User manual LG DK182

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual LG DK182. We hope that this LG DK182 user guide will be useful to you.

Lastmanuals help download the user guide LG DK182.


Mode d'emploi LG DK182
Download
Manual abstract: user guide LG DK182

Detailed instructions for use are in the User's Guide.

[. . . ] PARTS REPLACEMENT 10-1 Indoor Unit 10-2 Outdoor Unit 11. EXPLODED VIEWS AND PARTS LIST 11-1 11-2 11-3 11-4 11-5 11-6 Indoor Unit (E-Parts Assy) Indoor Unit Outdoor Unit (RAS-13UAH-ES2, RAS-13UAH-AS2) Outdoor Unit (RAS-10UAH-ES2, RAS-10UAH-AS2) Outdoor Unit (RAS-13UA-ES2, RAS-13UA-AS2) Outdoor Unit (RAS-10UA-ES2, RAS-10UA-AS2) · This air conditioner is charged with HFC (R410A) that doesn't deplete the Ozone layer. · This air conditioner requires special installation for the refrigerant R410A. ­2­ FILE NO. SPECIFICATIONS MODEL ITEM Capacity 220V kW Phase Power source Power consumption Power factor Running current Indoor Outdoor V Hz kW % A A A lit/h dB dB kg mm mm 49 51 1. 00 Capillary tube 12. 7 Flare connection 6. 35 Flare connection m m DK182, AS2 Height Dimensions Net weight Evaporator type Indoor fan type High fan Air volume Medium fan Low fan Fan motor output Air filter OUTDOOR UNIT Height Dimensions Net weight Condenser type Outdoor fan type Airflow volume Fan motor output Compressor Safety device Louver type Usable outdoor temperature range °C 15 ~ 43 Model Output W m /h W 3 DK182, AS2 RAS-13UAH-ES2, AS2 Cooling 240V 3. 60 220V 4. 20 1 220 ­ 240 50 1. 10 98 4. 95 1. 12 97 4. 65 27 2. 0 41/35/31 49 R410A 51 1. 14 97 0. 15 5. 20 4. 95 1. 18 96 3. 60 Heating 240V 4. 26 RAS-13UKP-ES2, AS2 RAS-13UA-ES2, AS2 Cooling 220V 3. 75 240V 3. 75 1. 13 98 5. 10 28 1. 17 97 4. 90 Starting current Moisture removal Noise Refrigerant Indoor (H/M/L) Outdoor (220-240V) Name of refrigerant Rated amount Gas side size Connection type Liquid side size Interconnection Connection type pipe Maximum length (One way) Maximum height difference INDOOR UNIT 49 0. 97 50 Refrigerant control 15*1 6 RAS-13UKP-ES2, AS2 275 790 208 10 Finned tube Cross flow fan mm mm mm kg Width Depth m3/h m /h m3/h W 3 630 520 430 650 550 490 20 Honeycomb woven filter with PP frame RAS-13UAH-ES2, AS2 630 520 430 RAS-13UA-ES2, AS2 550 780 270 mm mm mm kg 40 Width Depth 37 Finned tube Propeller fan 2120 2200 2120 42 2200 2120 2200 PA150X2T-4FM1 1100 Fuse, Overload relay Automatic louver ­10 ~ 24 15 ~ 43 ­3­ FILE NO. [. . . ] How to remove the drains cap Clip drain cap by needle-nose plier, and pull out. Fig. 8-4-17 CAUTION Firmly insert the drain hose and drain cap; otherwise, water may leak. <In case of right or left piping> · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Fig. 8-4-14 How to install the drain hose Firmly insert drain hose connecting part until hitting on a heat insulator. Slit Fig. 8-4-18 <In case of bottom right or bottom left piping> Heat insulator · After scribing slits of the front panel with a knife or a making-off pin, cut them with a pair of nippers or an equivalent tool. Drain hose Fig. SVM-03001 <Left-hand connection with piping> 8-4-6. Indoor unit fixing Bend the connecting pipe so that it is laid within 43 mm 1. Pass the pipe through the hole in the wall, and hook above the wall surface. If the connecting pipe is laid the indoor unit on the installation plate at the upper exceeding 43 mm above the wall surface, the indoor hooks. Swing the indoor unit to right and left to confirm that connecting pipe, make sure to use a spring bender so it is firmly hooked up on the installation plate. While pressing the indoor unit onto the wall, hook it at the lower part on the installation plate. Put water in the drain pan and make sure that the water is drained out of doors. When connecting extension drain hose, insulate the connecting part of extension drain hose with shield pipe. Shield pipe CAUTION 1. Install the outdoor unit without anything blocking the air discharging. When the outdoor unit is installed in a place exposed always exposed to strong wind like a coast or on a high storey of a building, secure the normal fan operation using a duct or a wind shield. In particularly windy areas, install the unit such as to avoid admission of wind. Installation in the following places may result in trouble. · A saline-place such as the coast. · A place where high-frequency waves are likely to be generated as from audio equipment, welders, and medical equipment. Drain hose Inside the room Extension drain hose Fig. 8-4-24 CAUTION Arrange the drain pipe for proper drainage from the unit. Improper drainage can result in dew-dropping. This air conditioner has the structure designed to drain water collected from dew, which forms on the back of the indoor unit, to the drain pan. [. . . ] Fix the cross flow fan with the set screw at the position where the gap between the back body and the right surface of the cross flow fan is 4 mm. 2 2-Screws (R) 2 2-Screws (L) 4 mm 6 Set screw Middle of the fan motor terminal 6 Base bearing 1) Remove the front panel, electrical part, horizontal louver, heat exchanger and the cross flow fan following procedure 5. 2) Remove the 2 screws fixing the base bearing. 3) Remove the bearing from the base bearing. If the housing protrudes from the base bearing, put the housing in position and attach the bearing to the base bearing. 2 2-Screws ­ 64 ­ FILE NO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE LG DK182

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual LG DK182 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag