[. . . ] ENGLISH ITALIANO ESPAÑOL FRANÇAIS DEUTSCH PORTUGUESE §§¡
LG
Indoor Unit (2 Series)
Type: Floor Standing Concealed Floor Standing
OPERATING TEMPERATURE(°C) COOLING MODE INDOOR OUTDOOR MAX. 32°C 21°C 43°C 21°C HEATING MODE INDOOR OUTDOOR MAX. 27°C 20°C 24°C 1°C
DUTCH
IMPORTANT
· Please read this owner's manual carefully and thoroughly before installing and operating your room air conditioner. · Please retain this owner's manual for future reference after reading it thoroughly.
êìëëäàâ üáõä
Floor Standing Concealed Floor Standing Type Indoor Unit Owner's Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions. . . . . . . . . . . . . . . . . 3 Prior to Operation . . . . . . . . . . . . . . . . . . 6 Operating Instructions. . . . . . . . . . . 7 Name and Function of Remote Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Maintenance and Service . . . . . . 9 Before you Call for Service. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. [. . . ] Take care to ensure that nobody could step on or fall onto the outdoor unit. · This could result in personal injury and product damage.
4
Indoor Unit
Safety Precautions
I Installation
Always check for gas (refrigerant) leakage after installation or repair of product. · Low refrigerant levels may cause failure of product. Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. · It may cause a problem for your neighbors.
CAUTION
Install the drain hose to ensure that water is drained away properly. · A bad connection may cause water leakage. Use two or more people to lift and transport the product. Keep level even when installing the product. · To avoid vibration or water leakage. Do not install the product where it will be exposed to sea wind (salt spray) directly. · It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient operation. Do not block the inlet or outlet of air flow.
ENGLISH
I Operation
Do not expose the skin directly to cool air for long periods of time. (Don't sit in the draft. ) Do not use the product for special purposes, such as preserving foods, works of art, etc. It is a consumer air conditioner, not a precision refrigeration system. · There is risk of damage or loss of property. Do not touch the metal parts of the product when removing the air filter. · There is risk of personal injury.
· This could harm to your health.
· It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc. · There is risk of fire, electric shock, or damage to the plastic parts of the product. Clean the filter every two weeks or more often if necessary. · A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. [. . . ] When the air conditioner is to be used again. I Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Turn off the circuit breaker.
CAUTION CAUTION
Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire.
Helpful information
The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ARNU07GCEA2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.