User manual LA CROSSE TECHNOLOGY WS-7212TWC-BPX2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS-7212TWC-BPX2. We hope that this LA CROSSE TECHNOLOGY WS-7212TWC-BPX2 user guide will be useful to you.

Lastmanuals help download the user guide LA CROSSE TECHNOLOGY WS-7212TWC-BPX2.


Mode d'emploi LA CROSSE TECHNOLOGY WS-7212TWC-BPX2
Download
Manual abstract: user guide LA CROSSE TECHNOLOGY WS-7212TWC-BPX2

Detailed instructions for use are in the User's Guide.

[. . . ] WS-7212NU Wireless 433 MHz Weather Station Instruction Manual TABLE OF CONTENTS Topic Inventory of Contents Additional Equipment Quick Setup Guide Function Keys Detailed Set-up Guide Battery Installation Setting the Time Setting °C or °F Setting 12/24 Time Features Minimum and Maximum Temperatures Resetting Minimum and Maximum Temperatures Adding additional remote temp/humidity sensors (optional) Viewing & operating multiple remote temperature/humidity sensors Mounting Troubleshooting Maintenance and Care Specifications Warranty Information Page 3 4 5-9 5 10-15 10-12 12-13 13 13 14-18 14 14 15-17 17-18 18-20 20-23 24 25-26 27-29 2 INVENTORY OF CONTENTS 1. One indoor weather Figure 1 station (Figure 1) 2. The remote temperature/humidity sensor (TX4U) and mounting bracket. Instruction Manual and Warranty Card. Figure 2 3 ADDITIONAL EQUIPMENT (not included) 1. [. . . ] Press and release the "MIN/MAX" button, "MAX" appears at the bottom of the display and the recorded maximum temperatures are displayed. RESETTING THE MINIMUM AND MAXIMUM TEMPERATURES To reset both the minimum and maximum temperatures--press and hold the "MIN/MAX" button for 5 seconds. 14 C. ADDING ADDITIONAL REMOTE TEMPERATURE /HUMIDITY SENSORS (OPTIONAL) The WS-7212U is able to receive signals from 3 different remote temperature, temperature/humidity sensors. The following are some brief instructions for the basic set-up of remote sensor units with the WS7212U. These extra sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly. A TX6 will monitor temperature only, a TX3U will monitor temperature and display the temperature on its LCD, the TX3UP will monitor the temperature via a probe for use in pools, spas, etc and the TX4U will monitor temperature and humidity. 15 Note: When setting up multiple units it is important to remove the batteries from all existing units in operation, then to insert batteries first into all the remote temperature/humidity sensor units, and in numeric sequence. Second, install batteries into the indoor weather station. Transmission problems will arise if this is not done correctly and if the total time for set-up exceeds 6 minutes. It is necessary to remove the batteries from all units currently in operation. Remove the battery covers to all remote sensor units. Place all remote sensor units in a numeric sequential order. In sequential order, install batteries (follow the same battery installation procedures seen in section "I" of the Detailed Set-Up Guide) into the 16 2. Install batteries into the indoor weather stations. Follow the Detailed Set-Up Guide for programming and operating instructions. VIEWING AND OPERATING WITH MULTIPLE REMOTE SENSOR UNITS 7. To view the temperature of a different remote sensor unit, press and release the "CH" button. A shift from one "boxed" number to the next should be observed in the OUTDOOR LCD. 8. To view the Minimum/Maximum temperature: first select from which remote temperature/humidity sensor to read data from (indicated by the 17 "boxed" number). Pressing and releasing the "MIN/MAX" button will toggle through the minimum and maximum indoor temperature, and the minimum and maximum outdoor temperature. To reset the Minimum/Maximum readings, press and hold the "MIN/MAX" button for 5 seconds. MOUNTING Note: To achieve a true temperature reading, avoid mounting in direct sunlight. We recommend that you mount the remote temperature/ humidity sensor on an outside Northfacing wall. The sending range is 330 feet; obstacles such as walls, concrete, and large metal objects will reduce the range. Place both units in their desired location temporarily to test reception capability before permanently mounting. [. . . ] Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and casings. All replaced parts and products become the property of La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and products assume the remaining original warranty, or ninety (90) days, whichever is longer. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS-7212TWC-BPX2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS-7212TWC-BPX2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag