User manual LA CROSS TECHNOLOGY WS-7168U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSS TECHNOLOGY WS-7168U. We hope that this LA CROSS TECHNOLOGY WS-7168U user guide will be useful to you.

Lastmanuals help download the user guide LA CROSS TECHNOLOGY WS-7168U.


Mode d'emploi LA CROSS TECHNOLOGY WS-7168U
Download
Manual abstract: user guide LA CROSS TECHNOLOGY WS-7168U

Detailed instructions for use are in the User's Guide.

[. . . ] WS-7168U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents/Additional Equipment About WWVB Quick Set-Up Guide Detailed Set-Up Guide Battery installation Program Mode Program Sequence and Default Settings Function Keys Setting the LCD Contrast Setting the Time Zone Daylight Saving Time Setting Radio-controlled Time Setting 12/24-hour Time Setting Setting the Time Setting the Year, Day and Month Setting the Snooze Setting the Temperature Format Setting the Forecast Sensitivity Features Weather Forecast Icons and Tendency Arrows Indoor Temperature, Humidity, & Comfort Level Indicator Outdoor Temperatures Minimum & Maximum Records (Indoor, Outdoor, & Resetting) Additional Remote Control Sending Units (Set-Up, Viewing, & Operation) Mounting Troubleshooting Maintenance & Care Specifications Warranty Information Page 3 3 4 5 6 6 7 7-8 8 9 9 10-11 11 12 12 13 14-15 15-16 16 16-17 18-19 19-21 22-23 23 24 25-26 2 INVENTORY OF CONTENTS 1. The WS-7168U weather station (Figure 1). One TX6U remote temperature sensor (Figure 2). Mounting hardware Instruction manual and warranty card. Figure 1 Time and Date LCD Forecast LCD Indoor LCD Outdoor LCD Figure 2 Mounting Bracket TX6U temperature sensor ADDITIONAL EQUIPMENT (not included) 1. [. . . ] An arrow pointing up indicates that the air pressure is increasing and the weather is expected to improve or remain good, an arrow pointing down indicates that the air pressure is decreasing and the weather is expected to become worse or remain poor. INDOOR TEMPERATURE, HUMIDITY, AND COMFORT LEVEL INDICATOR The current indoor temperature (viewed on the left) and relative humidity (viewed on the right) are displayed in the INDOOR LCD. The comfort level indicator is located at the center of the INDOOR LCD. The indicator 15 will display a happy face icon when the temperature is between 68°F and 79°F (20°C and 25. 9°C), and the humidity is between 45% and 65%. A sad face icon will be displayed when the temperature and humidity are outside the mentioned ranges. OUTDOOR TEMPERATURE The temperature received from the remote temperature sensor is viewed in the OUTDOOR LCD. When there is more than one remote temperature sensor unit in operation, a "boxed" number will appear to the right of the temperature. This indicates which remote temperature sensor unit (1, 2, or 3) is currently displaying its data in the OUTDOOR LCD. (This feature is explained in further detail in section V--Adding Remote Temperature Sensors). MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-7168U keeps a record of the MINIMUM and MAXIMUM temperature, and the time and date of their occurrence--for both the indoor and outdoor modes. VIEWING THE INDOOR TEMPERATURE RECORDS 1. "MIN" appears above the indoor temperature and the LCD will flash, indicating that the minimum temperature (along with the humidity measured at that time) and the time and date of occurrence are displayed. The minimum records will display for 30 seconds before returning to the normal display mode. 2. Press the IN button again (once while "MIN" is still displayed, twice otherwise). "MAX" appears above the indoor temperature and the LCD will flash, indicating that the maximum temperature (along with the humidity measured at that time) and the time and date of occurrence are displayed. 16 3. While "MAX" is still displayed press the IN button again to return to the current data display. Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will automatically return to current data readings. B. VIEWING THE OUTDOOR TEMPERATURE RECORDS 1. "MIN" appears above the outdoor temperature and the LCD will flash, indicating that the minimum temperature, and the time and date of occurrence are displayed. The minimum records will display for 30 seconds before returning to the normal display mode. Press the OUT button again (once while "MIN" is still displayed, twice otherwise). "MAX" appears above the outdoor temperature and the LCD will flash, indicating that the maximum temperature and the time and date of occurrence are displayed. 2. 3. While "MAX" is still displayed press the OUT button again to return to the current data display. Or you can wait 30 seconds, during either the minimum or the maximum readings, and the unit will automatically return to current data readings. C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS 1. [. . . ] Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. La Crosse Technology, Ltd will pay all expenses for labor and materials for all repairs covered by this warranty. If necessary repairs are not covered by this warranty, or if a product is examined which is not in need or repair, you will be charged for the repairs or examination. The owner must pay any shipping charges incurred in getting your La Crosse Technology, Ltd product to a La Crosse Technology, Ltd authorized service center. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSS TECHNOLOGY WS-7168U

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSS TECHNOLOGY WS-7168U will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag