Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LEICA EG 1150 H. We hope that this LEICA EG 1150 H user guide will be useful to you.
Lastmanuals help download the user guide LEICA EG 1150 H.
Detailed instructions for use are in the User's Guide.
[. . . ] Leica EG1150 H
Paraffin Embedding Station
Instruction Manual Leica EG1150 H V2. 2 English, Rev. B - 12/2009 Always keep this manual near the instrument. Read carefully prior to operating the instrument.
IMPORTANT NOTE The information, numerical data, notes and value judgments contained in this manual represent the current state of scientific knowledge and state-of-the-art technology as we understand it following thorough investigation in this field. We are under no obligation to update the present manual periodically and on an ongoing basis according to the latest technical developments, nor to provide our customers with additional copies, updates etc. [. . . ] Operation
Paraffin collection tray (8) Two indirectly-heated paraffin collection trays for excess paraffin are located under the work surface.
7 6
8 8
The paraffin collection tray must be emptied daily. To prevent contamination, do not reuse paraffin collected in this tray. If the instrument is operated without the paraffin collection trays there is risk of burning.
17 16
Mold warmer and cassette warmer (16) Depending on the preferred working direction, the two heated trays can be used for molds or cassettes (6, 7). The temperature is adjustable between 55 °C and 70 °C. A removable receptacle (16) can be placed in each of the trays. A lid (17) is provided for each of the trays (16) to prevent loss of heat and contamination inside the tray. For easy access, the lid can be opened and folded back.
Fig. 11
When working with half-open lids (17), raise the temperature one level to ensure that the paraffin remains molten.
Only operate the cassette and mold warmer and paraffin reservoir with lid; otherwise the set temperature cannot be maintained.
20
Instruction Manual V 2. 2, Rev B 12/2009
5. Operation
21 8
Standby switch (8) After the unit has been commissioned, the standby switch should only be used if the unit is to be switched off for a longer period of time. In daily routine operation, the ON/OFF button on the control panel should be used. Pressing the ON/OFF button (20) switches the instrument into active standby mode. All displays are switched off, only the LED (21) of the ON/OFF button remains lit.
If programmed procedures are to be carried out: the standby switch (8) must be switched on and the unit must be in standby mode. For more information, see Chapter 5. 4.
9
20
18
19
Fig. 12
Work area illumination (9) A halogen lamp provides homogeneous diffuse illumination of the embedding area and refrigeration spot. This gives an optimum view of the embedding process and tissue orientation. The lamp should be adjusted in a way that it is switched on and off only with the lamp button on the control panel. For this purpose, turn the cap (18) in the position where the two "I" "I" marks (19) are located one above the other. To access the halogen bulb, the cap (18) can be removed. (For replacement of the halogen lamp see Chapter 7. 2)
Leica EG1150H Paraffin Embedding Station
21
5.
Operation
Foot switch (22) optional
22
The foot switch (22) actuates the magnet valve of the dispenser. It must be connected as described in Chapter 4. 6.
The plug of the foot switch MUST be screwed onto the socket. Otherwise hot paraffin may escape even when the foot switched is not being pressed.
11
14 12
Pressing the foot switch opens the valve, releasing it closes it. This keeps the operator's hands free to work with the instrument. [. . . ] 23
Leica EG1150 H Paraffin Embedding Station
35
7.
Troubleshooting
7. 3 Changing a fuse
Before changing a fuse switch the instrument off and pull out the mains plug. Use ONLY the provided replacement fuses. The instrument has a number of circuits that are protected by fuses with different values. Observe the following instructions exactly to ensure that the correct spare fuse is used for the matching fuse holder.
The instrument has five electrical areas with separate secondary fuse protection. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LEICA EG 1150 H
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LEICA EG 1150 H will begin.