User manual LA CROSS TECHNOLOGY IR-101TWC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSS TECHNOLOGY IR-101TWC. We hope that this LA CROSS TECHNOLOGY IR-101TWC user guide will be useful to you.

Lastmanuals help download the user guide LA CROSS TECHNOLOGY IR-101TWC.


Mode d'emploi LA CROSS TECHNOLOGY IR-101TWC
Download
Manual abstract: user guide LA CROSS TECHNOLOGY IR-101TWC

Detailed instructions for use are in the User's Guide.

[. . . ] Soft sided case Description of measuring principle When making a temperature measurement, the surface radiation of the object to be measured is evaluated using the principle of radiation thermometry. no radiation is transmitted, but instead, use is only made of the natural electromagnetic radiation energy (heat radiation) that every body above a temperature of absolute zero (-273 °C) has. The temperature can be determined very accurately from this radiation energy if the emission factor of the object being measured is known. 2. 3. 3 Operation 1. Display and operator controls All of the functions of the measuring unit are controlled and monitored using 8 the operating button (7) and the back lit display. [. . . ] A gradual warming of the unit (the lens) between ambient temperature measurements can, for example, lead to the indicated temperature slowly falling. If the emission factor for the object does not correspond to the preset value of 0. 95, the temperature will not be calculated correctly. Most surfaces have an emission factor in the range of 0. 8 to 0. 98. In general, the darker and more matte the surface is, the larger their emissions factor. If the factor is greater the 0. 95, the temperature indicated will be greater than the actual temperature of the object being measured. If the factor is less then 0. 9, the temperature indicated will be less than the surface temperature. Polished metals have a very low emission factor and are therefore not suitable for measuring with an infrared thermometer. On the other hand, affixing adhesive tape to or painting 5. 6. 5 d. f. the surface will increase the emission factor and reduce the inaccuracy of the measurement. It is not possible to take measurements through transparent materials (glass, plexiglas, etc. ). It is not possible to measure air temperatures. Measurement errors can occur due to air contaminated with dust, steam, smoke, etc. 7. TROUBLESHOOTING Problem: Display shows -. Solution: The operating button has not been pressed for long enough. This must be pressed for at least the duration of one measurement, i. e. Problem: Display shows Err 1 Solution: The ambient temperature is outside the permitted range Problem: Display shows 1 Solution: The measured value is outside the permitted range. Problem: Battery symbol illuminates Solution: The batteries are dead. NOTE: For problems not solved, please contact La Crosse Technology. Changing the batteries If the battery symbol appears in the display, the batteries must be changed. The four button cells are accessible after opening the battery compartment at the rear of the unit. The used batteries must be removed from the battery holders and replaced by new button cells of the same type. Care must be taken to ensure that the polarity is correct when inserting. The plus terminal of all four batteries should point upwards. The batteries must be checked to see that they are properly seated before closing the battery compartment. 6 2. Cleaning Clean the unit using only a dry cloth. [. . . ] La Crosse Technology, Ltd will repair or replace this product, at our option and at no charge as stipulated herein, with new or reconditioned parts or products if found to be defective during the limited warranty period specified above. All replaced parts and products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSS TECHNOLOGY IR-101TWC

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSS TECHNOLOGY IR-101TWC will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag