User manual LG 25862

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG 25862. We hope that this LG 25862 user guide will be useful to you.

Lastmanuals help download the user guide LG 25862.


Mode d'emploi LG 25862
Download
Manual abstract: user guide LG 25862

Detailed instructions for use are in the User's Guide.

[. . . ] CONSTRUCTION VIEWS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SPECIFICATIONS OF ELECTRICAL PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . REFRIGERANT CYCLE DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] Mark the corresponding pipe hole wall positions according to the positioning marks ( ð ) on the installation plate. Drill the pipe holes (Ø65 mm) slightly slanted downward to the outside. Remote controller · Should be placed where there are no obstacles, such as curtains, that may block the signal. · Do not install the remote controller in a place exposed to direct sunlight or close to a heating source, such as a stove. · Keep the remote controller at least 1 m away from the nearest TV set or stereo equipment. (This is necessary to prevent image disturbances or noise interference. ) · The location of the remote controller should be determined as shown below. Indoor unit NOTE : · When drilling into a wall that contains a metal lath, wire lath or metal plate, be sure to use a pipe hole brim ring sold separately. Mounting the installation plate Anchor bolt holes (Side view) (Top view) Indoor unit 25 mm 91 mm Pipe hole Reception range Remote controller Reception range Remote controller Pipe hole Indoor unit 6 Mounting screw 1 Installation plate *: Axial distance Fig. 10-3-3 ­ 60 ­ When the installation plate is directly mounted on the wall 1. Securely fit the installation plate onto the wall by screws with the upper and lower catches. To mount the installation plate on a concrete wall use anchor bolts. Drill the anchor bolt holes as illustrated in the above figure. Place the level at the top end of the installation plate, and check that the plate is horizontal. 10-3-3. The supply voltage must be the same as the rated voltage of the air conditioner. 10-3-7 Connecting cable How to remove the drain cap Clip drain cap with needle-nose pliers, and pull out. About 15 cm Fig. 10-3-11 110mm 10mm Earth line How to remove the drain hose The drain hose is secured in place by a screw. Remove the screw securing the drain hose, then pull out the drain hose. 10mm 50mm Fig. 10-3-9 NOTE : · Connecting cable (Indoor unit/outdoor unit) · Wire type: H07RN-F or 60245IEC66 (1. 0 mm²) Screw Fig. 10-3-12 ­ 62 ­ Die-cutting Front panel slit Cord clamp Bottom left Drain hose Changing drain hose Rear left Piping preparation How to attach the drain cap 1. Insert hexagonal wrench (4 mm). In case of bottom right or bottom left piping · After making slits on the front panel with a knife or similar tool, cut them out with a pair of nippers or an equivalent tool. Slit 4 mm Fig. 10-3-13 Left-hand connection with piping 2. Bend the connecting pipes so that they are positioned within 43 mm above the wall surface. If the connecting pipes are positioned more than 43 mm above the wall surface, the indoor unit may be unstable. When bending the connecting pipe, make sure to use a spring bender to avoid crushing the pipe. No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. If applied, deterioration and drain leakage of the drain plug may occur. Insert a hexagon wrench (Ø4mm) Refer to the table below for the bending radius of each connection pipe. Outer diameter 6. 35 mm Bending radius 30 mm 40 mm 50 mm Fig. [. . . ] 8) Move the thermal constringent tubes toward the soldered parts and heat them with the dryer and constring them. 9) Wind the attached color tape round the both terminals of the protective tube when colored protective tube is used. 10) Fix the sensor again. Remarks Cutting here Connector 100 Thermal sensor part 200 Cutting here 15 70 Thermal constringent tube Cutting here 100 15 70 Soldered part Dryer Winding the color tape NOTE 1) Store the joint part of the sensor and the connector in the electric parts box. 2) Never joint them near the thermal sensor part. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG 25862

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG 25862 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag