User manual KONICA MINOLTA PSNETCARE UM 551

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA MINOLTA PSNETCARE UM 551. We hope that this KONICA MINOLTA PSNETCARE UM 551 user guide will be useful to you.

Lastmanuals help download the user guide KONICA MINOLTA PSNETCARE UM 551.


Mode d'emploi KONICA MINOLTA PSNETCARE UM 551
Download
Manual abstract: user guide KONICA MINOLTA PSNETCARE UM 551

Detailed instructions for use are in the User's Guide.

[. . . ] x Table of contents Table of contents 1 System Requirements 1. 1 1. 2 1. 3 Network Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Client . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-4 2 Installing and Starting Up the Server 2. 1 Installing the Server . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] This reduces the speed of the search; however, a more reliable result can be achieved. SNMP Setting section Time Out: Type in the length of time (in milliseconds, 1 second = 1000 milliseconds) to wait for a response when searching for devices. Retries: Type in the number of attempts that are made when a search for devices fails. SNMPv1 Table: Add or remove read community names and port numbers used when searching for devices compatible with SNMPv1. ! Detail For details, refer to "To add settings used with a search for devices compatible with SNMPv1" on page 6-14 and "To remove settings used with a search for devices compatible with SNMPv1" on page 6-15. SNMPv3 Table: Add or remove user names, context names, and port numbers used when searching for devices compatible with SNMPv3. PSNetCare 6-11 6 Configuring PageScope Net Care Settings ! Detail For details, refer to "To add settings used with a search for devices compatible with SNMPv3" on page 6-15 and "To remove settings used with a search for devices compatible with SNMPv3" on page 6-16. 2 Note When searching for devices compatible with SNMPv3, the security level must be set to No Auth/No Priv. Device Discovery section Auto Discovery: Select this check box to enable automatic rediscovery of devices on the network. Auto Discovery Interval (hour): When Auto Discovery above is checked, enter the auto discovery interval time in hours. Last Discovery Start Time: Shows the start time of device re-discovery. Last Discovery Finish Time: Shows the finish time of device re-discovery. Start Discovery: Click the Start button to start device discovery. Enable Generic Device Discovery: Select this check box for discovery of RFC-1759 Printer-MIB compatible devices. 6-12 PSNetCare Configuring PageScope Net Care Settings To add a network to the discovery range 6 1 On the Discovery Setting screen, click the [Add] button in the Discovery Network / Range section. Network setting items are shown in the Input Network Range section. 2 3 4 Type the IP address of the network you want to add into the Network Address boxes. Type the subnet mask value of the network you want to add into the Subnet Mask box. If you want to change the host address discovery range, input the start address into the Discovery From box, and the end address into the Discovery To box. ­ In the HTML mode, no values are input automatically into the Discovery From and Discovery To boxes, and they can be left blank, if you want. Leaving these boxes blank searches within the range specified by the Network Address and Subnet Mask boxes. If you want to specify a range, input the start address into the Discovery From box and the end address into the Discovery To box. 5 After everything is the way you want, click the [Apply] button. To clear all settings you have made on the setup screen, click the [Cancel] button. PSNetCare 6-13 6 6 Configuring PageScope Net Care Settings If you also want discovery to find other maker's RFC-1759 Printer-MIB compatible devices, select the check box next to the Enable Generic Device Discovery option, and then click the [Apply] button. To remove a network from the discovery range 1 2 In the Discovery Network / Range list, click the network you want to remove from the discovery range and then click the [Remove] button. In the Java mode, click the [OK] button in the confirmation dialog box that appears. The confirmation dialog box does not appear in the HTML mode. This selected network is deleted from the list. When automatic device discovery fails % Click the [Start] button in the Device Discovery section to restart network device discovery. Clicking the [Start] button while device auto discovery is in progress causes network discovery to restart from the beginning. To add settings used with a search for devices compatible with SNMPv1 1 In the SNMP Setting section of the Discovery Setting screen, click the [Add] button beside the SNMPv1 Table. The SNMPv1 Setting screen appears. 6-14 PSNetCare Configuring PageScope Net Care Settings 6 2 3 Type the settings into the Read Community Name and Port Number boxes. To cancel the operation, click the [Cancel] button instead. To remove settings used with a search for devices compatible with SNMPv1 1 2 Select the Select check box to the left of the settings that you wish to delete from the SNMPv1 Table, and then click the [Remove] button. In Java mode, a message appears, requesting confirmation to delete the settings. Click the [OK] button to delete the selected settings. The confirmation message does not appear in HTML mode. 2 Note If all settings are deleted, devices compatible with SNMPv1 can no longer be searched for. To add settings used with a search for devices compatible with SNMPv3 1 In the SNMP Setting section of the Discovery Setting screen, click the [Add] button beside the SNMPv3 Table. The SNMPv3 Setting screen appears. PSNetCare 6-15 6 2 3 Configuring PageScope Net Care Settings Type settings into the User Name, Context Name, and Port Number boxes. To cancel the operation, click the [Cancel] button instead. To remove settings used with a search for devices compatible with SNMPv3 1 2 Select the Select check box to the left of the settings that you wish to delete from the SNMPv3 Table, and then click the [Remove] button. In Java mode, a message appears, requesting confirmation to delete the settings. [. . . ] If you are using the HTML mode, select Server Setting in the list, and then click the [Go] button. Double-click the [E-mail Setting] icon, then the [E-mail Function / Server icon] (single-click in the HTML mode) in the Server Setting menu tree. 2 3 4 PSNetCare Select the check box next to the Counter Reader. 10-9 10 10. 5 Obtaining and Viewing Device Counter Information Specifying Initial PageScope Net Care Server Settings for Using This Function--2 This procedure is performed from the PageScope Net Care server. Procedure Specify the following settings in order to use this function. 1 Click the down arrow button above the pane along the left side of the window, and then select Counter Reader in the list that appeared. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA MINOLTA PSNETCARE UM 551

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA MINOLTA PSNETCARE UM 551 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag