User manual LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER. We hope that this LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER user guide will be useful to you.

Lastmanuals help download the user guide LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER.


Mode d'emploi LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER
Download
Manual abstract: user guide LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER

Detailed instructions for use are in the User's Guide.

[. . . ] BC-9009 Battery Charger Instruction Manual Contents Language Page BC-9009U BATTERY CHARGER - TABLE OF CONTENTS Topic Features Inventory Of Contents Function Keys Operating Modes Charge Mode Discharge Mode Refresh Mode Test Mode Trickle Charge Display Mode Information The Size C and D Battery Adapter Care and Maintenance Specification Warranty Information Troubleshooting Page 3 4 5 8 16 18 19 22 22 29 30 31 32 36 English 1 1 BATTERY CHARGER BC-9009U Instruction Manual INTRODUCTION: Congratulations on purchasing this intelligent charging unit which enables quick and optimum charging to "AA" and "AAA" rechargeable batteries. With charging, discharging, refreshing and capacity test functions as well as individual LCD displays for charging compartments; this charging unit is reliable, user-friendly and ideal for use in the home, office or on a journey. CAUTIONS: 1. The charger is restricted to charging NiCd and NiMH rechargeable batteries only. Never use this charger for other types of batteries such as alkaline, lithium, carbon zinc or other types that are not specified. [. . . ] Then the user may also select different discharging current (see Table 2) by pressing the CURRENT key, within 8 seconds after inserting the batteries. (The display will blink once to indicate the setting has been confirmed and the current cannot be changed afterward. ) Discharging current: 250 mA 16 mA" will be displayed. When the battery is overheated the charging will cease automatically. "000 Discharge Mode 17 displayed. Note: The discharging current is always set to be half of the coming charging current whose upper limit is 1000 mA (see Table 2). Therefore the user is recommended to carefully select the discharging current so that the charging current afterward will not be too high. The mode key shall first be pressed and held for about 1 second to activate the mode change. The subsequent pressing of the mode key will toggle between the "Charge", "Discharge", "Test" and "Refresh" mode. DISCHARGE MODE Current User-selected Discharging 100 mA current Thereafter Charging 200 mA current REFRESH MODE Old rechargeable batteries and those that have not been used for a long time require refreshing. This process will recover the optimum capacity of the rechargeable batteries. The afterward-discharging current will be half of the selected charging current (see Table 3). TEST MODE Current User-selected Charging 200 mA current Thereafter Discharging 100 mA current TRICKLE CHARGING 500 mA 250 mA 700 mA 350 mA 1000 mA 500 mA After the rechargeable battery is fully charged in any of the operating modes, the charger will give a small amount of current to the rechargeable batteries to maintain the fully charged level. This mode is automatically launched after rechargeable batteries are fully charged and kept in the charging unit. The signal "Full" will be displayed on the LCD. The maximum charging current is 1000 mA and is not affected by the number of rechargeable batteries inserted. After the test mode is finished, the display will shift between the "Full" sign and the battery capacity (in mAh or Ah) automatically in 3-second intervals until the rechargeable batteries are removed. The user can switch to other displays by pressing the DISPLAY key. Battery capacity displayed in (mAh) as the checking is finished in Test mode. DISPLAY MODE INFORMATION The user can use different display modes to monitor the rechargeable battery condition during the different operations (see below figure and Table 4 to 7). 22 23 Different display modes are exhibited: Charging current, Time, Voltage and Capacity Table 4. Various displays in Charge Mode Various displays (toggled by pressing DISPLAY key) Stage in *Time Capacity Charge mode Voltage (V) Current (mA) (hh:mm) (mAh/ Ah) During Charging charging current Instantaneous Charging time Accumulated Full stage Trickle Battery voltage elapsed capacity charging current Different operating modes 24 25 Table 5. Various displays in Discharge Mode Various displays (toggled by pressing DISPLAY key) Stage in Capacity Discharge mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) During Discharging Discharging time Capacity during discharging current elapsed discharging Instantaneous During charging Battery voltage Charging current Charging time Accumulated elapsed capacity Trickle charging Full stage current Table 6. Various displays in Refresh Mode Various displays (toggled by pressing DISPLAY key) Stage in Refresh Capacity mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) During Instantaneous Discharging Discharging time Capacity during discharging Battery voltage current elapsed discharging processes Capacity During charging Instantaneous Charging time Charging current determined in last processes Battery voltage elapsed time discharging Maximum battery Instantaneous Trickle charging Elapsed time of capacity Full stage Battery voltage current last discharging determined in discharging 26 27 Table 7. Various displays in Test Mode Various displays (toggled by pressing DISPLAY key) Stage in Test Capacity mode Voltage (V) Current (mA) *Time (hh:mm) (mAh/ Ah) Charging time During charging Charging current "--- mAh" elapsed During Discharging Discharging time "--- mAh" discharging current elapsed Capacity of the Instantaneous During 2nd 2nd charging battery Battery voltage Charging current charging time elapsed determined in discharging Capacity of the Trickle charging Discharging time battery Full stage current elapsed determined in discharging Note: *The timer will be resumed and counted from 00:00 again after the time elapsed is longer than 20 hours. (For example, 1:45 will be shown after the battery has been refreshed for 21 hr and 45 min. ) In case the power source is shortly interrupted or terminated when the charger is being operated, the operational mode will automatically be set to "Charge mode at 200 mA" to charge up the battery once the power source is back to normal, regardless the operating mode (Charge, Discharge, Refresh or Test) which has been selected by user before. 28 29 THE SIZE C AND SIZE D BATTERY ADAPTERS (FREE ACCESSORY) The battery adapters are used for connecting the AA battery to devices requiring Size C or D batteries. Install the AA battery into the Size C or Size D adapter as below. 2. [. . . ] Display--Use battery rating. . . re-chargeable never go whole way so for Voltage check for a 1. 5 you are looking at 1. 2 to 1. 4 For capacity on 2400 looking for about 1900 to 2100 (first time the capacity will be less like about 1700 to 1800). Why after I charge the battery to Full, remove, and test is not longer says Full? When you replace a charged battery it goes to trickle, and it can take from 1 to several hours to get back to a full charge depending on the condition of your battery. What is the charger capacity?If you must switch batteries in your product before they die what mode would you use to charge? --Refresh and charge. . . if you have several days --in a hurry just regular charge mode Maximum charging capacity is 3000 mAh My batteries are getting warm. It is common for batteries to get warm will charging. The charger has a built in temperature sensor which will stop the charging cycle if it has become too hot. Charging may resume 38 39 when the battery has cooled. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY BC9009 BATTERY CHARGER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag