User manual LA CROSSE TECHNOLOGY WS3650

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LA CROSSE TECHNOLOGY WS3650. We hope that this LA CROSSE TECHNOLOGY WS3650 user guide will be useful to you.

Lastmanuals help download the user guide LA CROSSE TECHNOLOGY WS3650.


Mode d'emploi LA CROSSE TECHNOLOGY WS3650
Download
Manual abstract: user guide LA CROSSE TECHNOLOGY WS3650

Detailed instructions for use are in the User's Guide.

[. . . ] TOUCH SCREEN WEATHER STATION MODEL WS-3650 Operation Manual « Instant Transmission+» is the up and coming state-of-the-art new wireless transmission technology, exclusively designed and developed by LA CROSSE TECHNOLOGY. "IT +" offers you an immediate update of all your outdoor data measured from the transmitters: follow your climatic variations in real-time! 28 Table of Contents 1 . . . . . . . . . . . . . . . . . . . Important Touch Screen Operating Notes generally applicable 3 . . . . . . . . . . . . . . . . . . . Putting into Operation 3. 1 . . . . . . . . . . . . . [. . . ] Leave the mode with EXIT. Note: The wake-up alarm is activated/deactivated by twice touching the TIME section. Here the alarm symbol (((·))) will show or disappear after EXIT (or automatic timeout). 7 Weather Tendency Call up the tendency display by touching the weather symbol in the TENDENCY section. The text section (last two lines on the LCD) will show since when (with time and date) the weather condition corresponds to the presently displayed weather symbol Sunny, Fair (Cloudy with sunny intervals) or Rainy. 41 Note: · · · Up and down arrow indicate weather tendency Advanced storm warning is displayed by Rainy symbol with a flashing down arrow Every minute, when a new pressure reading is obtained, this value is compared to pressure readings from last 2 hours and the biggest resulting difference is displayed in the difference barometer. 8 Air Pressure History (Pressure History) The air pressure history shows the progress of the air pressure over a time period of 24 or 72 hours in form of a 7-step bar graph, where the length of the utmost right bar represents the present air pressure and the remaining bars show the progress of the air pressure with regard to the present air pressure. Note: The time resolution of the bar graph can be changed from fine (0 to -24 h) to coarse (0 to -72 h) and back by once touching the PRESSURE HISTORY section. 9 · · · · · · Operating and Setting of the following Functions: Air Pressure (Pressure), Relative and Absolute Indoor Temperature (Indoor Temp) Indoor Humidity (Indoor Humidity) Outdoor Temperature (Outdoor Temp), Wind Chill, Dew Point Outdoor Humidity (Outdoor Humidity) Wind Speed, Wind Gust 42 Important Note!Since operating procedures and settings are identical all steps to be carried out on the Touch Screen Weather Station for above functions shall be explained only once by means of the following example "Air Pressure". 9. 1 Air Pressure (Pressure) Example for Activating the Displays of Stored Maximum Values Call up the menu on the text section by touching the PRESSURE section. Start with MAX in the menu section. Note: Display of the stored minimum values is from here possible through MIN analog to this example. Display of stored value. Proceed with MAX PRESSURE. Resetting of the displayed value to the present value with CONFIRM. Without resetting advance with EXIT. End of Example Example for Setting of Alarms by means of the HI Alarms As in the example above here too call up the menu on the text section by touching the PRESSURE section. Start with ALARM in the menu section. 43 Proceed with HI AL in the menu section. Note: Setting of the LO alarms is from here possible through LO AL analog to this example. Setting of high alarm value with UP or DOWN. Proceed with ON/OFF. Activate or deactivate the alarm with ON or OFF. Note: Activation or deactivation of the alarm (Display or deletion of the (((·))) symbol) only pertains to the respective presently displayed value. End of Example Note: Twice touching the PRESSURE section toggles the displays of the Relative (rel) and Absolute (abs) air pressure. All setting and display facilities only pertain to the respective presently displayed value. 10 Operating and Setting of Function Rain Note: Besides the direct setting of the units for the rain amount in the basic setup procedure there is the possibility to toggle between the following displays by twice touching the left part of the RAIN section: 44 · Rain amount of the last hour · Rain amount of the last 24 hours · Rain amount of the last week · Rain amount of the last month Note: The rain amounts of the last week and of the last month do not represent the amounts collected up to the present point of time but those of the last complete week or the last complete month respectively. All setting and display facilities only pertain to the respective presently displayed value. Operation and settings of the function Rain are essentially corresponding to the ones described in Item 9 above. Therefore a short description of the trivial differences with regard to Item 9 should be sufficient. · Since in the display function Rain the display of minimum rain values is unnecessary, the menu does not offer the item MIN but MAX only to display the various maximum rain amounts. · Since because of the above no minimum alarms are necessary the menu will upon activating ALARM avoid Hi AL resp. LO AL selection and immediately proceed to the HI alarm setting as already described in Item 9 above. Note: The setting facility for the alarms is only offered during display of the rain amounts of the last hour resp. [. . . ] Injuries, burns, or property damage may be resulted if the batteries are in contact with conducting materials, heat, corrosive materials or explosives. The batteries shall be taken out from the unit before the product is to be stored for a long period of time. Immediately remove all low powered batteries to avoid leakage and damage. Replace only with new batteries of the recommended type. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LA CROSSE TECHNOLOGY WS3650

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LA CROSSE TECHNOLOGY WS3650 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag