[. . . ] 10
EN
1
Engineering Data
1
1-1.
Model
Specifications
Indoor Unit (Concealed Duct High Static Pressure Type)
Indoor unit Outdoor unit
(kW) (kW) Power supply Indoor unit Running current Power consumption Power factor Power supply Cooling Outdoor unit Running current Power consumption Power factor Power consumption Total EER Energy efficiency class * Power supply Indoor unit Running current Power consumption Power factor Power supply Heating Outdoor unit Running current Power consumption Power factor Power consumption Total Indoor unit Outdoor unit Main unit Main unit Height Width Depth Main unit Fan Standard air flow at 137Pa/ (at Mid tap) (m3/h) (W) (Pa) (mm) (mm) (mm) (kg) COP Energy efficiency class * Maximum current (A) (A) (V) (A) (kW) (%) (V) (A) (kW) (%) (kW) (V) (A) (kW) (%) (V) (A) (kW) (%) (kW)
RAV-SM2242DT-E
20. 0 (9. 8-22. 4) 22. 4 (9. 8-25. 0) 5. 25-4. 81 1. 12 97 9. 83-9. 00 6. 08 94 7. 20 (3. 26-9. 09) 2. 78 D 5. 25-4. 81 1. 12 97 8. 68-7. 95 5. 37 94 6. 49 (2. 57-7. 45) 3. 45 B 15. 0 18. 0 470 1380 1250 160
66612
23. 0 (9. 8-27. 0) 27. 0 (9. 8-31. 5) 5. 25-4. 81 1. 12 97 12. 33-11. 29 7. 63 94 8. 75 (3. 36-12. 76) 2. 63 D 5. 25-4. 81 1. 12 97 11. 36-10. 40 7. 03 94 8. 15 (2. 57-11. 01) 3. 31 C 15. 0 20. 0 470 1380 1250 160
RAV-SM2244AT8-E RAV-SM2804AT8-E
Cooling capacity (min. -max. ) Heating capacity (min. -max. )
50Hz / 1ph / 220-240V
50Hz / 3N~ / 380-415V
Electrical characteristics
50Hz / 1ph / 220-240V
50Hz / 3N~ / 380-415V
Appearance Outer dimension Total weight Heat exchanger
Zinc hot dipping steel plate
Finned tube Centrifugal fan 3600 1 370×3 196/137/68. 6 None (Local procure) H/M/L H/M/L Gas side Liquid side Drain port (dB·A) (dB·A) (mm) (mm) (mm) 54 74 28. 6 12. 7 32 (VP25) Centrifugal fan 4200 1 370×3 196/137/68. 6 None (Local procure) 55 75 28. 6 12. 7
Fan unit
Fan Speed Motor External static pressure (H/M/L)
Air filter Controller (Sold Separately) Sound pressure level Sound power level Connecting pipe
RBC-AMT32E, AS21E2
2
EN
Engineering Data
2
Dimension
(Unit:mm)
Space required for installation and serving
RAV-SM2242DT-E, 66612 / RAV-SM2242DT-TR, RAV-SM2802DT-TR
200
Service space
1260 (Hanging bolt mounting pitch) 1288 (Hanging bolt mounting pitch) 1328 1250
or more
600
200
1000 or more
Check port
Service space
Hole for hanging bolt
(4-12 × 92)
250 35
250
250
250
190
*
Refrigerant pipe connecting port (Gas side Brazed)
*
Electric parts box Power supply/communication piping port (Ø26) (Under electric parts box)
Refrigerant pipe connecting port (Liquid side Ø12. 7 Flared)
370
150
65
31
22
Drain pipe connecting port (V25)
Screw hole for duct mounting (10-M6)
46 Taper screw for R1, 25. 4 pipes 65
624 698
29
190
250
250
250
250
*
Diameter of pipe connecting port Liquid side Gas side Ø12. 7 Ø22. 2
Diameter of connecting pipe Liquid side Gas side Ø12. 7 Ø28. 6
406
The diameter of connecting gas side on the indoor unit is 22. 2, and therefore please use the accessory joint for installation. [. . . ] Be sure to set a check port at the right of air discharge port. Set to slope the drain piping downward at 1/100 and be sure to set a drain trap on its way as shown below figure. Please avoid the installation on the place where oil disperses or is shrouded by oil smoke, such as kitchen or mechanical factory. Indoor unit does not have air filter its inside. A dotted line and broken line indicate the wiring at site. When installing the drain pump connect the froat switch connector to CN030 connector. A position is connected to terminal block when change to static pressure. Exchange the lead wire of arrow ( position after check the terminal number as figure and lead wire's color of fan motor.
)
4
EN
Engineering Data
4
Refrigerating Cycle Diagram
RAV-SM2242DT-E(TR), SM2802DT-E(TR)
Distributor (Strainer incorporated)
Indoor unit
TCJ sensor Air heat exchanger
TC sensor
Refrigerant pipe at liquid side ØB
Refrigerant pipe at gas side ØA
To outdoor unit
Heating Cooling
To outdoor unit
Dimension table
Indoor unit SM224, SM280 type Outer diameter of refrigerant pipe Gas side ØA
28. 6
Liquid side ØB
12. 7
EN
5
Engineering Data
5
Sensible Capacity Table
Duct High Static Pressure Type Sensible Heat Capacity : RAV-SM2242DT-E(TR) / 66612(TR)
indoor air temp. [. . . ] Exchange the lead wire of arrow ( position after check the terminal number as figure and lead wire's color of fan motor.
)
4
EN
Engineering Data
4
Refrigerating Cycle Diagram
RAV-SM2242DT-E(TR), SM2802DT-E(TR)
Distributor (Strainer incorporated)
Indoor unit
TCJ sensor Air heat exchanger
TC sensor
Refrigerant pipe at liquid side ØB
Refrigerant pipe at gas side ØA
To outdoor unit
Heating Cooling
To outdoor unit
Dimension table
Indoor unit SM224, SM280 type Outer diameter of refrigerant pipe Gas side ØA
28. 6
Liquid side ØB
12. 7
EN
5
Engineering Data
5
Sensible Capacity Table
Duct High Static Pressure Type Sensible Heat Capacity : RAV-SM2242DT-E(TR) / 66612(TR)
indoor air temp. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG 66612
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.