Detailed instructions for use are in the User's Guide.
[. . . ] For users, this means high accuracy and repeatability, improved performance, additional features, simple operation, and - low, affordable pricing. This technology also provides: For high-accuracy color control The newly designed Monolith Polychromator Unit
consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array.
Performance
Full range of application coverage
Whatever your sample looks like, with the CM-3600d you can measure it! [. . . ] This technology also provides: For high-accuracy color control The newly designed Monolith Polychromator Unit
consists of a diffraction grating with a full wavelength range, 360-740 nm, at 10nm pitch, and 10nm half-band width, both for sample and reference light, and dual-channel sensor array.
Performance
Full range of application coverage
Whatever your sample looks like, with the CM-3600d you can measure it!Reflectance of opaque samples, Transmittance of transparent liquids or solids and Diffuse Transmittance of translucent materials such as plastics - the CM-3600d is truly versatile.
Fast, simultaneous measurement of Specular Included and Specular Excluded components (SCI/SCE) Fast, Instantaneous numerical UV adjustment enables UV-included, UV-excluded, and UV-adjusted data to be obtained simultaneously Precise inter-instrument agreement. All CM-3600d spectrophotometers meet published inter-instrument agreement.
1. Numerical Gloss Control
Instead of using a mechanically driven gloss trap, the CM-3600d and CM-3610d feature a patented numerical Gloss (SCl/SCE) control system. By sequentially firing two flashes, within a few seconds the system provides both SCI and SCE values for each sample. SCI SCE specular component included specular component excluded
Versatility
Full wavelength range 360-740nm with 10nm pitch Large (6") sphere; d/8° geometry Reflectance and transmittance sample measurements Changeable measurement areas (ø4mm, ø8mm, or ø25. 4mm) View finder design for easy sample viewing Compact and lightweight
Transmittance Measurement-The CM-3600d employs the d/0° geometry (diffused lighting, 0° viewing), which conforms to ISO, DIN, CIE, and ASTM standards.
Reflectance Measurement-The CM-3600d employs d/8° geometry (diffused lighting, 8° from normal viewing) which conforms to JlS7 ISO, DIN, CIE and ASTM standards.
Reliability
High reliability design with fewest moving parts of any benchtop spectrophotometer
Konica Minolta Innovative Optical System Technology
Konica Minolta's Innovative Optical System, including Numerical Gloss Control and Numerical UV Control, opens the way to unlimited application versatility at a price level never seen before.
CM-3610d Vertical Model
Multiple measurement area selection
To cover all kinds of samples, the CM-3600d gives you the choice among three aperture sizes: LAV 25. 4mm, MAV 8mm and SAV 4mm with precise measurement spot adjustment by a motorized observing lens.
2. Numerical UV Control
To replace the time-consuming traditional UV measurement system that utilizes moving filters, the CM-3600d introduces yet another patented numerical calculation system, which is also part of the CM-3610d: The measured values of two sequentially fired flashes, one with full UV energy and one with UV cut-off filter at either 400 or 420 nm are combined to obtain the spectral characteristics, and the respective whiteness and tint value of any UV-activated fluorescence sample. Transmittance : d/0 (diffused illumination, 0-degree viewing) Conforms to CIE No. 15, ASTME1164 and DIN5033 Teil7 standard. Silicon photodiode array (dual 40 elements) Diffraction grating 360 to 740nm 10nm Approx. 10nm 0 to 200%; resolution: 0. 01% ø152mm 4 pulsed xenon lamps Approx. 5 seconds LAV : ø25. 4mm/ø30mm MAV : ø8mm/ø11mm (Selectable) SAV : ø4mm/ø7mm Spectral reflectance: Standard deviation within 0. 1% Colorimetric values: Standard deviation within E*ab0. 02 Mean E*ab0. 15 (SCI) Average for 12 BCRA Series II color tiles compared to values measured with master body. Spectral reflectance: Within ±0. 10%/°C Color difference: Within E*ab 0. 05/°C Instantaneous numerical adjustment 400nm cutoff and 420nm cutoff Width: 133mm; depth: approx. 17mm Transmission sample holder (Optional accessory): Sample holder for both plate-shaped and liquid samples (removable) RS-232C, D-SUB 9-pin (female) terminal AC120V/230V 50/60Hz (Using included AC adapter) 13 to 33°C, relative humidity 80% or less (at 33°C) with no condensation
Network construction for color control either within an organization or between organizations
High inter-instrument agreement between the same Konica Minolta model and also among all CM models (benchtops and portables): CM-2000 series, CM-3000 series, This inter-instrument agreement is ideal when multiple units will be used for color control either within an organization or between organizations.
CM-3700d CM-3500d
Light-receiving element Spectral separation device Wavelength range Wavelength pitch HaIf bandwidth Reflectance range Sphere size Light source Measurement time Minimum interval Between measurements Measurement/ illumination area Repeatability Inter instrument agreement Temperature dependence UV adjustment UV cut filter Transmittance chamber
R&D
Company A
Design
CM-3600d CM-3610d CM-2000 2600d series 2500d
Production
/
In-house color control
Company B
Color control between companies
Interface Power Operating temperature/ humidity range (*1) Storage temperature/ 0 to 40°C, relative humidity 80% or less (at 33°C) with no condensation humidity range Size (W x H x D) CM-3600d 244 x 208 x 378 mm, CM-3610d 300 x 597 x 315 mm Weight CM-3600d 12 kg, CM-3610d 16. 5 kg *1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series CM-3600d CM-3610d CM-3500d CM-2600d/2500d/2500c "State of the Art" Reference models Laboratory and Production Model(horizontal) Laboratory and Production Model(vertical) Unique Top Port bench-top model Top class accuracy portables
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument. [. . . ] Spectral reflectance: Within ±0. 10%/°C Color difference: Within E*ab 0. 05/°C Instantaneous numerical adjustment 400nm cutoff and 420nm cutoff Width: 133mm; depth: approx. 17mm Transmission sample holder (Optional accessory): Sample holder for both plate-shaped and liquid samples (removable) RS-232C, D-SUB 9-pin (female) terminal AC120V/230V 50/60Hz (Using included AC adapter) 13 to 33°C, relative humidity 80% or less (at 33°C) with no condensation
Network construction for color control either within an organization or between organizations
High inter-instrument agreement between the same Konica Minolta model and also among all CM models (benchtops and portables): CM-2000 series, CM-3000 series, This inter-instrument agreement is ideal when multiple units will be used for color control either within an organization or between organizations.
CM-3700d CM-3500d
Light-receiving element Spectral separation device Wavelength range Wavelength pitch HaIf bandwidth Reflectance range Sphere size Light source Measurement time Minimum interval Between measurements Measurement/ illumination area Repeatability Inter instrument agreement Temperature dependence UV adjustment UV cut filter Transmittance chamber
R&D
Company A
Design
CM-3600d CM-3610d CM-2000 2600d series 2500d
Production
/
In-house color control
Company B
Color control between companies
Interface Power Operating temperature/ humidity range (*1) Storage temperature/ 0 to 40°C, relative humidity 80% or less (at 33°C) with no condensation humidity range Size (W x H x D) CM-3600d 244 x 208 x 378 mm, CM-3610d 300 x 597 x 315 mm Weight CM-3600d 12 kg, CM-3610d 16. 5 kg *1 Operating temperature/humidity range of products for North America : 13 to 33°C, relative humidity 80% or less (at 31°C) with no condensation
KONICA MINOLTA SPECTROPHOTOMETER LINEUP
CM-3700d series CM-3600d CM-3610d CM-3500d CM-2600d/2500d/2500c "State of the Art" Reference models Laboratory and Production Model(horizontal) Laboratory and Production Model(vertical) Unique Top Port bench-top model Top class accuracy portables
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument. [. . . ]