User manual KONICA CS-2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual KONICA CS-2000. We hope that this KONICA CS-2000 user guide will be useful to you.

Lastmanuals help download the user guide KONICA CS-2000.


Mode d'emploi KONICA CS-2000
Download

You may also download the following manuals related to this product:

   KONICA CS-2000 BROCHURE (1571 ko)

Manual abstract: user guide KONICA CS-2000

Detailed instructions for use are in the User's Guide.

[. . . ] SPECTRORADIOMETER CS-2000 Instruction Manual Safety Symbols The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the instrument. Denotes a sentence regarding a safety warning or note. Read the sentence carefully to ensure safe and correct use. The operation must never been performed. The instruction must be strictly adhered to. [. . . ] The setting of absolute value (ABS) and difference (DIFF) is saved even after switching OFF (O). 41 MEAS UC00 T01 cd 2 m Lv x y Lv %Lv x. 0001 cd 2 m Obs SPD SYNC L E N ND BL 2° Nr m N o n S t d N o n o n Setting MEAS SNGL UC00 T01 When Using Closeup Lens Use the closeup lens in the optional accessories to measure a fine surface. For the attachment of the closeup lens, refer to the instruction manual for the closeup lens. If the closeup lens is attached, the measurement value must be compensated for the lens transmittance. This compensation coefficient is attached to the closeup lens. Use the data management software CS-S10w Professional supplied with the CS-2000 as standard to set the coefficient in this instrument. After that, when the closeup lens is selected as lens type, the measurement value compensated with the compensation coefficient can be obtained. See instruction manual of CS-S10w for details. The wrong setting of lens type leads to inaccurate measurement. Do not use the closeup lens with the ND filter. It leads to inaccurate measurement. * Lens type : STANDARD, CLOSE-UP * Factory default setting : STANDARD Setting Operation Procedure 6, 7 1 2, 3, 4, 5 1. Press MENU key when the MEAS screen is displayed. The MENU screen appears. When the backlight of the LCD has been turned off via BACKLIGHT key on the MEAS screen, the backlight is turned on. MEAS SNGL UC00 T01 cd m2 Lv x y 35. 4060 MENU Obs SPD SYNC L E N ND BL 2° Nr m I n t S t d N o n o n MEAS MEMORY TARGET OPTION SETUP 2. Press either or key to select [OPTION] and then press ENTER key. The MENU ­ OPTION screen appears. The current set contents are displayed in the [LENS] item. 42 MENU OPTION USER. CAL LENS ND-F I L T E R NON STD NON 3. Press either or key to select [LENS] and then press ENTER key. The MENU - SETUP ­ LENS (Lens type selection) screen appears. MENU OPTION LENS STANDARD CLOSE- UP 4. Press either [CLOSE-UP]. or key to select MENU OPTION LENS STANDARD CLOSE- UP When you removed the closeup lens, select [STANDARD]. 5. Press ENTER key. When the lens type is set, the MENU - OPTION screen appears again on the LCD. By pressing ESC key, after the setting is canceled the MENU - OPTION screen appears again on the LCD. Lens type setting is saved even after switching OFF (O). LENS MENU OPTION USER. CAL NON C- UP NON ND-F I L T E R 6. Press ESC key. The MENU screen appears again on the LCD. 7. Press ESC key. The MEAS screen appears again on the LCD. MEAS SNGL UC00 T01 cd m2 Lv x y 35. 4060 Obs SPD SYNC L E N ND BL 2° Nr m I n t C- U N o n o n 43 Setting When Using ND Filter Use the ND filter in the optional accessories when measuring a high-luminance object. If the ND filter is attached, the measurement value must be compensated for the filter transmittance. This compensation coefficient is attached to the ND filter. Use the data management software CS-S10w Professional supplied with the CS-2000 as standard to set the coefficient in this instrument. [. . . ] not finish in the set measurement time. 10 83 Explanation Has the closeup lens been attached? Error Symptom No. 11 Actual measurement time is different from the displayed measurement time. Item to Check Corrective Action Reference Page 12 Measurement value on the LCD disappears. 13 During USB communication: Cannot download data output from this instrument on the PC. Cannot enter commands or data from Has remote mode been the PC to this canceled?instrument. The displayed measurement time is the remaining time. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KONICA CS-2000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KONICA CS-2000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag