[. . . ] · Use a circuit breaker or fuse with correct rating. · Install the unit to a proper place that it will not be damaged due to a storm, typhoon or an earthquake. · Do not install the unit on a damaged installation pad. · Do not charge the unit with refrigerant other than the refrigerant specified on the unit during the installation or transportation of the unit. [. . . ] · Ensure that the installation area is not deteriorated in time. OPERATION · Do not make modifications or extensions to power cord. · Always use circuit or breaker dedicated to this unit. · Be careful to prevent water ingress to the unit. · Do not touch (operate) with wet hands. · Do not store or use flammable material or gases in the vicinity of the unit. · Do not put your hand inside the air inlet or outlet during installation of the unit. · Make sure that no one steps on the outer unit or fall on it. · Do not put your hand or other things inside the air inlet or outlet during the operation of the unit. 4 | EN 2 Technical specification ENGLISH ARWN100LA2 Cooling Capacity Heating Capacity Input Power supply Running Current COP Noise level Dimensions (WxHxD) Net Weight Circuit Breaker Cooling Heating Cooling Heating kW kW kW kW Ø/V/Hz A _ _ dB(A) mm kg A 28. 0 31. 5 5. 6 5. 8 3/380 - 415/50 2. 5 ~ 20. 2 5. 0 5. 43 51 772x1, 120x547 163 30 ARWN200LA2 56. 0 63. 0 11. 2 11. 7 3/380 - 415/50 2. 5 ~ 31. 8 5. 0 5. 38 51 772x1, 120x547 223 40 ARWB100LA2 28. 0 31. 5 5. 6 5. 8 3/380 - 415/50 2. 5 ~ 20. 2 5. 0 5. 43 51 772x1, 120x547 163 30 ARWB200LA2 56. 0 63. 0 11. 2 11. 7 3/380 - 415/50 2. 5 ~ 31. 8 5. 0 5. 38 51 772x1, 120x547 223 40 Notes: 1. Capacities and Inputs are based on the following conditions Cooling : Indoor temp. 27°C [80. 6°F]DB/19°C[66. 2°F]WB Water inlet temp. 30°C[86°F] Heating : Indoor temp. 20°C[68°F] * Interconnecting Piping Length 7. 5m (25 ft. ) * Level Difference of Zero 2. Due to our policy of innovation some specifications may be changed without notification 4. Add an anti freeze to circulation water when outside units is operating under 10°C(50°F), and change the DIP switch on main PCB. n Dip switch setting * Use this mode when temperature of circulation inlet water is under 10°C, You should use an anti freeze 5 | EN 3 Practical and Useful Information Do not overcool your room. This may cause health issues, and also it causes excessive power consumption. Keep all doors and windows closed whenever possible to keep the cool air inside the room. Prevent direct sunlight entering the room and keep the blinds and curtains closed when the air conditioner is operated. Clean the air filters regularly. Blockage in the air filter decreases air flow, cooling and dehumidification. If you do not clean air filters regularly, cooling capacity will be lowered and some of the energy you use will be wasted. Ensure that the room temperature and air flow is distributed homogeneously inside the room by adjusting the directions of the vertical and horizontal flaps of your air conditioner. Ventilate the room by opening the windows as possible, since the windows are kept closed during the operation of your air conditioner. Using air curtains on wide and large areas that the doors are kept open all the time, for example in cafeterias, patisseries etc. , will allow using your air conditioner more efficiently by reducing the electric consumption. Then, the room shall reach the desired temperature more quickly. If you will not use air conditioner for a long time, operate it in the fan position for 2 to 3 hours; this will remove the humidity inside the air conditioner. [. . . ] When the heat exchanger elements get dirty, your air conditioner will operate more to provide the required cooing/heating, thus your energy consumption will be increased. Therefore, we advise you to have your air conditioner maintained at least once a year. (Annual maintenance is out of warranty coverage. ) 11. You may lower your energy consumption by using the programming function of air conditioner. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG ARWN100LA2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG ARWN100LA2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag