Detailed instructions for use are in the User's Guide.
[. . . ] Spectrophotometer CM-5
Stand alone Top-Port Spectrophotometer with maximum Flexibility and Versatility
Food & Ingredients
Pharmaceuticals & Chemicals
Cosmetics & Perfumes
CM-5
offering versatile usage
CM-5 Top-Port Spectrophotometer and simple operation
Requirements for Colour measurement of Foods, Ingredients, Flavours & Fragrances, Drinks, Pharmaceuticals, Cosmetics and base Chemicals are especially demanding due to the extreme diversity of sample forms, from solids to powders, granules paste, liquid to opaque, translucent or transparent, all forms are found. [. . . ] 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c) di:0°, de:0° (diffuse illumination: 0° viewing)
Integrating sphere size Detector Spectral separation device Wavelength range Wavelength pitch Half bandwidth Measurement range Light source Measurement time Measurement/ illumination area
Ø152 mm Dual 40-element silicon photodiode arrays Planar diffraction grating 360 nm to 740 nm 10 nm Approx. 10 nm 0 to 175 % (Reflectance or transmittance); Output/display resolution: 0. 01% Pulsed Xenon lamp Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s Reflectance: Transmittance: Changeable by changing mask and settings. LAV: Ø30 mm / Ø36 mm; MAV (optional): Ø8 mm / Ø11 mm; SAV (optional): Ø3 mm / Ø6 mm Ø20 mm
Repeatability Inter-instrument agreement Transmittance chamber Display Display languages White calibration Interfaces Observer Illuminant Displayed data Color space Index
Spectral reflectance: Standard deviation within 0. 1% (400 nm to 740 nm) / Chromaticity value: Standard deviation within E*ab 0. 04 * When a white calibration plate is measured 30 times at 10-second intervals after white calibration Within E*ab 0. 15 (Typical) I (Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C) No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed 14. 5 cm TFT color LCD English, Japanese, German, French, Italian, Spanish, Simplified Chinese Automatic white calibration (reflectance) / 100% calibration (transmittance) using internal white calibration plate USB 1. 1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer) 2° Standard Observer or 10° Standard Observer A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible) Spectral values, spectral graph, colorimetric values, color-difference values, color-difference graph, pass/fail judgment, pseudo color, color assessment L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell) Reflectance: Transmittance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925); ISO Brightness, B (ASTM E 313-73) Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia
User index Color-difference equation Pass/fail judgment Storable data USB memory stick storage Power Size Weight Operating temperature/humidity range Storage temperature/humidity range
User-defined index E*ab (CIE 1976), E*94 (CIE 1994), E00 (CIE 2000), E (Hunter), CMC (l: c) Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values Sample data: 4, 000 measurements; Target color data: 1, 000 measurements Storage of measurement data and target color data. Storage/reading of measurement condition settings (Security-en-abled USB memory sticks cannot be used. ) AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter) Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm I Slide cover open: 475 (W) × 192 (H) × 261 (D) mm Approx. 5. 8 kg 13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation 0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation
< System Configuration >
Target Mask (Ø3 mm) CM-A195 Target Mask (Ø8 mm) CM-A196
Connecting Cable CM-A58
AC Adapter Dust Cover CM-A191 CM-A205 CM-A210 Transmittance CM-A206 Measurement Set · Transmittance Zero Calibration Plate CM-A213 · Transmittance Specimen Holder CM-A96 · Transmittance Specimen Holder Attachment CM-A199 · Accessory Case CM-A193 Spectrophotometer CM-5 10 mm Cell CM-A207 Measurement Set · Transmittance Specimen Holder (10 mm) CM-A198 · Transmittance Zero Calibration Plate (10 mm) CM-A204 10 mm-wide cell (Commercial product) CM-S100w Standard accessories USB Cable (2 m) IF-A19
SAFETY PRECAUTIONS
For correct use and for your safety, be sure to read the instruction manual before using the instrument. · Always connect the instrument to the specified power supply voltage. [. . . ] Konica Minolta Sensing, Inc.
Phone: 888-473-2656 (in USA), 201-236-4300 (outside USA) Phone: +31(0)30 248-1193 Phone: +49(0)89 4357 156 0 Phone: +33(0)1 493-82519 Phone: +44(0)1908 540-622 Phone: +39 02 39011. 425 Phone: +41(0)43 322-9800 Phone: +46(0)31 7099464 Phone: +43(0)1 87882-430 Phone: +48(0)71 33050-01 Phone: +34 963 30 20 13 Phone: +86-021-5489 0202 Phone: +86-010-8522 1551 Phone: +86-020-3826 4220 Phone: +65 6563-5533 Phone: +82(0)2-523-9726
Fax: +31(0)30 248-1280 Fax: +49(0)89 4357 156 99 Fax: +33(0)1 493-84771 Fax: +44(0)1908 540-629 Fax: +39 02 39011. 223 Fax: +41(0)43 322-9809 Fax: +46(0)31 474945 Fax: +43(0)1 87882-431 Fax: +48(0)71 734 52 10 Fax: +34 963 30 03 96 Fax: +86 -021-5489 0005 Fax: +86-010-8522 1241 Fax: +86-020-3826 4223 Fax: +65 6560-9721 Fax: +82(0)2-523-9729
Certificate No: YKA 0937 154 Registration Date: March 3, 1995
Certificate No: JQA-E-80027 Registration Date: March 12, 1997
©2009 KONICA MINOLTA