the Acquire drop down list. "Could not establish connection with scanner. " · Indicator lamp is off - Turn the Dimâge Scan Speed on, then restart your system. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA DIMAGE SCAN SPEED

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA MINOLTA DIMAGE SCAN SPEED will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag