User manual KONICA CM-5 BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CM-5. We hope that this KONICA CM-5 user guide will be useful to you.

Lastmanuals help download the user guide KONICA CM-5.


Mode d'emploi KONICA CM-5
Download
Manual abstract: user guide KONICA CM-5BROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Spectrophotometer CM-5 Stand alone Top-Port Spectrophotometer with maximum Flexibility and Versatility Food & Ingredients Pharmaceuticals & Chemicals Cosmetics & Perfumes CM-5 offering versatile usage CM-5 Top-Port Spectrophotometer and simple operation Requirements for Colour measurement of Foods, Ingredients, Flavours & Fragrances, Drinks, Pharmaceuticals, Cosmetics and base Chemicals are especially demanding due to the extreme diversity of sample forms, from solids to powders, granules paste, liquid to opaque, translucent or transparent, all forms are found. [. . . ] 15, ISO 7724/1, ASTM E 1164, DIN 5033 Teil 7, and JIS Z 8722 (Condition c) di:0°, de:0° (diffuse illumination: 0° viewing) Integrating sphere size Detector Spectral separation device Wavelength range Wavelength pitch Half bandwidth Measurement range Light source Measurement time Measurement/ illumination area Ø152 mm Dual 40-element silicon photodiode arrays Planar diffraction grating 360 nm to 740 nm 10 nm Approx. 10 nm 0 to 175 % (Reflectance or transmittance); Output/display resolution: 0. 01% Pulsed Xenon lamp Approx. 1 s (to data display/output); Minimum measurement interval: Approx. 3 s Reflectance: Transmittance: Changeable by changing mask and settings. LAV: Ø30 mm / Ø36 mm; MAV (optional): Ø8 mm / Ø11 mm; SAV (optional): Ø3 mm / Ø6 mm Ø20 mm Repeatability Inter-instrument agreement Transmittance chamber Display Display languages White calibration Interfaces Observer Illuminant Displayed data Color space Index Spectral reflectance: Standard deviation within 0. 1% (400 nm to 740 nm) / Chromaticity value: Standard deviation within E*ab 0. 04 * When a white calibration plate is measured 30 times at 10-second intervals after white calibration Within E*ab 0. 15 (Typical) I (Based on 12 BCRA Series II color tiles compared to values measured with a master body at 23°C) No sides (unlimited sample length); Depth (maximum sample thickness): 60 mm Sample holder (optional) for holding sheet samples or containers of liquid samples can be installed/removed 14. 5 cm TFT color LCD English, Japanese, German, French, Italian, Spanish, Simplified Chinese Automatic white calibration (reflectance) / 100% calibration (transmittance) using internal white calibration plate USB 1. 1 (Connection to PC; USB memory stick); RS-232C standard (Connection to serial printer) 2° Standard Observer or 10° Standard Observer A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12, ID50, ID65 (simultaneous evaluation with two light sources possible) Spectral values, spectral graph, colorimetric values, color-difference values, color-difference graph, pass/fail judgment, pseudo color, color assessment L*a*b*, L*C*h, Hunter Lab, Yxy, XYZ, Munsell, and color differences in these spaces (except for Munsell) Reflectance: Transmittance: MI; WI (ASTM E 313-73, ASTM E 313-96); YI (ASTM E 313-73, ASTM E 313-96, ASTM D 1925); ISO Brightness, B (ASTM E 313-73) Gardner, Iodine, Hazen (APHA), European Pharmacopoeia, US Pharmacopeia User index Color-difference equation Pass/fail judgment Storable data USB memory stick storage Power Size Weight Operating temperature/humidity range Storage temperature/humidity range User-defined index E*ab (CIE 1976), E*94 (CIE 1994), E00 (CIE 2000), E (Hunter), CMC (l: c) Tolerances can be set to colorimetric values (except Munsell), color-difference values, or reflectance index values Sample data: 4, 000 measurements; Target color data: 1, 000 measurements Storage of measurement data and target color data. Storage/reading of measurement condition settings (Security-en-abled USB memory sticks cannot be used. ) AC 100 to 240 V, 50/60 Hz (using exclusive AC adapter) Slide cover closed: 385 (W) × 192 (H) × 261 (D) mm I Slide cover open: 475 (W) × 192 (H) × 261 (D) mm Approx. 5. 8 kg 13 to 33°C, relative humidity 80 % or less (at 35°C) with no condensation 0 to 40°C, relative humidity 80 % or less (at 35°C) with no condensation < System Configuration > Target Mask (Ø3 mm) CM-A195 Target Mask (Ø8 mm) CM-A196 Connecting Cable CM-A58 AC Adapter Dust Cover CM-A191 CM-A205 CM-A210 Transmittance CM-A206 Measurement Set · Transmittance Zero Calibration Plate CM-A213 · Transmittance Specimen Holder CM-A96 · Transmittance Specimen Holder Attachment CM-A199 · Accessory Case CM-A193 Spectrophotometer CM-5 10 mm Cell CM-A207 Measurement Set · Transmittance Specimen Holder (10 mm) CM-A198 · Transmittance Zero Calibration Plate (10 mm) CM-A204 10 mm-wide cell (Commercial product) CM-S100w Standard accessories USB Cable (2 m) IF-A19 SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. · Always connect the instrument to the specified power supply voltage. [. . . ] Konica Minolta Sensing, Inc. Phone: 888-473-2656 (in USA), 201-236-4300 (outside USA) Phone: +31(0)30 248-1193 Phone: +49(0)89 4357 156 0 Phone: +33(0)1 493-82519 Phone: +44(0)1908 540-622 Phone: +39 02 39011. 425 Phone: +41(0)43 322-9800 Phone: +46(0)31 7099464 Phone: +43(0)1 87882-430 Phone: +48(0)71 33050-01 Phone: +34 963 30 20 13 Phone: +86-021-5489 0202 Phone: +86-010-8522 1551 Phone: +86-020-3826 4220 Phone: +65 6563-5533 Phone: +82(0)2-523-9726 Fax: +31(0)30 248-1280 Fax: +49(0)89 4357 156 99 Fax: +33(0)1 493-84771 Fax: +44(0)1908 540-629 Fax: +39 02 39011. 223 Fax: +41(0)43 322-9809 Fax: +46(0)31 474945 Fax: +43(0)1 87882-431 Fax: +48(0)71 734 52 10 Fax: +34 963 30 03 96 Fax: +86 -021-5489 0005 Fax: +86-010-8522 1241 Fax: +86-020-3826 4223 Fax: +65 6560-9721 Fax: +82(0)2-523-9729 Certificate No: YKA 0937 154 Registration Date: March 3, 1995 Certificate No: JQA-E-80027 Registration Date: March 12, 1997 ©2009 KONICA MINOLTA www. konicaminolta. eu [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag