User manual LEICA IMS500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LEICA IMS500. We hope that this LEICA IMS500 user guide will be useful to you.

Lastmanuals help download the user guide LEICA IMS500.


Mode d'emploi LEICA IMS500
Download
Manual abstract: user guide LEICA IMS500

Detailed instructions for use are in the User's Guide.

[. . . ] The "Safety concept" booklet contains additional safety information regarding the service work, requirements and the handling of microscope, accessories and electrical accessories as well as general safety instructions. Symbols used in this operating manual Warning of a danger This symbol indicates especially important information that must be read and complied with. Important information This symbol indicates additional information or explanations that intend to provide clarity. · Failure to comply can cause the following: Hazards to personnel Functional disturbances or damaged instruments Explanatory notes This symbol within the text points to additional information and explanations. Warning of hazardous electrical voltage This symbol indicates especially important information that is mandatory to read and observe. Failure to comply can cause the following: Hazards to personnel Functional disturbances or damaged instruments Danger due to hot surface. This symbol warns against touching accessible hot surfaces, e. g. those of light bulbs. Leica IMS500 / IMS500 HD Manual 4 Important Notes Description The Leica IMS500 Systems meets today's state of the art of technology. [. . . ] After service work or technical modifications, the unit must be reconfigured with observance to our technical requirements. If the unit is modified or serviced by unauthorized persons, is improperly maintained (as long as maintenance was not carried out by us), or is handled improperly, Leica will not accept any liability. The electric installation in the building must conform to the national standard, e. g. current-operated ground leakage protection (fault-current protection) is suggested. Ensure that this user manual is always available. Carry out regular inspections to make certain that the authorized users are adhering to safety requirements. When instructing new users, do so thoroughly and explain the meanings of the warning signs and messages. Assign individual responsibilities for starting, operating and servicing the instrument and monitor the observance of these responsibilities. Do not use the Leica IMS500 Systems system unless it is in perfect condition. Leica IMS500 / IMS500 HD Manual 7 Care instructions General instructions Protect the Leica IMS500 Systems against damp, vapors, acids, alkalis, and corrosive substances. Protect the Leica IMS500 Systems from oil and grease. Never use chemicals to clean colored surfaces or accessories with rubberized parts. This could damage the surfaces, and specimens could be contaminated by abraded particles. It is advisable to enter a service agreement with Leica Service. Cleaning coated parts and plastic parts Dust and dirt particles should be removed with a soft brush or lint-free cotton cloth. Remove coarse debris with a moistened disposable cloth. Clinging dirt can be removed using petroleum ether or alcohol. Acetone, xylene or nitro-containing thinners must NOT be used. Leica IMS500 / IMS500 HD Manual 8 Accessories, maintenance and repair Accessories Only the following accessories may be used with the Leica IMS500 Systems: The Leica accessories described in this user manual. Other accessories, provided that these have been expressly approved by Leica as being technically safe in this context. Maintenance The Leica IMS500 Systems are basically maintenancefree. To ensure that it always operates safely and reliably, we recommend that you take the precaution of contacting the responsible service organization. Repairs and service work Only original Leica Microsystems spare parts may be used. Before opening the instruments, switch off the power and unplug the power cable. Avoid contact with powered electrical circuits, which can lead to injury. them. appropriate, conclude a maintenance contract with You can arrange for periodic inspections or, if It is advisable to enter a service agreement with Leica Service. For maintenance and repair, only OEM spare parts may be used. Service address In case of problems, please contact us as follows: Leica Microsystems (Switzerland) Ltd. Industry Division Max Schmidheiny Strasse 201 CH-9435 Heerbrugg (Switzerland) Phone +41 71 726 33 28 Leica IMS500 / IMS500 HD Manual 9 Electrical data and ambient conditions Electrical data See specifications page Environment Temperature for use Storage temperature Manipulation shock Transport shock (unpacked) Transport shock (packed) Transport vibrations (unpacked Atmospheric pressure "in use" and for storage: Humidity "in use" and for storage: Installation Category II (Overvoltage Category) Pollution degree 2 Unpacking Carefully remove the system and any components from the packing carton. Check the components against the planned configuration. Optional items such as camera adapters, cameras, and carrying cases are not shipped as part of the standard equipment. These items are delivered in separate packages. Please do not discard any of the packing materials. They should be used for safely storing and transporting the instrument should the need arise. +10 °C . . . The next keys selected become the receivers. [. . . ] A students´screen must first be transmitted to the instructor. + + + Remote control of all student computers (PS/2 system only) To control all student´s keyboards and mouses hold down the ALT FUNCT key while pressing the REMOTE key. Leica IMS 500 Manual 18 Keypad Dimensions* (W-H-D) Weight Power Communication Specifications IMS500 Type KP15 Type KP25 12. 5 x 4 x 17cm 15 x 4 x 21 cm ca. 550 g 5VDC and 10VDC supplied by Central Unit Serial 4Wire RS-232 Protocol Type KP35 19. 5 x 4. 5 x 22 cm ca. 800 g * Dimensions of keyboard only (no cables/plugs). Central Unit Dimensions* (W-H-D) Weight Power Consumption CU15 24 x 15 x 28 cm max. 300 W * Dimensions of rack only (no cables/plugs Modules Dimensions* (W-H-D) Weight Power Imaging Module 11. 5 x 3. 2 x 9 cm (no cables connected) 175 g +10VDC and -10VDC supplied by Central Unit Computer Control Module * Dimensions of box only (no cables/plugs). [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LEICA IMS500

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LEICA IMS500 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag