[. . . ] PART REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy) 11-2 Indoor Unit 11-3 Outdoor Unit
-1-
FILE NO. SPECIFICATIONS
MODEL ITEM Capacity Power source Power consumption Power factor Running Indoor Current Outdoor Starting current Moisture removal Noise Indoor (H/M+/M/L+/L) Outdoor (220-240V) Refrigerant Name of refrigerant Rated amount Refrigerant control Interconnection Gas side size pipe Connection type Liquid side size Connection type Maximum length (One way) Maximum height difference INDOOR UNIT Dimensions Height Width Depth Net weight Evaporator type Indoor fan type Airflow volume High fan Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Dimensions Height Width Depth Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Model Output Safety device Louver type Usable outdoor temperature range kW Phase V Hz kW % A A A lit/h dB dB kg mm mm m m mm mm mm kg 220V 3. 73 75286 / RAS-13S2AH-ES2 Cooling 240V 3. 78 1 220 - 240 50 1. 14 96 5. 25 1. 19 88 0. 15 5. 65 5. 25 22 2. 0 41/38/35/33/31 51 50 R410A 1. 05 Capillary tube 12. 7 Flare connection 6. 35 Flare connection 15*1 6 75286 275 790 205 9 Finned tube Cross flow fan 600 430 380 20 Filter (RB-A620DE) RAS-13S2AH-ES2 550 780 290 34 Finned tube Propeller fan 2200 2120 42 PA145G1C-4FT1 1100 Fuse, Overload relay Automatic louver 15 ~ 43 -10 ~24 620 520 400 5. 60 1. 14 96 1. 18 86 220V 4. 15 Heating 240V 4. 25
50
51
m3/h m3/h m3/h W
mm mm mm kg
m3/h W W
2120
2200
°C
-2-
FILE NO. SVM-10026
Note : 1 · Capacity is based on the following temperature conditions. [. . . ] (Use polyethylene foam as insulating material. ) Rear right
4 mm
How to fix the drains cap 1) Insert hexagonal wrench (4 mm) in a center head.
Left Bottom right Right
Die-cutting Front panel slit
Bottom left
Changing drain hose
Rear left
Piping preparation
Fig. 8-4-10 2) Firmly insert drains cap.
No gap Do not apply lubricating oil (refrigerant machine oil) when inserting the drain cap. Application causes deterioration and drain leakage of the plug. Die-cutting Front panel slit Cut out the slit on the leftward or right side of the front panel for the left or right connection and the slit on the bottom left or right side of the front panel for the bottom left or right connection with a pair of nippers. Changing drain hose For leftward connection, bottom leftward connection and rear leftward connection's piping, it is necessary to change the drain hose and drain cap.
Fig. 8-4-11
CAUTION
Firmly insert the drain hose and drain cap; otherwise, water may leak. <In case of right or left piping> · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool.
How to remove the drains cap Clip drain cap by needle-nose plier, and pull out.
Fig. 8-4-8 How to install the drain hose · The drain hose can be removed by take off screw, after that twisting and pulling. · When removing the drain hose, be careful of any sharp edges of steel plate. The edges can cause injuries.
Heat insulator
Slit
Fig. 8-4-12 <In case of bottom right or bottom left piping> · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool.
Slit
Drain hose
Fig. · A place free of a leakage of combustible gases. · A place which does not block a passage. · When the outdoor unit is to be installed in an elevated position, be sure to secure its feet. · An allowable length of the connecting pipe is up to 15m · An allowable height level is up to 6m. · A place where the drain water does not raise any problem.
50 mm or more
Do not put the drain hose end into water.
Do not put the drain hose end in the drainage ditch.
Fig. Put water in the drain pan and make sure that the water is drained out of doors. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe.
Shield pipe
CAUTION
1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. Installation in the following places may result in trouble. [. . . ] 2) Remove the pipe holder from the rear side of the main unit. 3) Remove two fixing screws at the left side of the end plate of the heat exchanger.
2 screws
4) Remove one fixing screw on the heat exchage fixing holder to separate the heat exchage from the back body.
Heat exchanger fixing holder
Screw
Fix Evaporator (DN)
5) Remove right side of the end plate from two fixing rib while sliding slightly the heat exchanger rightward.
Rib on the right side of the end plate
57
FILE NO. Part name Bearing base Procedures 1) Follow to the procedure in the item , , . 2) Remove the two screws used to secure the bearing base.
Two screws
Remarks
3) Remove the bearing base. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG 75286
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.