[. . . ] mm) Sound pressure level(Note 2) (High/Mid/Low) PMV Kit (dB(A)) 36/32/28 37/33/28
25 (Polyvinyl choride tube) 37/33/29 Available 40/35/30 44/39/34
A-55
1. Specifications
Compact 4-way Cassette (600 x 600) Type
Model name Cooling/Heating capacity (Note 1) Power supply Running current Power consumption Starting current Main unit Appearance Ceiling Panel Model Panel color Height Main unit Width Depth Outer dimension Ceiling panel Height Width Depth Main unit Total weight Ceiling panel Heat exchanger Soundproof/Heat-insulating material Fan Fan unit Standard air flow (High/Mid/Low) Motor Air filter Controller Gas side Connecting pipe Liquid side (mm) (mm)
O 9. 5 / O 6. 4 /
60Hz
MMU(kW)
AP0071MH 2. 2/2. 5
AP0091MH 2. 8/3. 2
AP0121MH 3. 6/4. 0
AP0151MH 4. 5/5. 0
AP0181MH 5. 6/6. 3
1 phase 60Hz 220V (Separate power supply for indoor units is required. ) (A) (kW) (A) 0. 27 0. 034 0. 49 0. 29 0. 036 0. 52 0. 30 0. 038 0. 54 0. 33 0. 041 0. 59 0. 41 0. 052 0. 73
Electrical characteristics
Zinc hot dipping steel plate *Heat-insulating material attached to only upper plate RBC-UM11PG(W)E Moon white (Munsell/2. 5GY 9. 0/0. 5) 268 575 575 27 700 700 17 3 Finned tube
(mm) (mm) (mm) (mm) (mm) (mm) (kg) (kg)
Non-flammble insulation Turbo fan (m3/h)
552/462/378
570/468/378
594/504/402 60 Long life filter Remote controller
660/552/468
762/642/522
(W)
O 12. 7 /
Drain port (Nominal dia. [. . . ] mm) Sound pressure level(Note 2) (High/Mid/Low) PMV Kit (dB(A)) 36/32/28 37/33/28
23 (Polyvinyl choride tube) 37/33/29 40/35/30 44/39/34
Available
A-56
2. Dimension
Compact 4-way Cassette (600 x 600) Type (MMU-AP***MH)
Bottom face of ceiling
105 93
For bracch duct knockout square hole O150 / Bottom face of ceiling O162 / Electric parts box
145. 5
70. 5
207 175 Knockout for flesh air intake O100 / 149 29 64
235
105
235
575 unit external dimension
595 to 660 ceiling open dimension
575 unit external dimension
700 Panel external dimension
525 hanging bolt pitch
320. 5
Model name
MMU-AP0071MH MMU-AP0091MH CC270TW MMU-AP0151MH MMU-AP0181MH
Refrigerant pipe (Gas) 0151, 0181MH. . . . . . . . . . . . . . . . . O 9. 5 / Refrigerant pipe (Liquid) O6. 4 /
177 525 hanging bolt pitch 595 to 660 ceiling open dimension 700 Panel external dimension 97. 5 214 105 42 148 256 O162 /
331. 5
4-way air Discharge Cassete Type
Arialb1i0c0p34;LG CARRIER CORPORATION
Hanging bolt M10 or W3/8 local arrange Drain discharge port
105 70. 5
190. 5
193. 5
93
55
145. 5
134
63
220. 5
268
For branch duct knockout square hole O150 /
142
Ceiling panel
27
Wiring connection port
21 158
120
Bottom face of ceiling
300
Indoor unit
595 to 660 ceiling open dimension
Bottom face Drain-up standing-up size of ceiling
Stand-up 827. 5 or less Stand-up 850 or less
(NOTE) As ABS is used for the drain discharge port of the main unit, the vinyl chloride paste cannot be used. Use the flexible hose (Band fix) included in the package.
368. 5
64
142
Check port ( 450)
1000 or more
15 or more
595 to 660 ceiling open dimension
Wired remote controller RBC-AMT31E Simple wired remote controller RBC-AS21E2
Wireless remote controller kit TCB-AX21E2 Weekly timer application RBC-AMT31E and RBC-EXW21E2
Obustacle
Space required for installation and servicing
Note: All dimensions are in mm.
A-57
15 or more
1000 or more
1000 or more
200
3. Electrical current characteristics
Compact 4-way Cassette (600 x 600) Type
A-58
4. Fresh air intake (Design guide)
Compact 4-way Cassette (600 x 600) Type Caution
The fresh air shall be conditioned by a heat reclaim ventilator or similar. Ensure the fresh air volume is determined so that mixed suction air and fresh air can maintain the operating temperature. *1. Recommended conditioned air temperature is 12 oC to 30 oC. However, Make a fresh air volume within 20% of standard.
Model name Standard air flow MMU(m3/h) AP0071MH 552 AP0091MH 570 AP0121MH 594 AP0151MH 660 AP0181MH 762
Install a filter within the fresh air duct. (Fresh air does not pass through the filter of Indoor unit. ) Insulate the fresh air duct. [. . . ] (Fresh air does not pass through the filter of Indoor unit. ) Insulate the fresh air duct. Electrically connect the fan of the Heat exchanger unit and the Indoor unit to a single isolator.
300 250
Static Pressure (Pa)
200 150 100 50 0
0
2
4
6
8 10 12 14 Fresh Air Volume (m3/h)
16
18
20
22
Indoor unit
Duct fan motor
Fresh Air Volume
Flange Option :
_
Inter - lock circuit
Connect the driving relay of the duct fan(DC 12V) between 1 and 6 on the indoor P. C. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE LG CC270TW
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.