Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG B120AH NV0. We hope that this LG B120AH NV0 user guide will be useful to you.
Lastmanuals help download the user guide LG B120AH NV0.
Detailed instructions for use are in the User's Guide.
[. . . ] ENGLISH
LG Large Duct-Type Air Conditioner
OWNER'S MANUAL
LG
ITALIANO ESPAÑOL
IMPORTANT
Please read through this manual. It contains valuable information about your air conditioner. This manual may help save time and money by explaining proper product maintenance and preventing improper use.
FRANÇAIS
PRECAUTIONS
Pay close attention to precautions in order to prevent potential hazards and damage from misuse or improper installation. LG is not responsible for any damages caused by misuse of the product.
DEUTSCH
Prior to installation, this air-conditioning unit must be submitted for approval by the utility service which provides electricity (EN 61000-3 Norm. )
Large Duct Type Air Conditioner Owner's Manual
TABLE OF CONTENTS
Safety Precautions. . . . . . . . . . . . . . . . . . . . . . . . . 3
FOR YOUR RECORDS
Write the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. [. . . ] Fan Speed Button Used to set desired fan speed. Operation Mode Selection Button Used to select the operation mode. · Heating Operation Mode. (except cooling model) 7. Timer Cancel Button Used to cancel the timer. Timer Set Button Used to set the timer when the desired time is obtained.
Display temperature can be different from actual room temperature if the remote controller is installed at the place where sun-rays are falling directly or the place nearby heat source.
8 Large Duct-Type Air Conditioner
Operating Instructions
Set the Current Time and a day of the Week
1
Press the '
Hour
' button.
ENGLISH
Each time the button is pressed, the number is changed from 00 to 23. You can set the number of the current hour.
AUTO SWING OPERATION SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
Hour
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
On Off Set no. Time 01
2
Press the '
Min
' button.
Each time the button is pressed, the number is increased from 00 to 59. Time 01
4
Press the Program button again to finish weekly programmining.
Program
10 Large Duct-Type Air Conditioner
Operating Instructions
Holiday Setting
If Tuesday is a holiday in this week, you may set a holiday.
AUTO SWING OPERATION SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
1
Press the Program button.
Program
Timer
Operation unit
03 05 07 On Off Set no. Time 01
Time
Program set
09 11 13
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
ENGLISH
15
AUTO SWING
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
Week
2
Press the Week button. Select Tuesday.
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
On Off Set no. Time 01
AUTO SWING
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
Holiday
3
Press the Holiday button.
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
On Off Set no. Time 01
Then the remote controller will display ' The outside rectangular means holiday.
'.
You cannot set the weekly program for a holiday.
4
Press the Program button again to finish holiday setting.
Timer Setting
This function is used to set either ON or Off interval once in 24 hrs since the setting was done. The unit will automatically operate as per the settings.
Timer
1 2
Press the Timer button.
Hour Min
Using Hour & Min buttons, change the timer setting until the desired time is set.
AUTO SWING OPERATION SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
e. g. The unit is turned off after 5 hrs
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
On Off Set no. Time 01
Cancel
3
If you want to cancel the timer setting, press the Cancel button.
Auto Restart Function
In case the power comes on again after a power failure, Auto Restarting Operation function automatically operates the unit to the previous operating conditions.
Owner's Manual 11
Operating Instructions
Operation Cycle
(Heat Pump Model)
Cooling Mode
(Cooling Model)
Cooling Mode
Soft Dry Mode
Soft Dry Mode
Heating Mode
Auto Mode
Auto Mode
Operation Procedure
1st
On/Off Button
AUTO SWING OPERATION SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
2ndF Timer
On Off Set no. Time 01
Time
AUTO Heater Preheat JET Defrost Humidify SLo Filter Out door ZONE 1234
17 19 21 23
Operation unit No Func Program set
03 05 07 09 11 13 15
2nd
Operation Mode Selection Button
3 1
Timer Cancel 2ndF
3rd
Room Temperature Setting Button
Program
Week
Holiday
PLASMA
AUTO
2 4
Set/Clr Hour Min
RESET
4th
Indoor Fan Speed Selection Button
12 Large Duct-Type Air Conditioner
Operating Instructions
Operation Mode
1 2
Press the On/Off Button.
ENGLISH
Select the desired Operation. Press the Operation Mode Selection Button. Each time the button is pressed, the operation mode is shifted as shown in the arrow direction.
Operation Display
AUTO SWING OPERATION SET TEMP
Room Temp
FAN SPEED HI MED LO
AUTO SWING SUB FUNCTION
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION AUTO SWING
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION AUTO SWING
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
Timer
Operation unit
03 05 07 17 19 On Off 21 Set no. Time 01 23
Time
Program set
09 11 13
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
Timer
Operation unit
03 05 07 17 19 On Off 21Set no. Time 01 23
Time
Program set
09 11 13
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
Timer
Operation unit
03 05 07 17 19 On Off 21Set no. Time 01 23
Time
Program set
09 11 13
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
On Off Set no. Time 01
15
15
15
Cooling Operation
Soft Dry Operation
Heating Operation
Auto Operation
Auto Operation (Cooling Only Model) Auto Changeover (Heat Pump Model)
Cooling/Heating Operation Mode
3
Set the desired temperature.
AUTO SWING
OPERATION
SET TEMP
Room Temp
FAN SPEED HI MED LO
SUB FUNCTION
Time Timer
Operation unit
03 05 07
AUTO Heater Preheat JET Defrost Humidify Filter Out door ZONE 1234
17 19 21 23
Program set
09 11 13 15
Cooling Mode Setting temperature range is 18~30°C Heating Mode Setting temperature range is 16~30°C
On Off Set no. [. . . ] Air outlet vents
Note: Dirty or clogged coils will reduce the operating efficiency of the system and cause higher operating costs.
Air intake vents
Piping
Owner's Manual 17
Care and maintenance
When the air conditioner is not going to be used for a long time.
When air conditioner is not going to be used for a long time.
1
Operate the air conditioner on Air circulation mode for 2 to 3 hours. · This will dry out the internal parts.
2 Turn off the circuit breaker.
CAUTION: Turn off the circuit breaker when the air conditioner is not going to be used for a long time. Dirt may collect and may cause a fire.
When the air conditioner is to be used again.
Check that the air inlet and outlet of the indoor/outdoor unit are not blocked.
Helpful information
The air filters and your electiric bill. If the air filters become clogged with dust, the cooling capacity will drop, and 6% of the electricity used to operate the air conditioner will be wasted.
Operation Tips
Do not overcool the room.
This is not good for the health and wastes electricity.
Keep blinds or curtains closed.
Do not let direct sunshine enter the room when the air conditioner is operation.
Make sure that the doors and windows are shut tight.
Avoid opening doors and windows as much as possible to keep the cool air in the room.
Clean the air filter regularly.
Blockages in the air filter reduce the airflow and lower cooling and dehumidifying effects. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG B120AH NV0
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG B120AH NV0 will begin.