User manual KONICA CM-3600D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CM-3600D. We hope that this KONICA CM-3600D user guide will be useful to you.

Lastmanuals help download the user guide KONICA CM-3600D.


Mode d'emploi KONICA CM-3600D
Download

You may also download the following manuals related to this product:

   KONICA CM-3600D BROCHURE (1647 ko)

Manual abstract: user guide KONICA CM-3600D

Detailed instructions for use are in the User's Guide.

[. . . ] n Numerical UV Control for calibration and measurements. n Soft-flash mode to avoid triplet adsorption in fluorescent materials. The Innovative CM-3600d Spectrophotometer Brings You Highest Quality Levels in Color Measurement along with Unsurpassed Versatility, User Comfort and Low Cost! Enhanced Performance Technology Konica Minolta Innovative Optical System The CM-3600d is equipped with Minolta Innovative Optical System technology. For users, this means high accuracy and repeatability, improved performance, additional features, simple operation, and - low, affordable pricing. [. . . ] This technology also provides: Performance Fast, simultaneous measurement of Specular Included and Specular Excluded components (SCI/SCE) Fast, Instantaneous numerical UV adjustment enables UV-included, UV-excluded, and UV-adjusted data to be obtained simultaneously Precise inter-instrument agreement. All CM-3600d's meet published inter-instrument agreement. Full range of application coverage Whatever your sample looks like, with the CM-3600d you can measure it!Reflectance of opaque samples, Transmittance of transparent liquids or solids and Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is truly versatile. Versatility Full wavelength range 360-740nm with 10nm pitch Large (6") sphere; d/8° geometry Reflectance and transmittance sample measurements Changeable measurement areas (ø4mm, ø8mm, or ø25. 4mm) View finder design for easy sample viewing Compact and lightweight For high-accuracy color control The newly designed Monolith Polychromator Unit consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array. 1. Numerical Gloss Control Instead of using a mechanically driven gloss trap, the CM-3600d is equipped with a patented numerical Gloss (SCl/SCE) control system. By sequentially firing two flashes, within a few seconds the system provides both SCI and SCE values for each sample. specular component included SCE. . . . . . . . . specular component excluded Reliability High reliability design with fewest moving parts of any benchtop spectrophotometer Transmittance Measurement-The CM-3600d employs the d/0° geometry (diffused lighting, 0° viewing), which conforms to ISO, DIN, CIE, and ASTM standards. Reflectance Measurement-The CM-3600d employs d/8° geometry (diffused lighting, 8° from normal viewing) which conforms to JlS, ISO, DIN, CIE and ASTM standards. SpectraMagic NX TM (Optional) Supports Windows®2000/XP Konica Minolta Innovative Optical System Technology Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before. Multiple measurement area selection Bright and clear sample viewing system The retro mirror's reflected and illuminated sample viewing screen minimizes fatigue and allows trouble-free sample observation. To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25. 4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens. 2. Numerical UV Control To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, never seen before: The measured values of two sequentially fired flashes, one with full UV energy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UVactivated fluorescence sample. · Windows® is a trademark of Microsoft Corporation in the USA and other countries. TM TM TM TM Dimensions 89 (Units:mm) Maintenance free technology and ruggedness concept The CM-3600d is equipped with maintenance-free technology and solid state components to withstand rugged conditions. The monolith polychromator unit assures highest durability and stability. With one exception (Observing Lens), the CM-3600d does not use any moving parts. Furthermore, each CM-3600d passes a hard endurance test program to comply with KONICA MlNOLTA's highest quality standards in accordance with ISO-9001. 35 378 POWER ON OFF UV-adjusted data 208 17 244 54 System Diagram Cell CM-A97 (2mm) Cell CM-A98 (10mm) Cell CM-A99 (20mm) Plastic Cell Plastic Cell Plastic Cell CM-A130 CM-A131 CM-A132 (2mm; set for 100) (10mm; set for 100) (20mm; set for 100) Personal Computer RS-232C Cable IF-A12 (for IBM PC) RS-232C Cables IF-A13 to IF-A15 Target Mask CM-A107 ( 4mm) Transmittance Specimen Holder CM-A96 Transmittance. Zero Calibration Plate CM-A100 Target Mask CM-A106 ( 8mm) Unit Driver CM-A108 AC Adapter AC-A12 AC Adapter AC-A21 (for Korea) SpectraMagic NX CM-S100w TM Spectrophotometer CM-3600d Target Mask CM-A105 ( 25. 4mm) (with floppy disk containing calibration data) White Calibration Plate CM-A103 Standard accessories Optional accessories Zero Calibration Box CM-A104 Dust Cover CM-A110 Accessory Case CM-A109 Color Tiles Specifications Illumination/ observation system Reflectance;d/8 (diffused illumination, 8-degree viewing), equipped with simultaneous measurement of SCI (specular component included) / SCE (specular component excluded) Conforms to CIE No. 15, lSO7724/1, ASTME1164, DIN5033 Teil7 and JIS Z8722 condition C standard. Transmittance : d/0 (diffused illumination, 0degree viewing) Conforms to CIE No. 15, ASTME1164 and DIN5033 Teil7 standard. Silicon photodiode array (dual 40 elements) Diffraction grating 360 to 740nm 10nm Approx. 10nm 0 to 200%; resolution: 0. 01% ø152mm Pulsed xenon lamps (X4) Approx. [. . . ] Silicon photodiode array (dual 40 elements) Diffraction grating 360 to 740nm 10nm Approx. 10nm 0 to 200%; resolution: 0. 01% ø152mm Pulsed xenon lamps (X4) Approx. 4 seconds;when SCI/SCE measured Network construction for color control either within an organization or between organizations High inter-instrument agreement between the same Konica Minolta model and also among all CM models (benchtops and portables): CM-2000 series, CM-3000 series, This inter-instrument agreement is ideal when multiple units will be used for color control either within an organization or between organizations. CM-3700d Light-receiving element Spectral separation device Wavelength range Wavelength pitch HaIf bandwidth Reflectance range Sphere size Light source Measurement time Minimum interval between measurements Measurement/ illumination area CM-3500d LAV : ø25. 4mm/ø30mm MAV: ø8mm/ø11mm (Selectable) SAV : ø4mm/ø7mm Repeatability Spectral reflectance: Standard deviation within 0. 1% Colorimetric values: Standard deviation within E*ab0. 02 Inter instrument Mean E*ab0. 15 (LAV/SCI) Average for 12 BCRA Series II color tiles agreement compared to values measured with master body. Temperature Spectral reflectance: Within ±0. 10%/°C dependence Color difference: Within E*ab 0. 05/°C UV adjustment Instantaneous numerical adjustment UV cut filter 400nm cutoff and 420nm cutoff Transmittance Width: 133mm; depth: approx. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-3600D

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-3600D will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag