[. . . ] FILE: 091-75 REV. B DATE: 10-19-00
INSTRUCTION MANUAL
LOAD MANAGER MARK IV
A 10 CHANNEL SEQUENCER AND LOAD SHEDDING CONTROLLER
MODEL# 091-75
INPUT: 12 VOLTS D. C.
3 YEAR WARRANTY
INTRODUCTION:
The Load Manager Mark IV is a 10-channel sequencer and load shedding controller controlling 10 external relays that are supplied by the installer. Provision has been made to permit the installer to sequence only a total of 5, 6, 7, 8, 9 or 10 channels. [. . . ] Nothing need be connected to the unused outputs. Relays must have a coil resistance of 40 ohms or greater.
1 2 3 4 5 6 7 8 9 10
S10
11 12 13
YELLOW GROUND
R EDU C E
14 15 16
CLOSE TO ENABLE LOAD MANAGER
K10
THIS LINE POWERS THE LOAD MANAGER
REV. A 10/19/00
PROGRAMMING:
Recognizing that priorities may change after an installation is made, the LOAD MANAGER MARK IV is designed so that the priority of load shedding may be easily altered.
Sequencing of the loads occurs at approximately ½ second intervals starting with the relay connected to terminal 1 and progressing to the relay connected to terminal 10.
Note that sequencing of the loads is not programmable but is controlled by the wiring connections to the LOAD MANAGER.
Ten sets of dipswitches are provided for setting the priority of load shedding. Each set of dip switches controls one output and contains 10 individual switches. Setting any one of the individual switches to the "ON" position determines the load-shed priority of that output. That is, placing the #1 switch in the "ON" position determines that this output will be the first load to shed. Placing #2 switch in the "ON" position will shed this output next. Note that any of the 10 sets of dipswitches can be set to shed first and any other to be shed next. This results in a completely random load shedding priority.
NOTE
IF THE INSTALLER DETERMINES THAT SOME LOADS SHOULD NOT BE SHED UNDER ANY CIRCUMSTANCES, THEN THE DIP SWITCH CONTROLLING THAT LOAD SHOULD BE ALL SET IN THE "OFF" POSITION.
SEQUENCE CONTROL:
The installer wiring the relays to the LOAD MANAGER MARK IV controls load sequencing. In order to limit the sequencing to fewer than 10 channels a 5element dipswitch has been provided. This switch locks out the sequencing function for channels 6, 7, 8, 9, and 10. Placing the #1 switch in the "ON" position enables channel 6 instantly, not in sequence. Placing the #2 switch in the "ON" position enables channel 7 and so forth. [. . . ] shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-75
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.