Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LEITZ PRADOVIT-F. We hope that this LEITZ PRADOVIT-F user guide will be useful to you.
Lastmanuals help download the user guide LEITZ PRADOVIT-F.
Detailed instructions for use are in the User's Guide.
[. . . ] which the cooling
so the remote
set to the center fan is still projector. pressed completely.
of the focusing the button off
left on for a quicker Operating down, switches
of the is still
projector
5
10432-31
Remote control with moving and forward at will.
the magazine
backward
Operating
moving
the slide changer
the magazine at will.
of the projector
and
1. The slide changing is operated by a short depressing of the button. "] Depressing the white button for a short time only should specially be observed for shifting the 1st slide into the film gate. Drepressing the red button operates the remote control for focusing. [. . . ] turning of the arrow the the milled
by hand alter
transport changer button manu-
magazine knob
in the direction
moves the slide
9
The motor and gears need no maintenance, be oiled.
of
and
the pradovit must never
Maintenance
Opening
the Lamp House.
Disconnect the projector before opening the lamp house!The lamp house cover will swing open when you gently lift the spring catch inside the magazine chamber. To close, push down the lamp house cover from the outside until the spring catch engages again.
10
. , ~.
. .
10433·31
Taking
off the side panel.
Inserting
and changing
the projection
lamp.
The side panel which carries the name "prodovit" can be pulled upwards after first maving the twa holding springs ta the side. Before doing so, the screw which holds the springs, must be slightly losened and depressed.
First lift out the lamp chimney. The prajection lomp 300 or 500 watt with pin-type-cap G 17 q far pradovit-f is pushed in firmly. The pins in the cap of the lamp must be guided exactly into the cutouts of the socket. To change the lamp pull upwords without turning it. The low voltage lamp 12 V/100 watt for the pradovit-n has twa guide pins at the lamp cap. Push the low voltage lamp in the cutouts af the lamp socket and turn it to the right until both pins engage in the bayonet fitting. When taking out the lamp, push it down first and turn to the left to disengage the bayonet fitting.
11
10430-31
Centering the Projection Lamp. For centering pinhole a white obtained shown slide piece of the reflected jection-lens. in front centering is observed 'can insert the The above the ideal double the low reflected illustration focusing image voltage image of the image represents With the to the obove With it is aimed into the film image of po per the The filament by holding of the proeasily screw be as for the pradovit-f. field for
of the filament lamp
get as a homogeneous
os possible. the pradovit-n
The best position by turning
must be seen exactly
in the illustrotion.
the lamp filoment.
12
Cleaning. words are projection All coated opening the of For (not the lamp house you with can easily as the heat prosable the the other lenses, This withdraw holder the lamp aspheric the chimney condenser, especially only a soft, cloth). unscrew and the reflector and of the clean it from in layer. appreciably increases trast of the projected LEITZ stands faces are dirt. still hard coating up to normal as any sensitive the brilliance and conimage. Although the is highly resistant the glass optical marks Remove with of course, and any and surother major fluffcleaning,
as well
movable use
condenser
cleaning,
high-quality to finger
glass
lens,
an antistatic lens simply exposed with lens
To clean
So avoid
touching
any glass
and mirror a soft,
surface
with your fingers. immediately should, which
surfaces, projection
contamination less cloth lutely clean.
the condensers
be abso-
an antireflection
13
Accessories and Other Data
Positioning the Condenser for 24 x 36 mm or l'h x l'h inch (38 x 38 mm) Transparencies
The holder for the movable condenser and heat filter can be inserted in two ways: For optimum illumination on 24x36 mm miniature transparencies place it in position 1 for 11/2 x 11/, inch (38x 38 mm) super-slides place it in position 2. [. . . ] to 50 or 60 cycles, Pertinaxplate The rectanguthe required the corPertinaxplate
+
other
as for
50 cycles,
To set the frequencey holding is then of the transformer plate number of frequency voltage.
the rectangular are losened. shifted so that stands
opposite
responding
16
Projection
Lamps.
intervals takes with projection prefocus with filter lamps G 17 q pin of 300 type a lamp voltage. voltage, a 230 volt
above If your lamp
and AC
below supply
the normal carries
supply
The pradovit-f and cap. disk 500 watt
an overone, or that the
then you should in place even new a cases
choose, a lamp lamp,
for instance, for 240 volts. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LEITZ PRADOVIT-F
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LEITZ PRADOVIT-F will begin.