User manual KONICA CM-508C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CM-508C. We hope that this KONICA CM-508C user guide will be useful to you.

Lastmanuals help download the user guide KONICA CM-508C.


Mode d'emploi KONICA CM-508C
Download
Manual abstract: user guide KONICA CM-508C

Detailed instructions for use are in the User's Guide.

[. . . ] Unlike conventional spectrophotometers, correlation of the measurement results with visual evaluation of such subjects can be achieved. The ring-shaped illumination ensures stable measurement without being affected by the orientation (rotational deviation) of the instrument. [. . . ] With the CM-512m3, the E00 (CIEDE2000) equation is used with parameters fine-tuned based on proprietary knowhow to provide measurement data for metallic/pearl coatings which correlate well with visual evaluation. Measurement button Extension feet Multi-angle method (Ring illumination from three angles / Light reception in one direction) Illumination: 25º, 45º, 75º Light reception: 0º The measurement sample is illuminated from three angles and the reflection in one direction is received. Metallic/pearl colors may result in great differences in color appearance depending on the observation angle. Like visual evaluation, the multi-angle method obtains measured data by applying illumination from three different angles. Consequently, it is suitable for the evaluation of metallic/pearl colors. Applications for coating measurements Automotive exterior Even curved surfaces of car bodies or bumpers can be measured stably. The portable, handheld design ensures easy and stable measurement on production sites. The instrument can be held easily and firmly, and measurements can be taken without being concerned about its orientation (rotational deviation). (total of sample and target data) Illuminant Light source: A, C, D50, D65, F2, F6, F7, F8, F10, F11, F12 /Observer conditions Observer: 2º, 10º Temperature detection Detector: Thermopile Wavelength: 8 to 13 µm Measurement/display range: -10º to 80ºC (0. 1ºC increments) Measurement diameter: ø20 mm Measurement rating: 0º to 50ºC: ± 2. 5ºC ± 1digit (when an object of 0. 93 emissivity is measured at ambient temperatures of 18º to 28ºC) Operating temperature 0ºC to 40ºC, relative humidity 85% or less (at 35ºC) with no condensation /humidity range (*1) Storage temperature -20ºC to 45ºC, relative humidity 85% or less (at 35ºC) with no condensation /humidity range Power Four AA-size batteries or special AC adapter Size 115 (W) x 257 (H) x 164 (D) mm Weight Approx. 1. 4 kg (without batteries) *1 Operating temperature/humidity range of products for North America : 5 to 40°C, relative humidity 80% or less (at 31°C) with no condensation Worldwide (except Europe): RS-232C Cable IF-A12 (2 m) Zero Calibration Box CM-A32 Europe only: RS-232C Cable IF-A19 (2 m) White Calibration Cap CM-A87 Hand Strap CM-A24 Worldwide (except Europe): RS-232C Cable IF-A13 (5 m) Europe only: RS-232C Cable IF-A20 (5 m) Connecting Cable Hard Case CM-A64 Personal computer (commercial product) Printer (commercial product) Color Data Software CM-S100w Standard accessories Optional accessories Color Data Software CM-S100w (optional) Supports Windows® 2000/XP Outer dimensions (Unit: mm) 115 164 257 48 40 43 100 By using the Color Data Software CM-S100w (optional), you can display the data for the 3 different illumination angles simultaneously. Or, you can create a line graph that visually shows the angle characteristics specific to a multi-angle spectrophotometer. · Specifications and drawings are subject to change without prior notice. SAFETY PRECAUTIONS For correct use and for your safety, be sure to read the instruction manual before using the instrument. Always connect the instrument to the specified power supply voltage. [. . . ] Improper connection may cause a fire or electric shock. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CM-508C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CM-508C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag