INSTRUCTION MANUAL
LOAD MANAGER 2
MODEL #091-79-12
A BATTERY VOLTAGE MONITOR WHICH DETECTS AN UNDER-VOLTAGE CONDITION AND HAS TWO OUTPUTS.
3 YEAR WARRANTY
KUSSMAUL ELECTRONICS CO. , INC.
170 CHERRY AVE. , WEST SAYVILLE, N. Y. 11796
TEL: 631-567-0314 FAX: 631-567-5826 WORLD WIDE WEB: http://www. kussmaul. com E-MAIL: sales@kussmaul. com
INTRODUCTION:
The 091-79-12 LOAD MANAGER 2 is a device which continuously monitors the voltage of the battery. [. . . ] No separate adjustment is provided for relay 2. To readjust the setpoint, remove the 4 screws and lift off the cover. Connect a variable voltage source to the battery input terminals and an ohmeter across the normally open contacts of relay 1. Vary the input voltage to the point at which relay 1 just becomes energized. Turn the trimmer resistor R100 slightly CCW to lower the setpoint or slightly CW to raise the setpoint. Check the new setting to determine what voltage will cause the relay to be energized.
CAUTION The circuit responds very slowly so allow ample time, 15 to 30 seconds for the circuit to respond to voltage changes. This time delay is required to prevent the relay from chattering for small changes in voltage around the setpoint.
SPECIFICATIONS: Input Voltage: 10 to 15 volts, D. C. Input Amps: . 020 amps, relay deenergized . 20 amps, relay energized Relay Contacts: 30 amperes, max. Case: non weatherproof, polypropylene Weight: 8 ounces
PAGE2
LOAD MANAGER OUTPUT, WILL BE DE-ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 2
LOAD MANAGER OUTPUT WILL BE DE-ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 1
N. C. N. O.
TO LOAD, WILL BE ENERGIZED WHEN VOLTAGE GOES BELOW SETPOINT OF RELAY 2
Fuse
N. C. [. . . ] shall have no liability for damages of any kind to associated equipment arising from the installation and /or use of the Kussmaul Electronics Company, Inc. The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-79
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.