Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG ARNU07GTUC2. We hope that this LG ARNU07GTUC2 user guide will be useful to you.
Lastmanuals help download the user guide LG ARNU07GTUC2.
You may also download the following manuals related to this product:
LG ARNU07GTUC2 ANNEXE 184 (1318 ko)
Manual abstract: user guide LG ARNU07GTUC2
Detailed instructions for use are in the User's Guide.
[. . . ] ENGLISH ITALIANO ESPAÑOL FRANCAIS DEUTSCH PORTUGUÊS
OWNER'S MANUAL
AIR CONDITIONER
Please read this manual carefully before operating your set and retain it for future reference.
TYPE : CEILING CASSETTE - 1WAY (ART TYPE)
NEDERLANDS êìëëäàâüáõä
P/NO : MFL57199103
www. lg. com
Ceiling Cassette - 1Way Type Indoor Unit Owners Manual
TABLE OF CONTENTS
FOR YOUR RECORDS
Safety Precautions. . . . . . . . . . . . . . . . . 3
Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased n Staple your receipt to this page in the event you need it to prove date of purchase or for warranty issues.
Prior to Operation . . . . . . . . . . . . . . . . . . 7
Operating Instructions. . . . . . . . . . . 8
Maintenance and Service . . . . 11 Before you Call for Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. [. . . ] · In case of fresh air intake unit, displays only the temperature around remote controller. Exit button
Some functions may not be operated and displayed depending on the product type. It will display strange value to the room temperature if wired remote controller is not connected.
Model : PQRCVSL0 (Black Color) PQRCVSL0QW (White Color)
8
Indoor Unit
Operating Instructions
ENGLISH
Name and Function of Wireless Remote Controller(Accessory)
1. Plasma button(optional) Used to start or stop the plasma-purification function. Jet cool button Speed cooling operates super high fan speed. If LED indicating filter sign lamp is on, clean the filter. After cleaning the filter, press the timer button and button of wired remote controller at the same time for 3 seconds. Then filter sign LED is off.
10
Indoor Unit
Maintenance and Service
ENGLISH
Maintenance and Service(Robot + Panel Type)
CAUTION
Before performing any maintenance, turn off the main power to the system.
Panel, Case, and Remote Control
o Turn the system off before cleaning. Do not use bleach or abrasives.
Air outlet
NOTICE
Supply power must be disconnected before cleaning the indoor unit.
Air inlet
Remote Controller
TEMP
Wired remote controller
Clean boy
Please sweep clean boy every five years or it is required.
Front panel Suction motor Clean boy
1. Open the cap, dump out dust and then wash clean boy. After drying, push up clean boy until clicking sound. Reassemble right cover.
Right cover
Handle Button
n Never use any of the followings: · Water hotter than 40°C. Could cause deformation and/or discoloration. Be Could damage the nzene surfaces of the air conditioner.
SI
N NE R
S C OU RING C L BA RGER
Owners Manual 11
Maintenance and Service
Maintenance and Service(Standard + Panel Type)
CAUTION
Before performing any maintenance, turn off the main power to the system.
Panel, Case, and Remote Control
o Turn the system off before cleaning. Do not use bleach or abrasives.
Air outlet
NOTICE
Supply power must be disconnected before cleaning the indoor unit.
Air inlet
Remote Controller
TEMP
Wired remote controller
Air Filter
The air filters behind the front grille should be checked and cleaned once every 2 weeks or more often if neccessary. n Take hold of the tab and pull slightly forward to remove the filter.
Air filter
CAUTION
When the air filter is to be removed, do not touch the metal parts of the indoor unit. Clean dirt from the air filter using a vacuum cleaner or washing with water. n If dirt is conspicuous, wash with a neutral detergent in lukewarm water. n If hot water (50°C or more) is used, it may be deformed. n Never use any of the followings: · Water hotter than 40°C. Could cause deformation and/or discoloration. Could damage the surfaces of the air SI N NE R conditioner.
Be
3. [. . . ] Dirt may collect and may cause a fire.
Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Helpful information
The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted.
Check that the ground wire is connected correctly. It may be connect to the indoor unit side.
Operation Tips
Do not overcool the room. Do not let direct sunshine enter the room when the air conditioner is in operation. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ARNU07GTUC2
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG ARNU07GTUC2 will begin.