[. . . ] DATE: 10-02-03 FILE: IM_091-85-XX_Rev_A INSTRUCTION MANUAL LOW VOLTAGE ALARM 1901 A LOW VOLTAGE DETECTOR WITH TIME DELAY TO MEET THE REQUIREMENTS OF NFPA 1901 MODEL(s) 091-85-12 091-85-24 091-85-24-VER 3 YEAR WARRANTY KUSSMAUL ELECTRONICS CO. , INC. 170 CHERRY AVE. , WEST SAYVILLE, N. Y. [. . . ] If the Low Voltage condition continues for more than 2 minutes the Model 091-85-XX output RELAY is energized, the GREEN LED will extinguish and the RED LED will illuminate. The output RELAY will remain energized (COM makes NO) until the sensed system voltage rises above; 12. 8VDC for Model 091-82-12 25. 6VDC for Model 091-85-24 24. 8VDC for Model 091-85-24-VER The output relay has both normally open (NO) and normally closed (NC) contacts available providing the installer with complete flexibility in wiring the alarm circuit. Any external alarm indicator or alarm horn must be provided by the installer consistent with the output relay contact ratings provided in Model specifications. The Model 091-85-XX is NOT waterproof so it is suggested that it be mounted in a suitable location. Care should be taken to wire the +VDC AND VDC Return sense lines to an electrical point representative of system voltage monitoring requirements so that an accurate indication of system voltage may be obtained. Fuse +VDC sense line as required using ONLY an ultra low resistance/voltage drop device. Refer to Figure 1 for illustration of a typical wiring configuration and output relay contact rating(s). SPECIFICATION AND OUTLINE Temperature Environment: Main Input Power: Input Current: Output Relay Rating: Model 091-85-12, -24; 0 to 50 deg C. Model 091-85-24-VER; 0 to 100 deg C Model 091-85-12; 12VDC Nominal Model 091-85-24-XX; 24VDC Nominal Model 091-85-12: 120 ma, relay ON, 50 ma relay OFF Model 091-85-24: 75 ma, relay ON, 30 ma relay OFF Model 091-85-12: 30A/240VAC/14VDC NO 20A/240VAC/14VDC NC Model 091-85-24-XX: 30A/240VAC/14VDC Model 091-85-12; 11. 8VDC Model 091-85-24; 23. 6VDC Model 091-85-24-VER: 23. 0VDC Low Voltage Alarm Threshold: Restoration Voltage Threshold: Model 091-85-12; 12. 8VDC Model 091-85-24; 25. 6VDC Model 091-85-24-VER: 24. 8VDC Low Voltage Duration for Alarm: Fixed: Two (2) minutes +/- . 5 minutes. [. . . ] The purchaser, by the acceptance of the equipment, assumes all liability for any damages which may result from its installation, use or misuse, by the purchaser, his or its employees or others. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE KUSSMAUL 091-85

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual KUSSMAUL 091-85 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag