[. . . ] If the operator forgets to shut down the computer or radio, the battery is protected, as the Load Manager P will turn off the power before the battery is drained. 12VDC Operation: The factory pre-set voltage for shutdown is 11. 0 volts, but can be potentiometer adjusted up to 12. 85 volts. The factory pre-set shutdown time is 1 hour (when engine is not running). [. . . ] This eliminates re-booting the computer if cranking the engine drops the battery voltage below the threshold. When the device detects that the engine is not running a timer is started. After the set time has elapsed the load will be deenergized. If during the timing cycle, the battery voltage drops below its set point, the load will be immediately deenergized. Starting the engine at any time during the timing cycle will reset the timer. A block diagram appears in figure 1.
FACTORY ADJUSTED TO 1 HOUR
TIME PRE-SET ADJUST TRIMMER
TRUE IF T > T Sp AND ENGINE IS "OFF"
ENGINE OFF SENSOR
TIMER 1 HOUR TO 2 HOURS
STARTER SWITCH "ON"
TRUE WHILE ENGINE IS "CRANKING"
VOLTAGE PRE-SET ADJUST TRIMMER
POWER RELAY IF THIS LINE IS TRUE, THEN THE POWER RELAY IS ENERGIZED
VBat
VOLTAGE DETECTOR TRUE IF V < VSp Bat
Figure 1 BLOCK DIAGRAM, LOAD MANAGER P
INSTALLATION
WIRING: Figure 2 illustrates the wiring of the Load Manager P. Wire the unit using the wire gauges shown in figure 2.
#12 AWG, ORANGE
NO
RADIO & COMPUTER + LOADS
#12 AWG, RED
C
-
#12 AWG, BLACK
SIZE FUSE FOR 25% HIGHER THAN ACTUAL LOAD
1
2
3
4
FROM 12 or 24 VOLT BATTERY
#20 AWG, RED #20 AWG, BLACK FROM STARTER SWITCH (0PTIONAL)
#20 AWG, YELLOW
Figure 2 INSTALLATION WIRING, LOAD MANAGER P
ALIGNMENT: Refer to Figure 3 for all component locations and measurement points. 12VDC Operation: R102 is normally set maximum counter-clockwise for an 11. 0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. 24VDC Operation: R102 is normally set approximately 70% of full counter-clockwise for a 22. 0 volt threshold. R102 can be adjusted in a clockwise direction to obtain a higher threshold voltage. Maximum clockwise is 24. 75 volts, maximum counterclockwise is 21. 25VDC. R103 is normally set maximum counter-clockwise for a 1-hour time threshold. R103 can be adjusted in a clockwise direction to obtain a longer time threshold. [. . . ] are warranted to be free of defects of material or workmanship. Liability is limited to repairing or replacing at our factory, without charge, any material or defects that become apparent in normal use within 3 years from the date the equipment was shipped. Equipment is to be returned, shipping charges prepaid and will be returned, after repair, shipping charges paid. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-141
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.