User manual KONICA CA-210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CA-210. We hope that this KONICA CA-210 user guide will be useful to you.

Lastmanuals help download the user guide KONICA CA-210.


Mode d'emploi KONICA CA-210
Download

You may also download the following manuals related to this product:

   KONICA CA-210 BROCHURE (2286 ko)

Manual abstract: user guide KONICA CA-210

Detailed instructions for use are in the User's Guide.

[. . . ] Display Color Analyzer CA-210 INSTRUCTION MANUAL Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as result of incorrect use of the instrument. Denotes a sentence regarding safety warning or note. Read the sentence carefully to ensure safe and correct use. Denotes a sentence regarding safety precautions for risk of fire. [. . . ] Never press the following keys during user calibration. Doing so will cancel user calibration and activate the mode corresponding to the pressed key. ( 0-CAL , MODE , MR , MEMORY CH , , ) The following alphabet will appear at the "*" position on the LCD display section according to the selected calibration mode. d : Matrix calibration with Konica Minolta's calibration standard 6500K h : Matrix calibration with Konica Minolta's calibration standard 9300K a : White calibration (user calibration) m : Matrix calibration (user calibration) CH01 EXT [ A* P1U ] "*" position <Error Messages in LCD Display Section> . . . For other error messages, refer to page 103. "E3" (When the key is pressed in the calibration value input screen) E3 x y Lv P1 · Cause : Incorrect calibration values are set. Incorrect calibration val3300 0000 100. 0 ues mean the following. 2 1­x­y 0 3 Values which are beyond the instrument's calculation capability or contradicting values · Action : Enter correct values and then press the key. key is pressed in the calibration value input screen) "E5" (When the CH01 U-CAL E5 *W *R G *B · Cause 1: Calibration values (x, y, Lv) for white color have not been entered. Action : Enter the calibration values (x, y, Lv) for white color and then press the key. · Cause 2: Calibration values for only some of R, G and B have been entered. Action : If you are going to perform white calibration, enter the values for W only. (Restart from step 4, where you were asked to press the key. ) If you are going to perform matrix calibration, enter values for the colors whose values have not been entered, and then press the key. key is pressed in the calibration value input screen) "E6" (When the CH01 U-CAL E6 *W *R *G *B · Cause : Incorrect calibration values are set. Incorrect calibration values mean the following. "E6" will appear if the calculation results obtained when calculation for matrix calibration is performed are inappropriate. · Action : Enter correct values and then press the key. 57 Settings Section <Calibration Mode and LCD> Analyzer Mode 1. About Analyzer Mode <What is Analyzer Mode?> Analyzer measurement mode is provided for adjustment of the display's white balance. The measured colors are expressed in output of each R, B and G monochromatic light based on the display's analyzer mode RGB emission characteristic (input to the instrument) and the target color (W). Thus, adjusting the emission intensity of R causes the measured value of R only to change, and measured values for B and G remain unchanged This mode is useful when you adjust the emission intensity of R, B and G to match the target color (W). The following measured values will be displayed when the display's emission intensity (emission intensity of R, B and G monochrome lights) and the target color (W) are set and measurement is performed in analyzer mode. · Digital display section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . R, B, G : Outputs of the currently measured monochrome lights R, B and G in ratio (%) to those of the specified target color (W) · Analog display section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Press the CH and desired memory channel. Press the key. keys to select the Memory channel CH01 EXT [ Ad P1U ] 1 Press the 2 Press the 3 Press the 4 Press the key to display the menu selection screen. key to confirm the selection. Probe no. Ad P1U ] 3. Press the screen. key to open the ID name input MENU : SELECT PUSH SPACE KEY 4. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CA-210

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CA-210 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag