Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LEGRAND 845 57. We hope that this LEGRAND 845 57 user guide will be useful to you.
Lastmanuals help download the user guide LEGRAND 845 57.
Detailed instructions for use are in the User's Guide.
[. . . ] In addition if a sequence of more than 16 incorrect key presses in entered the keypad will be disabled for the next 15s. The Keypad's User Access Code is independant from any access codes used with Control Panel based systems. Note: If used within a multi-user system such as the SA5, the keypad will register in the event log as "User 6" The Keypad is powered by a 9V PP3 Alkaline battery. [. . . ] When the battery level falls below an acceptable level, the "LOW BATT" indicator on the front of the Keypad will flash. When this occurs the batteries should be replaced as soon as possible.
Positioning the Remote Keypad
The Keypad is suitable for mounting in dry interior locations only. The Keypad should be located within a protected area, so that an intruder cannot reach the Keypad without first activating a PIR or magnetic door contact detector. The Keypad should be mounted in a position close to the main entrance door so that the user access code can be entered and the alarm system shut down within the 15s entry time period. Ensure that the position selected for the Keypad is within effective range of the Siren, (refer to "System Installation and Operating Manual"). Note: DO NOT fix the Keypad to metalwork or locate the unit within 1m of metalwork (i. e. radiators, water pipes, etc) as this could affect the radio range of the Keypad. Important: If used with a "Siren Controlled" alarm system (i. e. a system without a separate Control Panel), jumper link P1 located in the top left corner of the PCB must be removed; or If the Keypad is to be used with a Control Panel based system, jumper link P1 must be left in place. The siren will
beep/flash twice and then after approx 10s the siren emits a single long beep (and LEDS flash three times). The Disarm key may now be released.
1. Ensure that the Control Panel is in Test/Programming Mode, or that the Siren is in Service Mode for single zone systems without a Control Panel, (refer to "System Installation and Operating Manual"). Undo fixing screw at bottom of Keypad and remove from wall mounting plate. Undo four fixing screws in the rear cover and remove cover. Replace battery with a new 9V PP3 Alkaline battery. Replace and fix the rear cover and then refit and secure the Keypad onto the wall bracket. Remember to return the Siren to Operating Mode and/or the system to Standby Mode as appropriate. Note: The Keypad will retain the User Access code for approximately 15 seconds whilst the battery is removed to be replaced. [. . . ] If the battery is disconnected for longer or has been allowed to run completely flat the User Access code will revert to the factory default (1234) when the new battery is connected. The User Access code will then need reprogramming to your own setting.
Siren Operating Mode:
To switch the Siren into Operating Mode: Single Zone system Press (hold) for approx 10s ??, until the siren emits a single long beep (and LEDS flash three times). [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LEGRAND 845 57
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LEGRAND 845 57 will begin.