User manual LA CROSSE TECHNOLOGY TX4-433MHZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY TX4-433MHZ. We hope that this LA CROSSE TECHNOLOGY TX4-433MHZ user guide will be useful to you.

Lastmanuals help download the user guide LA CROSSE TECHNOLOGY TX4-433MHZ.


Mode d'emploi LA CROSSE TECHNOLOGY TX4-433MHZ
Download
Manual abstract: user guide LA CROSSE TECHNOLOGY TX4-433MHZ

Detailed instructions for use are in the User's Guide.

[. . . ] Firstly, open the battery cover to your Weather Station and checking the correct polarization, insert 2 x AA, IEC LR6, 1. 5V batteries into the battery compartment. Replace the cover and ensure that the batteries do not spring free from the contacts, otherwise start up problems may occur. Slide open the battery cover of the transmitter as indicated above and insert 2 x AA, IEC LR6, 1. 5V batteries into the battery compartment and replace cover. [. . . ] 433MHZ-EMPFANGSTEST: In normal surroundings (for example, away from interfering sources such as TV sets), the outdoor temperature and humidity readings from the transmitter can usually be received within 1 minute of setting up. Should this not be the case, then check the following: The distance of all units should be at least 1. 5 ­ 2. 0 meters away from interfering sources such as computer monitors or TV sets. Avoid placing the units onto or in the immediate proximity of metal doors and window frames or structures. Using other electrical products such as wireless headphones and speakers that operate on the same frequency signal (433MHz) can prevent the transmission pick up. Neighbours using electrical items operating on the 433MHz signal can also cause interference. In most severe cases, readings will only be received once all the other electrical items using 433MHz are switched off. Within thick concrete rooms such as basements and tower blocks, the signal is naturally weaker. Should this happen, then place the Weather station closer to a window or point its front or back in the general direction of the transmitters (avoid placing near metal frames and structures). Transmission may be affected by exposure to extreme temperature conditions. For example, if the weather has been extremely cold (under -25ºC) for an extended period of time, then the 433MHz may be weakened. Please bear this in mind when positioning the transmitter (see Maintenance below). SPECIFICATIONS: · Recommended operating temperature: -29. 9ºC to +69. 9ºC with 0. 1ºC resolution · Transmission temperature update : approximately every 1 minute · Relative Humidity measuring range : 1% to 99% with 1% resolution · Transmission frequency : 433. 92 MHz · Temperature transmitting range up to: 25 meters (in open space and free from interference) · Transmission power source : 2 x AA, IEC LR6, 1. 5V batteries · Battery life: approximately 12 months (Alkaline batteries recommended) · Dimensions (L x W x H) : 60 x 73 x 121 mm Note: For full operating instructions, please refer to the main instruction manual enclosed with the Weather station. RESETTING: 1. Remove the batteries from all the transmitters and the Weather station. Wait at least 30 seconds and repeat the procedures specified in Setting up above. Always wait at least 30 seconds before reinserting the batteries, otherwise start up problems may occur. Note: Remember when inserting, the Weather station and all the transmitters have to be reset and insert the batteries into the Weather station first. LIABILITY DISCLAIMER: · The manufacturer and supplier cannot accept any responsibility for any incorrect readings and any consequences that occur should an inaccurate reading take place. · This [product is not to be used for medical purposes or for public information. · This specifications of this product may change without prior notice. · No part of this manual may be reproduce without written consent of the manuafacturer. WALL MOUNTING THERMO-HYGRO TRANSMITTER: Each transmitter is supplied with 2 wall mounting screws and plastic anchors. [. . . ] · Immediately remove all low powered batteries to avoid leakage and damage to the products. Replace only with new batteries of the recommended size. · Do not make any repairs to the unit. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY TX4-433MHZ

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY TX4-433MHZ will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag