If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSS TECHNOLOGY WS9124ITCA. We hope that this LA CROSS TECHNOLOGY WS9124ITCA user guide will be useful to you.
Lastmanuals help download the user guide LA CROSS TECHNOLOGY WS9124ITCA.
Manual abstract: user guide LA CROSS TECHNOLOGY WS9124ITCA
Detailed instructions for use are in the User's Guide.
[. . . ] If these are not displayed after 60 seconds, remove the batteries and wait for at least 10 seconds before reinserting them. After inserting the battery into the sensor, the Temperature Station will start receiving data from the sensor. The outdoor temperature and the signal reception icon should then be displayed on the Temperature Station. If this does not happen after 3 minutes, the batteries will need to be removed from both units and reset from step 1. [. . . ] · Press and release to toggle between different channel readings. MIN/MAX/+ key (Min/ Max temperature) Used to toggle between the minimum and maximum recorded readings of indoor & outdoor temperature and indoor humidity. · Press and hold to reset minimum and maximum record (when min or max record is shown).
·
LCD SCREEN AND SETTINGS:
Time Indoor Temperature in °F or °C Channel No. Outdoor Temperature in °F or °C Sensor Low battery indicator
Indoor Humidity %RH Outdoor Reception Signal icon* Receiver Low * battery indicator
When the signal from the sensor is successfully received by the Temperature Station, this icon will be switched on. (If not successful, the icon will not be shown on the LCD). User can therefore easily see whether the last reception was successful ("ON" icon) or not
7
("OFF" icon). On the other hand, the short blinking of the icon shows that a reception is being done at that time. For a better display clarity, the LCD screen is split into 3 sections, showing the information of time, indoor temperature and humidity, and outdoor data. Section 1 - TIME · Display of time (manually set).
·
Section 2 - INDOOR TEMPERATURE AND HUMIDITY Display of indoor temperature and humidity.
Section 3 - OUTDOOR TEMPERATURE · Display of the outdoor temperature.
MANUAL SETTING:
12 / 24- HOUR TIME DISPLAY SETTING AND TEMPERATURE UNIT (°C/°F) SETTING User may choose to display the time in 12-hour or 24-hour mode: Note: When the time display is set as 12-hour mode, the temperature unit will be fixed to °F; when the time mode is in 24-hour format, the temperature unit will be set to °C. In normal display mode, press and hold the "SET/ CH" key for approximately 3 seconds. The "12h" or "24h" digit will be flashing. Press the "MIN/MAX/+" key to set the desired time display mode. Press and release the "SET/ CH" key to confirm and advance to the MANUAL TIME SETTING.
8
MANUAL TIME SETTING User shall manually set the time of the Temperature Station by the following steps: 1. The hour digit of the time display will be flashing. Press the "MIN/MAX/+" key to adjust the hour (press and hold to allow fast advance). Press "SET/ CH" key to confirm and go to the minute setting. Press the "MIN/MAX/+" key to adjust the minute (press and hold to allow fast advance). Press "SET/ CH" key once more to return to normal display.
VIEWING THE MINIMUM AND MAXIMUM READINGS:
User may consult the minimum and maximum recordings for indoor temperature and humidity, and outdoor temperature by following these steps: 1. Press the "MIN/MAX/+" key once to view the minimum indoor temperature and humidity and minimum outdoor temperature.
Minimum icon
2.
Press the "MIN/MAX/+" key once more to view the maximum indoor temperature and humidity and maximum outdoor temperature.
9
Maximum icon
RESETTING THE MINIMUM AND MAXIMUM READINGS:
User may reset the minimum and maximum temperature / humidity data to the current value by the following steps: 1. Press the "min/max/+" key once to display the minimum data. Press and hold the "min/max/+" key for about 3 seconds to reset all the minimum / maximum data to the current values in a single action. (Data of all outdoor and indoor data will be reset at the same time. )
TEMPERATURE SENSOR:
The outdoor temperature is measured and transmitted to the Temperature Station every 16 seconds approximately. [. . . ] You may also have other rights specific to your State. Some States do no allow the exclusion of consequential or incidental damages therefore the above exclusion of limitation may not apply to you.
16
For warranty work, technical support, or information contact: La Crosse Technology, Ltd 2809 Losey Blvd. La Crosse, WI 54601 Phone: 608. 782. 1610 Fax: 608. 796. 1020 e-mail: support@lacrossetechnology. com (warranty work) sales@lacrossetechnology. com (information on other products) web: www. lacrossetechnology. com Question?Please visit: www. lacrossetechnology. com/9124 All rights reserved. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSS TECHNOLOGY WS9124ITCA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSS TECHNOLOGY WS9124ITCA will begin.